{"product_id":"juniper-ptx1k-72q-dc-ir-router-ya2by","title":"Juniper PTX1K-72Q-DC-IR Router","description":"\u003cdiv class=\"short-hide\" data-mce-fragment=\"1\"\u003e[shortdesc]\n\u003cul data-mce-fragment=\"1\"\u003e\n\n\u003cli data-mce-fragment=\"1\"\u003ePTX1000 3rd generation 72 port DC system for high scale LSR or Peering applications\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n[properties]\n\u003cstyle type=\"text\/css\" data-mce-fragment=\"1\"\u003e\u003c!--\ntd {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\" data-mce-fragment=\"1\"\u003e\n\u003ccolgroup data-mce-fragment=\"1\"\u003e\n\u003ccol width=\"222\" data-mce-fragment=\"1\"\u003e\n\u003ccol width=\"364\" data-mce-fragment=\"1\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Properties\"}' data-mce-fragment=\"1\"\u003eProperties\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Juniper PTX1K-72Q-DC-IR\"}' data-mce-fragment=\"1\"\u003eJuniper PTX1K-72Q-DC-IR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Description\"}' data-mce-fragment=\"1\"\u003eDescription\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"PTX1000 LSR\/Peering system with 72-port 100GbE QSFP28 \/ 72-port 40GbE QSFP+ \/ 288-port 10GbE SFP+ with 4 1600 W DC power supplies, 4 power cables, and 3 fan trays\"}' data-mce-fragment=\"1\"\u003ePTX1000 LSR\/Peering system with 72-port 100GbE QSFP28 \/ 72-port 40GbE QSFP+ \/ 288-port 10GbE SFP+ with 4 1600 W DC power supplies, 4 power cables, and 3 fan trays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Product Family\"}' data-mce-fragment=\"1\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"PTX1000 Series\"}' data-mce-fragment=\"1\"\u003ePTX1000 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Product Type\"}' data-mce-fragment=\"1\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Router\"}' data-mce-fragment=\"1\"\u003eRouter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" data-sheets-value='{\"1\":2,\"2\":\"Port Densities\"}' data-mce-fragment=\"1\"\u003ePort Densities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Max. 10GbE\"}' data-mce-fragment=\"1\"\u003eMax. 10GbE\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":3,\"3\":288}' data-mce-fragment=\"1\"\u003e288\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Max. 40GbE\"}' data-mce-fragment=\"1\"\u003eMax. 40GbE\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":3,\"3\":72}' data-mce-fragment=\"1\"\u003e72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Max. 100GbE \"}' data-mce-fragment=\"1\"\u003eMax. 100GbE\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":3,\"3\":24}' data-mce-fragment=\"1\"\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Dimension (WxHxD)\"}' data-mce-fragment=\"1\"\u003eDimension (WxHxD)\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"17.4 x 3.46 x 31 in (44.2 x 8.8 x 78.7 cm)\"}' data-mce-fragment=\"1\"\u003e17.4 x 3.46 x 31 in (44.2 x 8.8 x 78.7 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Weight (lb\/kg) fully configured\"}' data-mce-fragment=\"1\"\u003eWeight (lb\/kg) fully configured\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"68 lb (31 kg)\"}' data-mce-fragment=\"1\"\u003e68 lb (31 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Rack units\"}' data-mce-fragment=\"1\"\u003eRack units\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"2 U\"}' data-mce-fragment=\"1\"\u003e2 U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Maximum power draw\"}' data-mce-fragment=\"1\"\u003eMaximum power draw\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"1425 W (AC, DC), 4862 BTU\/hr\"}' data-mce-fragment=\"1\"\u003e1425 W (AC, DC), 4862 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Typical power draw\"}' data-mce-fragment=\"1\"\u003eTypical power draw\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"1050 W (AC, DC), 3583 BTU\/hr\"}' data-mce-fragment=\"1\"\u003e1050 W (AC, DC), 3583 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Power\"}' data-mce-fragment=\"1\"\u003ePower\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"4x 1,600 Watt AC\/DC power supply\"}' data-mce-fragment=\"1\"\u003e4x 1,600 Watt AC\/DC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Cooling\"}' data-mce-fragment=\"1\"\u003eCooling\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Front-to-back airflow\\nThree hot-swappable fan modules with redundant fans\"}' data-mce-fragment=\"1\"\u003eFront-to-back airflow\u003cbr data-mce-fragment=\"1\"\u003eThree hot-swappable fan modules with redundant fans\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/properties][specifications]\n\u003cstyle type=\"text\/css\" data-mce-fragment=\"1\"\u003e\u003c!