{"product_id":"hpe-aruba-networking-j9777a-2530-8g-switch-94wkn","title":"HPE Aruba Networking J9777A 2530 8G Switch","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\u003cli\u003eManaged, Rack-mountable, 8 x 1G ports, 2 x 1G SFP Uplinks, No PoE (Data Only), Layer 2\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"565\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eProperties\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"365\"\u003eHPE OfficeConnect 2530 J9777A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eDescription\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"365\"\u003eSwitch, managed, 8 x 10\/100\/1000 + 2 x combo Gigabit SFP, desktop, rack-mountable, wall-mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e2530 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEthernet Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" rowspan=\"2\" width=\"200\"\u003eI\/O ports and slots\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"365\"\u003e8 RJ-45 autosensing 10\/100\/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T); Media Type: Auto-MDIX; Duplex: 10BASET\/100BASE-TX: half or full; 1000BASE-T: full only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"365\"\u003e2 dual-personality ports; each port can be used as either an RJ-45 10\/100\/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-Tx; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or as a SFP slot (for use with SFP transceivers) ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eAdditional ports and slots\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"365\"\u003e1 dual-personality (RJ-45 or USB micro-B) serial console port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003eElectrical characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eFrequency\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eVoltage\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e100 - 127 \/ 200 - 240 VAC, rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eCurrent\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMaximum heat dissipation\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"365\"\u003e63 BTU\/hr (66.46 kJ\/hr), (switch only: 63 BTU\/hr)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMaximum power rating\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"365\"\u003e18.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eIdle power\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e13.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eDimension\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e10(w) x 6.28(d) x 1.75(h) in (25.4 x 15.95 x 4.45 cm) (1U height)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e2.0 lb (0.91 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMounting and enclosure\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"365\"\u003eMounts in an EIA standard 19-inch telco rack or equipment cabinet (hardware included)\u003cbr data-mce-fragment=\"1\"\u003eHorizontal surface mounting; Wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003cbr\u003e\u003cbr\u003e[specifications]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"633\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eSpecifications\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e2530-J9777A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eMemory and processor\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eARM9E @ 800 MHz, 128 MB flash; Packet buffer size: 1.5 MB dynamically allocated, 256 MB DDR3 DIMM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\" width=\"633\"\u003ePerformance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e100 Mb Latency\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e\u0026lt; 7.4 µs (LIFO 64-byte packets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003e1000 Mb Latency\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e\u0026lt; 2.6 µs (LIFO 64-byte packets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eThroughput\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eup to 14.8 Mpps (64-byte packets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eSwitching capacity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e20 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eMAC address table size\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e16000 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eManagement\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eIMC - Intelligent Management Center; command-line interface; Web browser; configuration menu;\u003cbr data-mce-fragment=\"1\"\u003eOut-of-band management (serial RS-232C or MicroUSB); IEEE 802.3 Ethernet MIB; Repeater MIB; Ethernet Interface MIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e32°F to 113°F (0°C to 45°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eOperating relative humidity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e15% to 95% @ 104°F (40°C), noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eNonoperating\/Storage temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e-40°F to 158°F (-40°C to 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eNonoperating\/Storage relative humidity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e15% to 