{"product_id":"juniper-ex4600-40f-afi-switch-t5dpt","title":"Juniper EX4600-40F-AFI Switch","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\u003cli\u003eSwitch\u003c\/li\u003e\n\u003cli\u003eL3\u003c\/li\u003e\n\u003cli\u003eManaged\u003c\/li\u003e\n\u003cli\u003e24 x 1 Gigabit SFP\/ 10 Gigabit SFP+ + 4 x 40 Gigabit QSFP+ (breakout compatible)\u003c\/li\u003e\n\u003cli\u003eBack to front airflow\u003c\/li\u003e\n\u003cli\u003eRack-mountable\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n[properties]\n\u003ctable width=\"565\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eProperties\u003c\/td\u003e\n\u003ctd width=\"365\" data-mce-fragment=\"1\"\u003eJuniper EX4600-40F-AFI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eDescription\u003c\/td\u003e\n\u003ctd width=\"365\" data-mce-fragment=\"1\"\u003e24 SFP+\/SFP ports, 4 QSFP+ ports, 2 expansion slots, redundant fans, 2 AC power supplies, 2 power cords, 4-post rack mount kit, and back to front airflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX4600 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEthernet Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eDimensions (HxWxD) Inches\u003c\/td\u003e\n\u003ctd width=\"365\" data-mce-fragment=\"1\"\u003e1.72 x17.36 x 20.48 in (4.37 x 44.09 x 52.02 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd width=\"365\" data-mce-fragment=\"1\"\u003e21.7 lb (9.84 kg) with PSUs and fans installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" width=\"565\" data-mce-fragment=\"1\"\u003eInterface Options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003e1GbE SFP\u003c\/td\u003e\n\u003ctd width=\"365\" data-mce-fragment=\"1\"\u003e24(40) (with 10GbE expansion modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003e10GbE SFP+\u003c\/td\u003e\n\u003ctd width=\"365\" data-mce-fragment=\"1\"\u003e24(40\/72) (with 10GbE expansion modules\/with fixed 40GbE ports using breakout cables)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003e40GbE QSFP+\u003c\/td\u003e\n\u003ctd width=\"365\" data-mce-fragment=\"1\"\u003e4 (12) (with expansion modules)\u003cbr data-mce-fragment=\"1\"\u003e Each fixed QSFP+ port can be configured as a 4x10GbE interface\u003cbr data-mce-fragment=\"1\"\u003e Each QSFP+ port can be configured as a 40 Gbps port\u003cbr data-mce-fragment=\"1\"\u003e USB port\u003cbr data-mce-fragment=\"1\"\u003e Console port\u003cbr data-mce-fragment=\"1\"\u003e 2 management ports: 1 RJ-45 and 1 SFP\u003cbr data-mce-fragment=\"1\"\u003e Supported transceiver and direct attach cable\u003cbr data-mce-fragment=\"1\"\u003e SFP+ 10GbE optical modules\u003cbr data-mce-fragment=\"1\"\u003e SFP+ DAC cables: 1\/3\/5 m direct-attached copper and\u003cbr data-mce-fragment=\"1\"\u003e 1\/3\/5\/7\/10 m active direct-attached copper\u003cbr data-mce-fragment=\"1\"\u003e SFP GbE optical and copper module\u003cbr data-mce-fragment=\"1\"\u003e QSFP+ to SFP+ 10GbE direct attach break-out copper\u003cbr data-mce-fragment=\"1\"\u003e (1\/3 m direct-attached copper cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003ePower Consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" width=\"565\" data-mce-fragment=\"1\"\u003eConfiguration: Fixed 10GbE ports with 10G-USR optics, all ports forwarding (line rate), \u0026lt;10 m\u003cbr data-mce-fragment=\"1\"\u003e 4 fixed 40GbE ports with 40G-SR4 optics\u003cbr data-mce-fragment=\"1\"\u003e 1 4x40GbE QIC card with 4 40G-SR4 optics\u003cbr data-mce-fragment=\"1\"\u003e 1 8x10GbE QIC card with 8 10G-USR optics, all ports forwarding (line rate), \u0026lt;10 m\u003cbr