--\ntd {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\" data-mce-fragment=\"1\"\u003e\n\u003ccolgroup data-mce-fragment=\"1\"\u003e\n\u003ccol width=\"383\" data-mce-fragment=\"1\"\u003e\n\u003ccol width=\"382\" data-mce-fragment=\"1\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Specifications\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eSpecifications\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"PTX1K-72Q-DC-IR\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003ePTX1K-72Q-DC-IR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"CPU\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eCPU\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Intel Quad Core Ivy Bridge 2.5 GHz CPU\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eIntel Quad Core Ivy Bridge 2.5 GHz CPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"RAM\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eRAM\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"32 Gb SDRAM\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003e32 Gb SDRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"SSD\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eSSD\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"64Gx2\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003e64Gx2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"System throughput\"}' data-mce-fragment=\"1\"\u003eSystem throughput\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Up to 2.88 Tbps\"}' data-mce-fragment=\"1\"\u003eUp to 2.88 Tbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Forwarding capacity\"}' data-mce-fragment=\"1\"\u003eForwarding capacity\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Up to 2 Bpps\"}' data-mce-fragment=\"1\"\u003eUp to 2 Bpps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Management and Precision Time Protocol (PTP) interfaces\"}' data-mce-fragment=\"1\"\u003eManagement and Precision Time Protocol (PTP) interfaces\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"1 small form-factor pluggable transceiver (SFP\/SFP +) port or PTP Grandmaster\\nFiber (SFP) or 10\/100\/1000BASE-T (RJ-45) Ethernet management port\\nSMB in, SMB out, 10 MHz in, 10 MHz out\\nOne console port\\nUSB 2.0 storage interface\"}' data-mce-fragment=\"1\"\u003e1 small form-factor pluggable transceiver (SFP\/SFP +) port or PTP Grandmaster\u003cbr data-mce-fragment=\"1\"\u003eFiber (SFP) or 10\/100\/1000BASE-T (RJ-45) Ethernet management port\u003cbr data-mce-fragment=\"1\"\u003eSMB in, SMB out, 10 MHz in, 10 MHz out\u003cbr data-mce-fragment=\"1\"\u003eOne console port\u003cbr data-mce-fragment=\"1\"\u003eUSB 2.0 storage interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Total packet buffer\"}' data-mce-fragment=\"1\"\u003eTotal packet buffer\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"24 GB\"}' data-mce-fragment=\"1\"\u003e24 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Latency\"}' data-mce-fragment=\"1\"\u003eLatency\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"As low as 2.5 microseconds within a Packet Forwarding\\nEngine (PFE)\\nAs low as 5.5 microseconds across PFEs\"}' data-mce-fragment=\"1\"\u003eAs low as 2.5 microseconds within a Packet Forwarding\u003cbr data-mce-fragment=\"1\"\u003eEngine (PFE)\u003cbr data-mce-fragment=\"1\"\u003eAs low as 5.5 microseconds across PFEs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Operating temperature\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"32° to 104° F (0° to 40° C)\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003e32° to 104° F (0° to 40° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Storage temperature\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"-40° to 158° F (-40° to 70° C)\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003e-40° to 