90% @ 149°F (65°C), noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eAltitude\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eup to 10,000 ft (3 km)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eAcoustic\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003ePower: 0 dB, Pressure: 0 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eSafety\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eUL 60950-1; CAN\/CSA 22.2 No. 60950-1; EN 60825; IEC 60950-1; EN 60950-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eEmissions\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eFCC Class A; EN 55022\/CISPR-22 Class A; VCCI Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eImmunity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eEN 55024, CISPR 24\u003cbr data-mce-fragment=\"1\"\u003eIEC 61000-4-2\u003cbr data-mce-fragment=\"1\"\u003eIEC 61000-4-3\u003cbr data-mce-fragment=\"1\"\u003eIEC 61000-4-4\u003cbr data-mce-fragment=\"1\"\u003eIEC 61000-4-5\u003cbr data-mce-fragment=\"1\"\u003eIEC 61000-4-6\u003cbr data-mce-fragment=\"1\"\u003eIEC 61000-4-8\u003cbr data-mce-fragment=\"1\"\u003eIEC 61000-4-11\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-3-2, IEC 61000-3-2\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-3-3, IEC 61000-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\" width=\"633\"\u003eTechnical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eGeneral Protocols\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eIEEE 802.1D MAC Bridges\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1p Priority\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1Q VLANs\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1s Multiple Spanning Trees\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1w Rapid Reconfiguration of Spanning Tree\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3 Type 10BASE-T\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3ab 1000BASE-T\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3ad Link Aggregation Control Protocol (LACP)\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3af Power over Ethernet\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3at Power over Ethernet Plus\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3az Energy Efficient Ethernet\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3x Flow Control\u003cbr data-mce-fragment=\"1\"\u003eRFC 768 UDP\u003cbr data-mce-fragment=\"1\"\u003eRFC 783 TFTP Protocol (revision 2)\u003cbr data-mce-fragment=\"1\"\u003eRFC 792 ICMP\u003cbr data-mce-fragment=\"1\"\u003eRFC 793 TCP\u003cbr data-mce-fragment=\"1\"\u003eRFC 826 ARP\u003cbr data-mce-fragment=\"1\"\u003eRFC 854 TELNET\u003cbr data-mce-fragment=\"1\"\u003eRFC 868 Time Protocol\u003cbr data-mce-fragment=\"1\"\u003eRFC 951 BOOTP\u003cbr data-mce-fragment=\"1\"\u003eRFC 1350 TFTP Protocol (revision 2)\u003cbr data-mce-fragment=\"1\"\u003eRFC 1542 BOOTP Extensions\u003cbr data-mce-fragment=\"1\"\u003eRFC 1918 Address Allocation for Private Internet\u003cbr data-mce-fragment=\"1\"\u003eRFC 2030 Simple Network Time Protocol (SNTP) v4\u003cbr data-mce-fragment=\"1\"\u003eRFC 2131 DHCP\u003cbr data-mce-fragment=\"1\"\u003eRFC 3411 An Architecture for Describing Simple Network Management Protocol (SNMP) Management Frameworks\u003cbr data-mce-fragment=\"1\"\u003eRFC 3412 Message Processing and Dispatching for the Simple Network Management Protocol (SNMP)\u003cbr data-mce-fragment=\"1\"\u003eRFC 3413 Simple Network Management Protocol (SNMP) Applications\u003cbr data-mce-fragment=\"1\"\u003eRFC 3414 User-based Security Model (USM) for version 3 of the Simple Network Management Protocol (SNMPv3)\u003cbr data-mce-fragment=\"1\"\u003eRFC 3415 View-based Access Control Model (VACM) for the Simple Network Management Protocol (SNMP)\u003cbr data-mce-fragment=\"1\"\u003eRFC 3416 Protocol Operations for SNMP\u003cbr data-mce-fragment=\"1\"\u003eRFC 3575 IANA Considerations for RADIUS\u003cbr data-mce-fragment=\"1\"\u003eRFC 5905 Network Time Protocol Version 4: Protocol and Algorithms Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eDenial of service protection\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eNetwork DoS Filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eDevice Management\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eRFC 1591 DNS (client)\u003cbr data-mce-fragment=\"1\"\u003eRFC 2576 (Coexistence between SNMP V1, V2, V3)\u003cbr data-mce-fragment=\"1\"\u003eRFC 2579 (SMIv2 Text Conventions)\u003cbr data-mce-fragment=\"1\"\u003eRFC 2580 (SMIv2 Conformance)\u003cbr data-mce-fragment=\"1\"\u003eRFC 3416 (SNMP Protocol Operations v2)\u003cbr data-mce-fragment=\"1\"\u003eRFC 3417 (SNMP Transport Mappings)\u003cbr data-mce-fragment=\"1\"\u003eSSHv1\/SSHv2 Secure Shell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eMIBs\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eRFC 1155 Structure \u0026amp; ID of Mgmt Info for TCP\/IP Internets\u003cbr data-mce-fragment=\"1\"\u003eRFC 1212 Concise MIB Definitions\u003cbr data-mce-fragment=\"1\"\u003eRFC 1213 MIB II\u003cbr data-mce-fragment=\"1\"\u003eRFC 1493 Bridge MIB\u003cbr data-mce-fragment=\"1\"\u003eRFC 2021 RMONv2 MIB\u003cbr data-mce-fragment=\"1\"\u003eRFC 2578 Structure of