data-mce-fragment=\"1\"\u003e Dual power supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX4600-40F-AFO\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e279 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX4600-40F-AFI\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e285 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX4600-40F-DC-AFO\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e392 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX4600-40F-DC-AFI\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e320 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eAirflow\u003c\/td\u003e\n\u003ctd width=\"365\" data-mce-fragment=\"1\"\u003e-Back-to-front cooling\u003cbr data-mce-fragment=\"1\"\u003e -Redundant variable-speed fans to reduce power draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003ePower Supply and Fan Modules\u003c\/td\u003e\n\u003ctd width=\"365\" data-mce-fragment=\"1\"\u003eDual redundant (1+1) and hot-pluggable power supplies\u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003e 110-240 V single phase AC power\u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003e -36 to -72 V DC power\u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003e Redundant (N+1) and hot-pluggable fan modules for front-to-back and back-to-front airflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/properties]\u003cbr\u003e\u003cbr\u003e[specifications]\n\u003ctable width=\"753\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eSpecifications\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eEX4600-40F-AFI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eSwitching capacity\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e720 Gbps (unidirectional)\/1.44 Tbps (bidirectional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eLayer 2\/Layer 3 throughput (maximum with 64 byte packets)\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e1,071 Mpps (wire speed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eSwitching mode\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eCut-through and store-and-forward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003ePredicted mean time between failures (MTBF)\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e150,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003ePredicted FIT rate\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e4,987\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eRack Installation Kit\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eVersatile four post mounting options for 19-in server rack or datacom rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eMAC addresses per system\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e288,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eVLAN Ids\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e4,091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eNumber of ports per LAG\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eFCoE scale\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eNumber of FCoE VLANs\/FC virtual fabrics: 4,095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eFirewall filters\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eIPv4 unicast routes\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e128,000 prefixes; 208,000 host routes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eIPv4 multicast routes\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e104,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eIPv6 multicast routes\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e52,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eIPv6 