158° F (-40° to 70° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Operating altitude\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Up to 10,000 ft. (3,048 m) \"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eUp to 10,000 ft. (3,048 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Relative humidity operating\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eRelative humidity operating\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"5 to 90% (noncondensing)\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003e5 to 90% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Relative humidity nonoperating\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eRelative humidity nonoperating\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"5 to 95% (noncondensing)\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003e5 to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Seismic\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eSeismic\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\" Designed to meet GR-63, Zone 4 earthquake requirements\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eDesigned to meet GR-63, Zone 4 earthquake requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Safety\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eSafety\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"CAN\/CSA-C22.2 No. 60950-1 Information Technology\\nEquipmentSafety\\nUL 60950-1 Information Technology EquipmentSafety\\nEN 60950-1 Information Technology EquipmentSafety\\nIEC 60950-1 Information Technology EquipmentSafety (All country deviations)\\nEN 60825-1 Safety of Laser ProductsPart 1: Equipment Classification\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eCAN\/CSA-C22.2 No. 60950-1 Information Technology\u003cbr data-mce-fragment=\"1\"\u003eEquipmentSafety\u003cbr data-mce-fragment=\"1\"\u003eUL 60950-1 Information Technology EquipmentSafety\u003cbr data-mce-fragment=\"1\"\u003eEN 60950-1 Information Technology EquipmentSafety\u003cbr data-mce-fragment=\"1\"\u003eIEC 60950-1 Information Technology EquipmentSafety (All country deviations)\u003cbr data-mce-fragment=\"1\"\u003eEN 60825-1 Safety of Laser ProductsPart 1: Equipment Classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"EMC\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003eEMC\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"47CFR Part 15, (FCC) Class A\\nICES-003 Class A\\nEN 55022 Class A\\nCISPR 22 Class A\\nEN 55024\\nCISPR 24\\nEN 300 386\\nVCCI Class A\\nAS\/NZA CISPR22 Class A\\nKN22 Class A\\nCNS 13438 Class A\\nEN 61000-3-2\\nEN 61000-3-3\\nETSI\\nETSI EN 300 019: Environmental Conditions \u0026amp; Environmental\\nTests for Telecommunications Equipment\\nETSI EN 300 019-2-1 (2000)Storage\\nETSI EN 300 019-2-2 (1999)Transportation\\nETSI EN 300 019-2-3 (2003)Stationary Use at Weatherprotected Locations\\nETSI EN 300 019-2-4 (2003)Stationary Use at NonWeather-protected Locations\\nETS 300753 (1997)Acoustic noise emitted by telecommunications equipment\"}' data-sheets-numberformat='{\"1\":1}' data-mce-fragment=\"1\"\u003e47CFR Part 15, (FCC) Class A\u003cbr data-mce-fragment=\"1\"\u003eICES-003 Class A\u003cbr data-mce-fragment=\"1\"\u003eEN 55022 Class A\u003cbr data-mce-fragment=\"1\"\u003eCISPR 22 Class A\u003cbr data-mce-fragment=\"1\"\u003eEN 55024\u003cbr data-mce-fragment=\"1\"\u003eCISPR 24\u003cbr data-mce-fragment=\"1\"\u003eEN 300 386\u003cbr data-mce-fragment=\"1\"\u003eVCCI Class A\u003cbr data-mce-fragment=\"1\"\u003eAS\/NZA CISPR22 Class A\u003cbr data-mce-fragment=\"1\"\u003eKN22 Class A\u003cbr data-mce-fragment=\"1\"\u003eCNS 13438 Class A\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-3-2\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-3-3\u003cbr data-mce-fragment=\"1\"\u003eETSI\u003cbr data-mce-fragment=\"1\"\u003eETSI EN 300 019: Environmental Conditions \u0026amp; Environmental\u003cbr data-mce-fragment=\"1\"\u003eTests for Telecommunications Equipment\u003cbr data-mce-fragment=\"1\"\u003eETSI EN 300 019-2-1 (2000)Storage\u003cbr data-mce-fragment=\"1\"\u003eETSI EN 300 019-2-2 (1999)Transportation\u003cbr data-mce-fragment=\"1\"\u003eETSI EN 300 019-2-3 (2003)Stationary Use at Weatherprotected Locations\u003cbr data-mce-fragment=\"1\"\u003eETSI EN 300 019-2-4 (2003)Stationary Use at NonWeather-protected Locations\u003cbr data-mce-fragment=\"1\"\u003eETS 300753 (1997)Acoustic noise emitted by telecommunications equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/specifications][accesories]\n\u003cstyle type=\"text\/css\" data-mce-fragment=\"1\"\u003e\u003c!