Management Information Version 2 (SMIv2)\u003cbr data-mce-fragment=\"1\"\u003eRFC 2579 Textual Conventions for SMIv2\u003cbr data-mce-fragment=\"1\"\u003eRFC 2613 SMON MIB\u003cbr data-mce-fragment=\"1\"\u003eRFC 2618 RADIUS Client MIB\u003cbr data-mce-fragment=\"1\"\u003eRFC 2620 RADIUS Accounting Client MIB\u003cbr data-mce-fragment=\"1\"\u003eRFC 2665 Ethernet-Like-MIB\u003cbr data-mce-fragment=\"1\"\u003eRFC 2668 802.3 MAU MIB\u003cbr data-mce-fragment=\"1\"\u003eRFC 2674 802.1p and IEEE 802.1Q Bridge MIB\u003cbr data-mce-fragment=\"1\"\u003eRFC 2737 Entity MIB (Version 2)\u003cbr data-mce-fragment=\"1\"\u003eRFC 2863 The Interfaces Group MIB\u003cbr data-mce-fragment=\"1\"\u003eRFC 4836 Managed Objects for 802.3 Medium Attachment Units (MAU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eIPv6\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eRFC 1981 IPv6 Path MTU Discovery\u003cbr data-mce-fragment=\"1\"\u003eRFC 2460 IPv6 Specification\u003cbr data-mce-fragment=\"1\"\u003eRFC 2464 Transmission of IPv6 over Ethernet Networks\u003cbr data-mce-fragment=\"1\"\u003eRFC 2925 Remote Operations MIB (Ping only)\u003cbr data-mce-fragment=\"1\"\u003eRFC 3315 DHCPv6 (client only)\u003cbr data-mce-fragment=\"1\"\u003eRFC 3484 Default Address Selection for IPv6\u003cbr data-mce-fragment=\"1\"\u003eRFC 3513 IPv6 Addressing Architecture\u003cbr data-mce-fragment=\"1\"\u003eRFC 3596 DNS Extension for IPv6\u003cbr data-mce-fragment=\"1\"\u003eRFC 3810 Multicast Listener Discovery Version 2 (MLDv2) for IPv6\u003cbr data-mce-fragment=\"1\"\u003eRFC 4022 MIB for TCP\u003cbr data-mce-fragment=\"1\"\u003eRFC 4113 MIB for UDP\u003cbr data-mce-fragment=\"1\"\u003eRFC 4251 SSHv6 Architecture\u003cbr data-mce-fragment=\"1\"\u003eRFC 4252 SSHv6 Authentication\u003cbr data-mce-fragment=\"1\"\u003eRFC 4252 SSHv6 Transport Layer\u003cbr data-mce-fragment=\"1\"\u003eRFC 4254 SSHv6 Connection\u003cbr data-mce-fragment=\"1\"\u003eRFC 4291 IP Version 6 Addressing Architecture\u003cbr data-mce-fragment=\"1\"\u003eRFC 4293 MIB for IP\u003cbr data-mce-fragment=\"1\"\u003eRFC 4419 Key Exchange for SSH\u003cbr data-mce-fragment=\"1\"\u003eRFC 4443 ICMPv6\u003cbr data-mce-fragment=\"1\"\u003eRFC 4861 IPv6 Neighbor Discovery\u003cbr data-mce-fragment=\"1\"\u003eRFC 4862 IPv6 Stateless Address Auto-configuration\u003cbr data-mce-fragment=\"1\"\u003eRFC 5095 Deprecation of Type 0 Routing Headers in IPv6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eQoS\/CoS\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eRFC 2474 DiffServ precedence, with 4 queues per port\u003cbr data-mce-fragment=\"1\"\u003eRFC 2475 DiffServ Architecture\u003cbr data-mce-fragment=\"1\"\u003eRFC 2597 DiffServ Assured Forwarding (AF)\u003cbr data-mce-fragment=\"1\"\u003eRFC 2598 DiffServ Expedited Forwarding (EF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eIP Multicast\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eRFC 2236 IGMPv2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eNetwork Management\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eIEEE 802.1AB Link Layer Discovery Protocol (LLDP)\u003cbr data-mce-fragment=\"1\"\u003eRFC 1098 A Simple Network Management Protocol (SNMP)\u003cbr data-mce-fragment=\"1\"\u003eRFC 1155 Structure of Management Information\u003cbr data-mce-fragment=\"1\"\u003eRFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events)\u003cbr data-mce-fragment=\"1\"\u003eRFC 3411 SNMP Management Frameworks\u003cbr data-mce-fragment=\"1\"\u003eRFC 3412 Message Processing and Dispatching for the Simple Network Management Protocol (SNMP)\u003cbr data-mce-fragment=\"1\"\u003eRFC 3413 Simple Network Management Protocol (SNMP) Applications\u003cbr data-mce-fragment=\"1\"\u003eRFC 3414 User-based Security Model (USM) for version 3 of the Simple Network Management Protocol (SNMPv3)\u003cbr data-mce-fragment=\"1\"\u003eRFC 3415 View-based Access Control Model (VACM) for the Simple Network Management Protocol (SNMP)\u003cbr data-mce-fragment=\"1\"\u003eRFC 3418 Management Information Base (MIB) for the Simple Network Management Protocol (SNMP)\u003cbr data-mce-fragment=\"1\"\u003eRFC 5424 Syslog Protocol\u003cbr data-mce-fragment=\"1\"\u003eANSI\/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)\u003cbr data-mce-fragment=\"1\"\u003eSNMPv1\/v2c\/v3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"264\"\u003eSecurity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eIEEE 802.1X Port Based Network Access Control\u003cbr data-mce-fragment=\"1\"\u003eRFC 1492 TACACS+\u003cbr data-mce-fragment=\"1\"\u003eRFC 2138 RADIUS Authentication\u003cbr data-mce-fragment=\"1\"\u003eRFC 2866 RADIUS Accounting\u003cbr data-mce-fragment=\"1\"\u003eSecure Sockets Layer (SSL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003cbr\u003e\u003cbr\u003e[accesories]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"422\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\" width=\"422\"\u003eTransceivers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eJ9054C\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eHPE X121 1G SFP LC SX Transceiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eJ8177C\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eHPE X121 1G SFP LC LX Transceiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eJ4859C\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eHPE X121 1G SFP RJ45 T Transceiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eJ4858C\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eHPE X111 100M SFP LC FX Transceiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\" width=\"422\"\u003eCables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eAJ833A\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eHPE 0.5 m Multimode OM3 LC\/LC Optical Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eAJ834A\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eHPE 1 m Multimode OM3 LC\/LC Optical Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eAJ835A\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eHPE 2 m Multimode OM3 LC\/LC Optical Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eAJ836A\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eHPE 5 m Multimode OM3 LC\/LC Optical Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eAJ837A\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eHPE 15 m Multimode OM3 LC\/LC Optical Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eAJ838A\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eHPE 30 m Multimode OM3 LC\/LC Optical Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eAJ839A\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eHPE 50 m Multimode OM3 LC\/LC Optical Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eQK732A\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eHPE Premier Flex LC\/LC Multi-mode OM4 2 fiber 1m Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eQK733A\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eHPE Premier Flex LC\/LC Multi-mode OM4 2 fiber 2m Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eQK734A\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eHPE Premier Flex LC\/LC Multi-mode OM4 2 fiber 5m Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eQK735A\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eHPE Premier Flex LC\/LC Multi-mode OM4 2 fiber 15m Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eQK736A\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eHPE Premier Flex LC\/LC Multi-mode OM4 2 fiber 30m Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eQK737A\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eHPE Premier Flex LC\/LC Multi-mode OM4 2 fiber 50m Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2\u003eHPE Aruba 2530 8G Switch (J9777A)\u003c\/h2\u003e\n\u003cp\u003eThe HPE Aruba 2530 8G Switch delivers secure, reliable, and energy-efficient connectivity, making it ideal for small businesses and branch offices. Equipped with 8 Gigabit Ethernet ports and 2 dual-personality uplink ports, this fully managed Layer 2 switch offers flexible, high-performance networking. Its fanless design ensures quiet operation, perfect for noise-sensitive environments like offices and classrooms.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 x Gigabit Ethernet Ports:\u003c\/strong\u003e Provides fast, reliable connectivity for various network devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 x Dual-Personality Uplink Ports:\u003c\/strong\u003e Flexible uplink options with support for Gigabit Ethernet or SFP transceivers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLayer 2 Capabilities:\u003c\/strong\u003e Includes VLAN support, QoS, and sFlow for efficient traffic management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFanless Design:\u003c\/strong\u003e Ensures quiet operation, making it suitable for office and educational environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy-Efficient Operation:\u003c\/strong\u003e Compliant with IEEE 802.3az, reducing power consumption during low network activity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Overview:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended for:\u003c\/strong\u003e Small businesses, branch offices, and educational institutions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorts:\u003c\/strong\u003e 8 x 10\/100\/1000 Mbps Gigabit Ethernet ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUplink Modules:\u003c\/strong\u003e 2 x dual-personality uplinks (Gigabit Ethernet or SFP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Capacity:\u003c\/strong\u003e 20 Gbps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForwarding Rate:\u003c\/strong\u003e 14.8 Mpps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManagement:\u003c\/strong\u003e Managed via Aruba Central, AirWave, CLI, Web GUI, SNMP.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy Efficiency:\u003c\/strong\u003e Supports IEEE 802.3az for reduced power consumption.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou can check the related tab for the HPE Aruba 2530 8G Switch (J9777A) datasheet.\u003c\/p\u003e","brand":"HPE Aruba","offers":[{"title":"Default Title","offer_id":48013288210649,"sku":"J9777A-NEW","price":545.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/j9777a_5cd03dc8-5451-4ea6-88f7-7c117a3af266.webp?v=1771853384","url":"https:\/\/www.aloinfo.com.co\/su\/products\/hpe-aruba-networking-j9777a-2530-8g-switch-94wkn","provider":"aloinfousa.com","version":"1.0","type":"link"}