unicast routes\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e64,000 prefixes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eAddress Resolution Protocol (ARP) entries\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e48,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eJumbo frame\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e9,216 bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" width=\"753\" data-mce-fragment=\"1\"\u003eSoftware Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eLayer 2 Features\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eSTP—IEEE 802.1D (802.1D-2004)\u003cbr data-mce-fragment=\"1\"\u003e Rapid Spanning Tree Protocol (RSTP) (IEEE 802.1w); MSTP (IEEE 802.1s)\u003cbr data-mce-fragment=\"1\"\u003e Bridge protocol data unit (BPDU) protect\u003cbr data-mce-fragment=\"1\"\u003e Loop protect\u003cbr data-mce-fragment=\"1\"\u003e Root protect\u003cbr data-mce-fragment=\"1\"\u003e RSTP and VSTP running concurrently\u003cbr data-mce-fragment=\"1\"\u003e VLAN—IEEE 802.1Q VLAN trunking\u003cbr data-mce-fragment=\"1\"\u003e Routed VLAN interface (RVI)\u003cbr data-mce-fragment=\"1\"\u003e Port-based VLAN\u003cbr data-mce-fragment=\"1\"\u003e MAC address filtering\u003cbr data-mce-fragment=\"1\"\u003e GRE tunneling\u003cbr data-mce-fragment=\"1\"\u003e QinQ\u003cbr data-mce-fragment=\"1\"\u003e VLAN translation\u003cbr data-mce-fragment=\"1\"\u003e Static MAC address assignment for interface\u003cbr data-mce-fragment=\"1\"\u003e Per VLAN MAC learning (limit)\u003cbr data-mce-fragment=\"1\"\u003e MAC learning deactivate\u003cbr data-mce-fragment=\"1\"\u003e Link Aggregation and Link Aggregation Control Protocol (LACP) (IEEE 802.3ad)\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1AB Link Layer Discovery Protocol (LLDP)\u003cbr data-mce-fragment=\"1\"\u003e MAC notification\u003cbr data-mce-fragment=\"1\"\u003e MAC address aging configuration\u003cbr data-mce-fragment=\"1\"\u003e MAC address filtering\u003cbr data-mce-fragment=\"1\"\u003e Persistent MAC (sticky MAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eLayer 3 Features (IPv4)\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eStatic routing\u003cbr data-mce-fragment=\"1\"\u003e Routing policy\u003cbr data-mce-fragment=\"1\"\u003e Routing protocols (RIP, OSPF, IS-IS, BGP, MBGP)\u003cbr data-mce-fragment=\"1\"\u003e Virtual Router Redundancy Protocol (VRRP)\u003cbr data-mce-fragment=\"1\"\u003e Bidirectional Forwarding Detection (BFD) protocol\u003cbr data-mce-fragment=\"1\"\u003e Virtual router\u003cbr data-mce-fragment=\"1\"\u003e Dynamic Host Configuration Protocol (DHCP) relay\u003cbr data-mce-fragment=\"1\"\u003e Proxy Address Resolution Protocol (ARP)\u003cbr data-mce-fragment=\"1\"\u003e Multicast Features\u003cbr data-mce-fragment=\"1\"\u003e Internet Group Management Protocol (IGMP): v1, v2, v3\u003cbr data-mce-fragment=\"1\"\u003e IGMP snooping: v1, v2, v3\u003cbr data-mce-fragment=\"1\"\u003e IGMP filter\u003cbr data-mce-fragment=\"1\"\u003e PIM-SM\u003cbr data-mce-fragment=\"1\"\u003e Multicast Source Discovery Protocol (MSDP)\u003cbr data-mce-fragment=\"1\"\u003e Security and Filters\u003cbr data-mce-fragment=\"1\"\u003e Secure interface login and password\u003cbr data-mce-fragment=\"1\"\u003e RADIUS\u003cbr data-mce-fragment=\"1\"\u003e TACACS+\u003cbr data-mce-fragment=\"1\"\u003e Ingress and egress filters: Allow and deny, port filters, VLAN filters, and routed filters, including management port filters\u003cbr data-mce-fragment=\"1\"\u003e Filter actions: Logging, system