--\ntd {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\" data-mce-fragment=\"1\"\u003e\n\u003ccolgroup data-mce-fragment=\"1\"\u003e\n\u003ccol width=\"149\" data-mce-fragment=\"1\"\u003e\n\u003ccol width=\"271\" data-mce-fragment=\"1\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" data-sheets-value='{\"1\":2,\"2\":\"Accessories\"}' data-mce-fragment=\"1\"\u003eAccessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX1K-72QSCA-UP\"}' data-mce-fragment=\"1\"\u003eS-PTX1K-72QSCA-UP\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"PTX1000 Scale-up Software License to upgrade 72 port system (Base to LSR or LSR to Full IP)\"}' data-mce-fragment=\"1\"\u003ePTX1000 Scale-up Software License to upgrade 72 port system (Base to LSR or LSR to Full IP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX1K-36QSCA-UP\"}' data-mce-fragment=\"1\"\u003eS-PTX1K-36QSCA-UP\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"PTX1000 Scale-up Software License to upgrade 36 port system (Base to LSR or LSR to Full IP)\"}' data-mce-fragment=\"1\"\u003ePTX1000 Scale-up Software License to upgrade 36 port system (Base to LSR or LSR to Full IP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX1K-18QSCA-UP\"}' data-mce-fragment=\"1\"\u003eS-PTX1K-18QSCA-UP\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"PTX1000 Scale-up Software License to upgrade 18 port system (Base to LSR or LSR to Full IP)\"}' data-mce-fragment=\"1\"\u003ePTX1000 Scale-up Software License to upgrade 18 port system (Base to LSR or LSR to Full IP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX1K-UPG-18Q\"}' data-mce-fragment=\"1\"\u003eS-PTX1K-UPG-18Q\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"PTX1000 Software License to add 18 more\\nports to Base system\"}' data-mce-fragment=\"1\"\u003ePTX1000 Software License to add 18 more\u003cbr data-mce-fragment=\"1\"\u003eports to Base system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX1K-UPG18Q-IR\"}' data-mce-fragment=\"1\"\u003eS-PTX1K-UPG18Q-IR\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"PTX1000 Software License to add 18 more\\nports to LSR\/Peering system\"}' data-mce-fragment=\"1\"\u003ePTX1000 Software License to add 18 more\u003cbr data-mce-fragment=\"1\"\u003eports to LSR\/Peering system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"S-PTX1K-UPG18Q-R\"}' data-mce-fragment=\"1\"\u003eS-PTX1K-UPG18Q-R\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"PTX1000 Software License to add 18 more\\nports to Full IP system\"}' data-mce-fragment=\"1\"\u003ePTX1000 Software License to add 18 more\u003cbr data-mce-fragment=\"1\"\u003eports to Full IP system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"JPSU-1600W-DC-AFO\"}' data-mce-fragment=\"1\"\u003eJPSU-1600W-DC-AFO\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"PTX1000 1600 W DC power supply\"}' data-mce-fragment=\"1\"\u003ePTX1000 1600 W DC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"PTX1000-FAN-S\"}' data-mce-fragment=\"1\"\u003ePTX1000-FAN-S\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"PTX1000 Fan\"}' data-mce-fragment=\"1\"\u003ePTX1000 Fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/accesories]\n\u003cp\u003eThe PTX1000 Packet Transport Router provides high-density 10GbE, 40GbE, and 100GbE interfaces for distributed core networks and network applications, meeting the demands of Internet service providers and high-volume content providers.\u003c\/p\u003e","brand":"Juniper","offers":[{"title":"Default Title","offer_id":48013189546201,"sku":"PTX1K-72Q-DC-IR-NEW","price":364173.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/ptx1000_3b115874-9c08-4729-93a5-a2f9cfdb8494.jpg?v=1771851679","url":"https:\/\/www.aloinfo.com.co\/sr\/products\/juniper-ptx1k-72q-dc-ir-router-ya2by","provider":"aloinfousa.com","version":"1.0","type":"link"}