[shortdesc] True-RMS accuracy, 1000 V AC/DC, 10 A current range, VFD low-pass filter, 200 kHz frequency, CAT III 1000 V/CAT IV 600 V [/shortdesc]
[properties]
| Model |
Fluke 87V |
| Product Type |
Industrial Digital Multimeter |
| True RMS |
Yes |
| Maximum Voltage (AC/DC) |
1000 V |
| Maximum Current (AC/DC) |
10 A (20 A for 30 sec) |
| Resistance Range |
Up to 50 MΩ |
| Capacitance Range |
Up to 9,999 µF |
| Frequency Range |
Up to 200 kHz |
| Temperature Range |
−200 °C to 1090 °C (probe dependent) |
| Conductance |
Up to 60.00 nS |
| Diode Test Range |
3 V |
| Overvoltage Category |
CAT III 1000 V / CAT IV 600 V |
| Display |
6000 counts (19,999 in high-resolution mode) |
| Backlight |
Two-level bright backlight |
| Power |
9V battery (installed) |
| Battery Life |
~400 hours (without backlight) |
| Operating Temperature |
−20 °C to +55 °C |
| Storage Temperature |
−40 °C to +60 °C |
| Humidity |
0–90% (0–35 °C), 0–70% (35–55 °C) |
| Size (H × W × D) |
201 × 98 × 52 mm (with holster) |
| Weight |
355 g (624 g with holster) |
| Shock Rating |
1 m drop (IEC 61010-1:2001) |
| Vibration |
MIL-PRF-28800 Class 2 |
[/properties]
[specifications]
| DC Voltage |
Max 1000 V; Accuracy ±(0.05% + 1); Resolution 10 µV |
| AC Voltage |
Max 1000 V; Accuracy ±(0.7% + 2) True RMS; AC Bandwidth 20 kHz (LPF enabled); 3 dB @ 1 kHz; Resolution 0.1 mV |
| DC Current |
Max 10 A (20 A for 30 sec); Accuracy ±(0.2% + 2); Resolution 0.01 µA |
| AC Current |
Max 10 A (20 A for 30 sec); Accuracy ±(1.0% + 2) True RMS; Resolution 0.1 µA |
| Resistance |
Range up to 50 MΩ; Accuracy ±(0.2% + 1); Resolution 0.1 Ω |
| Capacitance |
Max 9,999 µF; Accuracy ±(1% + 2); Resolution 0.01 nF |
| Frequency |
Max 200 kHz; Accuracy ±(0.005% + 1); Resolution 0.01 Hz |
| Duty Cycle |
Max 99.9%; Accuracy ±(0.2% per kHz + 0.1%); Resolution 0.1% |
| Temperature Measurement |
−200 °C to 1090 °C (meter); with 80BK probe: −40 °C to 260 °C; Accuracy ±2.2 °C or 2% whichever is greater |
| Conductance |
Up to 60.00 nS; Accuracy ±(1.0% + 10); Resolution 0.01 nS |
| Diode Test |
Range 3 V; Resolution 1 mV; Accuracy ±(2% + 1) |
| Environmental Conditions |
Operating: −20 °C to 55 °C; Storage: −40 °C to 60 °C; Humidity: 0–90% (0–35 °C), 0–70% (35–55 °C); Altitude: 2000 m |
| Safety Approvals |
EN 61010-1 CAT III 1000 V / CAT IV 600 V; CE, CSA, RCM |
| Display Performance |
Digital 6000 counts (4/sec), 19,999 high-res mode; Analog bar graph 32 segments (40/sec) |
[/specifications]
[accesories]
| Included (Standard Package) |
TL75 Test Leads; AC175 Alligator Clips; Holster; 9V Battery (installed); 80BK Temperature Probe |
| Included (87V CAL Version) |
All standard items + Traceable calibration certificate with data |
| Optional Accessories |
Fluke TPAK ToolPak Magnetic Meter Hanger; Fluke TLK-225 SureGrip Master Accessory Set; Fluke CXT80 Extreme Case; Fluke Pack30 Professional Tool Backpack |
[/accesories]
Precision Diagnostics for Demanding Industrial Environments
The Fluke 87V Industrial Multimeter delivers the accuracy and resolution required to troubleshoot motor drives, power distribution panels, automation systems and electromechanical equipment even in noisy, high-energy environments. Its advanced low-pass filter ensures precise measurements on variable frequency drives (VFDs), while Peak Capture functionality identifies fast intermittents down to 250 µs for reliable problem isolation. Built to Fluke’s highest safety standards, the 87V withstands spikes above 8000 V and operates confidently in challenging field conditions.
Key Benefits & Features
-
True-RMS performance: Achieves accurate readings on complex, noisy or non-linear loads common in VFD and automation systems.
-
Low-pass VFD filter: Enables stable, precise voltage measurements on motor drives by filtering high-frequency noise.
-
High-speed peak capture: Detects intermittents as short as 250 µs, essential for monitoring unstable signals.
-
Durable industrial build: Rated CAT III 1000 V and CAT IV 600 V with specially designed shielding that blocks high-energy electrical noise.
-
Enhanced visibility & usability: Features a bright two-level backlight, analog bar graph and Touch Hold for easier field work.
Ideal Use Cases
- Testing and diagnosing variable-frequency motor drives
- Industrial automation maintenance and plant operations
- Power distribution and electrical panel troubleshooting
- Field service in high-energy or high-altitude environments (up to 2000 m operating altitude)
- Precision testing for electromechanical systems
Technical Specifications
-
Voltage Measurement: 1000 V AC/DC (True RMS ±0.7% + 2 AC; ±0.05% + 1 DC)
-
Current Measurement: 10 A (20 A for 30 seconds)
-
Resistance: Up to 50 MΩ
-
Capacitance: Up to 9,999 µF
-
Frequency: Up to 200 kHz (0.01 Hz resolution)
-
Duty Cycle: 0–99.9%
-
Temperature: −200 °C to 1090 °C (meter only)
-
Safety Ratings: CAT III 1000 V, CAT IV 600 V
-
Display: 6000–19,999 counts, analog bar graph
-
Battery Life: Approximately 400 hours (without backlight)