logging, reject, mirror to an interface, counters, assign forwarding class, permit, drop, police, mark\u003cbr data-mce-fragment=\"1\"\u003e SSH v1, v2\u003cbr data-mce-fragment=\"1\"\u003e Static ARP support\u003cbr data-mce-fragment=\"1\"\u003e Storm control, port error deactivate, and autorecovery\u003cbr data-mce-fragment=\"1\"\u003e Control plane denial-of-service (DoS) protection\u003cbr data-mce-fragment=\"1\"\u003e Dynamic ARP inspection (DAI)\u003cbr data-mce-fragment=\"1\"\u003e Sticky MAC address\u003cbr data-mce-fragment=\"1\"\u003e DHCP snooping\u003cbr data-mce-fragment=\"1\"\u003e Filter based forwarding\u003cbr data-mce-fragment=\"1\"\u003e IP directed broadcast traffic forwarding\u003cbr data-mce-fragment=\"1\"\u003e IPv4 over GRE (encap and decap)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eLayer 3 Features (IPv6)\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eStatic routing\u003cbr data-mce-fragment=\"1\"\u003e Routing protocols (RIPng, OSPF v3, IS-IS v6, BGP v6)\u003cbr data-mce-fragment=\"1\"\u003e Virtual Router Redundancy Protocol (VRRP v3)\u003cbr data-mce-fragment=\"1\"\u003e IPv6 CoS (BA, MF classification and rewrite, scheduling based on TC)\u003cbr data-mce-fragment=\"1\"\u003e IPv6 over MPLS LSPs (6PE)\u003cbr data-mce-fragment=\"1\"\u003e IPv6 ping\u003cbr data-mce-fragment=\"1\"\u003e IPv6 traceroute\u003cbr data-mce-fragment=\"1\"\u003e Neighbor discovery protocol\u003cbr data-mce-fragment=\"1\"\u003e Path MTU discovery\u003cbr data-mce-fragment=\"1\"\u003e SNMP, NTP, DNS, RADIUS, TACACS+, AAA\u003cbr data-mce-fragment=\"1\"\u003e Virtual router support for IPv6 unicast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eQuality of Service (QoS)\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eL2 and L3 QoS: Classification, rewrite, queuing\u003cbr data-mce-fragment=\"1\"\u003e Rate limiting:\u003cbr data-mce-fragment=\"1\"\u003e Ingress policing: 1 rate 2 color, 2 rate 3 color\u003cbr data-mce-fragment=\"1\"\u003e Egress policing: Policer, policer mark down action\u003cbr data-mce-fragment=\"1\"\u003e Egress shaping: Per queue, per port\u003cbr data-mce-fragment=\"1\"\u003e 12 hardware queues per port (8 unicast and 4 multicast)\u003cbr data-mce-fragment=\"1\"\u003e Strict priority queuing (LLQ), smoothed deficit weighted round-robin (SDWRR), weighted random early detection (WRED), weighted tail drop\u003cbr data-mce-fragment=\"1\"\u003e 802.1p remarking\u003cbr data-mce-fragment=\"1\"\u003e L2 classification criteria: Interface, MAC address, Ethertype, 802.1p, VLAN\u003cbr data-mce-fragment=\"1\"\u003e Congestion avoidance capabilities: WRED\u003cbr data-mce-fragment=\"1\"\u003e Trust IEEE 802.1p (ingress)\u003cbr data-mce-fragment=\"1\"\u003e Remarking of bridged packets\u003cbr data-mce-fragment=\"1\"\u003e Priority-based flow control (PFC)—IEEE 802.1Qbb\u003cbr data-mce-fragment=\"1\"\u003e Data Center Bridging Exchange Protocol (DCBX), DCBx FCoE, and iSCSI type, length, and value (TLVs)\u003cbr data-mce-fragment=\"1\"\u003e Fibre Channel over Ethernet (FCoE)\u003cbr data-mce-fragment=\"1\"\u003e FCoE transit switch (FIP snooping ACL installation)\u003cbr data-mce-fragment=\"1\"\u003e Virtual fiber channel gateway\u003cbr data-mce-fragment=\"1\"\u003e FCoE session path learning\u003cbr data-mce-fragment=\"1\"\u003e FCoE session health monitoring\u003cbr data-mce-fragment=\"1\"\u003e Graceful restart for FIP snooping\u003cbr data-mce-fragment=\"1\"\u003e FC-BB-6 VN2VN snooping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eAccess Control Lists (ACLs)\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003ePort-based ACL (PACL): Ingress and egress\u003cbr data-mce-fragment=\"1\"\u003e VLAN-based ACL (VACL): Ingress and egress\u003cbr data-mce-fragment=\"1\"\u003e Router-based ACL (RACL): Ingress and egress\u003cbr data-mce-fragment=\"1\"\u003e ACL entries (ACE) in hardware per system:\u003cbr data-mce-fragment=\"1\"\u003e Ingress ACL: 1,536\u003cbr data-mce-fragment=\"1\"\u003e Egress ACL: 1,024\u003cbr data-mce-fragment=\"1\"\u003e ACL counter for denied packets\u003cbr data-mce-fragment=\"1\"\u003e ACL counter for permitted packets\u003cbr data-mce-fragment=\"1\"\u003e Ability to add\/remove\/change ACL entries in middle of list (ACL editing)\u003cbr data-mce-fragment=\"1\"\u003e L2-L4 ACL\u003cbr data-mce-fragment=\"1\"\u003e IPv6 ACL\u003cbr data-mce-fragment=\"1\"\u003e Firewall filter on loopback interface\u003cbr data-mce-fragment=\"1\"\u003e Firewall filter on management interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eVirtual Chassis\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e40GbE and 10GbE as Virtual Chassis port\u003cbr data-mce-fragment=\"1\"\u003e Virtual Chassis Routing Engine (RE) election\u003cbr data-mce-fragment=\"1\"\u003e Virtual Chassis pre-provisioning (plug and play)\u003cbr data-mce-fragment=\"1\"\u003e Auto-LAG formation of Virtual Chassis ports\u003cbr data-mce-fragment=\"1\"\u003e Mixed Virtual Chassis support between EX4300-EX4600 (in data center only)\u003cbr data-mce-fragment=\"1\"\u003e FCoE transit across Virtual Chassis members\u003cbr data-mce-fragment=\"1\"\u003e QoS on Virtual Chassis ports\u003cbr data-mce-fragment=\"1\"\u003e Local designated forwarding\u003cbr data-mce-fragment=\"1\"\u003e Graceful RE switchover (GRES)\u003cbr data-mce-fragment=\"1\"\u003e Nonstop routing (NSR)\u003cbr data-mce-fragment=\"1\"\u003e Nonstop bridging (NSB)\u003cbr data-mce-fragment=\"1\"\u003e Monitor distributed aggregate interface\u003cbr data-mce-fragment=\"1\"\u003e Control plane protection for virtual RE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eHigh Availability\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eISSU (in standalone and MC-LAG configuration)\u003cbr data-mce-fragment=\"1\"\u003e Bidirectional Forwarding Detection (BFD)\u003cbr data-mce-fragment=\"1\"\u003e Uplink failure detection (UFD)\u003cbr data-mce-fragment=\"1\"\u003e Graceful Routing Engine switchover (GRES) in Virtual Chassis configuration\u003cbr data-mce-fragment=\"1\"\u003e Non-stop bridging (NSB) in Virtual Chassis configuration\u003cbr data-mce-fragment=\"1\"\u003e Non-stop routing (NSR) in Virtual Chassis configuration\u003cbr data-mce-fragment=\"1\"\u003e Non-stop software upgrade (NSSU) in Virtual Chassis configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eMPLS\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eVRF-Lite\u003cbr data-mce-fragment=\"1\"\u003e 2-label stack\u003cbr data-mce-fragment=\"1\"\u003e Static label-switched paths (LSPs)\u003cbr data-mce-fragment=\"1\"\u003e RSVP-based signaling of LSPs\u003cbr data-mce-fragment=\"1\"\u003e LDP-based signaling of LSPs\u003cbr data-mce-fragment=\"1\"\u003e LDP tunneling (LDP over RSVP)\u003cbr data-mce-fragment=\"1\"\u003e MPLS class of service (CoS)\u003cbr data-mce-fragment=\"1\"\u003e MPLS access control list (ACL)\/policers\u003cbr data-mce-fragment=\"1\"\u003e MPLS LSR support\u003cbr data-mce-fragment=\"1\"\u003e Push, swap, pop, IP lookup\u003cbr data-mce-fragment=\"1\"\u003e IPv6 tunneling (6PE) (via IPv4 MPLS backbone)\u003cbr data-mce-fragment=\"1\"\u003e MPLS Operation, Administration, and Maintenance (OAM)\u003cbr data-mce-fragment=\"1\"\u003e LSP ping\u003cbr data-mce-fragment=\"1\"\u003e IPv4 L3VPN (RFC 2547, 4364)\u003cbr data-mce-fragment=\"1\"\u003e Ethernet-over-MPLS (L2 circuit)\u003cbr data-mce-fragment=\"1\"\u003e Layer 3 VPN (L3VPN)\u003cbr data-mce-fragment=\"1\"\u003e Layer 2 VPN (L2VPN)\u003cbr data-mce-fragment=\"1\"\u003e Link protection\u003cbr data-mce-fragment=\"1\"\u003e MPLS fast reroute (FRR)- 1:1 Protection\u003cbr data-mce-fragment=\"1\"\u003e Node-link protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eDevice Management and Operations\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eJunos Web Software (J-Web)\u003cbr data-mce-fragment=\"1\"\u003e Role-based CLI management and access\u003cbr data-mce-fragment=\"1\"\u003e CLI via console, telnet, or SSH\u003cbr data-mce-fragment=\"1\"\u003e Extended ping and traceroute\u003cbr data-mce-fragment=\"1\"\u003e Junos OS configuration rescue and rollback\u003cbr data-mce-fragment=\"1\"\u003e Image rollback\u003cbr data-mce-fragment=\"1\"\u003e SNMP v1\/v2\/v3\u003cbr data-mce-fragment=\"1\"\u003e Junos XML management protocol\u003cbr data-mce-fragment=\"1\"\u003e sFlow v5\u003cbr data-mce-fragment=\"1\"\u003e DHCP server\u003cbr data-mce-fragment=\"1\"\u003e DHCP relay on L2 VLAN \u0026amp; L3 interfaces (with option 82)\u003cbr data-mce-fragment=\"1\"\u003e DHCP local server support\u003cbr data-mce-fragment=\"1\"\u003e High frequency statistics collection\u003cbr data-mce-fragment=\"1\"\u003e Beacon LED for port and system\u003cbr data-mce-fragment=\"1\"\u003e Automation and orchestration\u003cbr data-mce-fragment=\"1\"\u003e Zero touch provisioning (ZTP)\u003cbr data-mce-fragment=\"1\"\u003e OpenStack Neutron Plug-in\u003cbr data-mce-fragment=\"1\"\u003e Puppet\u003cbr data-mce-fragment=\"1\"\u003e Chef\u003cbr data-mce-fragment=\"1\"\u003e Junos OS event, commit, and operations scripts\u003cbr data-mce-fragment=\"1\"\u003e Ability to execute scripts written in Python\/TCL\/Perl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eManagement and Analytics Platforms\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eJuniper Mist Wired Assurance for Campus\u003cbr data-mce-fragment=\"1\"\u003e Junos Space®Network Director for Campus\u003cbr data-mce-fragment=\"1\"\u003e Junos Space® Management \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eSpanning Tree Protocol (STP)\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eMultiple Spanning Tree Protocol (MSTP) instances: 64\u003cbr data-mce-fragment=\"1\"\u003e VLAN Spanning Tree Protocol (VSTP) instances: 253\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eLink Aggregation\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eMultichassis link aggregation (MC-LAG) - Layer 2, Layer 3, VRRP, STP\u003cbr data-mce-fragment=\"1\"\u003e Redundant trunk group (RTG)\u003cbr data-mce-fragment=\"1\"\u003e LAG load sharing algorithm—bridged or routed (unicast or multicast) traffic:\u003cbr data-mce-fragment=\"1\"\u003e IP: SIP, Dynamic Internet Protocol (DIP), TCP\/UDP source port, TCP\/UDP destination port\u003cbr data-mce-fragment=\"1\"\u003e Layer 2 and non-IP: MAC SA, MAC DA, Ethertype, VLAN ID, source port\u003cbr data-mce-fragment=\"1\"\u003e FCoE packet: Source ID (SID), destination ID (DID), originator exchange ID (OXID), source port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eTraffic Mirroring\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003ePort-based\u003cbr data-mce-fragment=\"1\"\u003e LAG port\u003cbr data-mce-fragment=\"1\"\u003e VLAN-based\u003cbr data-mce-fragment=\"1\"\u003e Filter-based\u003cbr data-mce-fragment=\"1\"\u003e Mirror to local\u003cbr data-mce-fragment=\"1\"\u003e Local\/L2 remote analyzer (SPAN, RSPAN for IPv4 and IPv6 frames)\u003cbr data-mce-fragment=\"1\"\u003e Mirror to remote destinations (L2 over VLAN)\u003cbr data-mce-fragment=\"1\"\u003e Insight Technology (microburst monitoring and statistics reporting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e32° to 104° F (0° to 40° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e-40° to 158° F (-40° to 70° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eup to 2,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRelative humidity operating\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e5% to 90% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRelative humidity non-operating\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0% to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eIEEE Standards\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eIEEE 802.1D\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1w\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1Q\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1p\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1ad\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.3ad\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1AB\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.3x\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1Qbb\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1Qaz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eSupported RFCs\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eRFC 768 UDP\u003cbr data-mce-fragment=\"1\"\u003e RFC 783 Trivial File Transfer Protocol (TFTP)\u003cbr data-mce-fragment=\"1\"\u003e RFC 791 IP\u003cbr data-mce-fragment=\"1\"\u003e RFC 792 ICMP\u003cbr data-mce-fragment=\"1\"\u003e RFC 793 TCP\u003cbr data-mce-fragment=\"1\"\u003e RFC 826 ARP\u003cbr data-mce-fragment=\"1\"\u003e RFC 854 Telnet client and server\u003cbr data-mce-fragment=\"1\"\u003e RFC 894 IP over Ethernet\u003cbr data-mce-fragment=\"1\"\u003e RFC 903 RARP\u003cbr data-mce-fragment=\"1\"\u003e RFC 906 TFTP Bootstrap\u003cbr data-mce-fragment=\"1\"\u003e RFC 951 1542 BootP\u003cbr data-mce-fragment=\"1\"\u003e RFC 1058 Routing Information Protocol\u003cbr data-mce-fragment=\"1\"\u003e RFC 1112 IGMP v1\u003cbr data-mce-fragment=\"1\"\u003e RFC 1122 Host requirements\u003cbr data-mce-fragment=\"1\"\u003e RFC 1142 OSI IS-IS Intra-domain Routing Protocol\u003cbr data-mce-fragment=\"1\"\u003e RFC 1256 IPv4 ICMP Router Discovery (IRDP)\u003cbr data-mce-fragment=\"1\"\u003e RFC 1492 TACACS+\u003cbr data-mce-fragment=\"1\"\u003e RFC 1519 Classless Interdomain Routing (CIDR)\u003cbr data-mce-fragment=\"1\"\u003e RFC 1587 OSPF not-so-stubby area (NSSA) Option\u003cbr data-mce-fragment=\"1\"\u003e RFC 1591 Domain Name System (DNS)\u003cbr data-mce-fragment=\"1\"\u003e RFC 1745 BGP4\/IDRP for IP—OSPF Interaction\u003cbr data-mce-fragment=\"1\"\u003e RFC 1772 Application of the Border Gateway Protocol in the Internet\u003cbr data-mce-fragment=\"1\"\u003e RFC 1812 Requirements for IP Version 4 routers\u003cbr data-mce-fragment=\"1\"\u003e RFC 1997 BGP Communities Attribute\u003cbr data-mce-fragment=\"1\"\u003e RFC 2030 SNTP, Simple Network Time Protocol\u003cbr data-mce-fragment=\"1\"\u003e RFC 2068 HTTP server\u003cbr data-mce-fragment=\"1\"\u003e RFC 2131 BOOTP\/DHCP relay agent and Dynamic Host\u003cbr data-mce-fragment=\"1\"\u003e RFC 2138 RADIUS Authentication\u003cbr data-mce-fragment=\"1\"\u003e RFC 2139 RADIUS Accounting\u003cbr data-mce-fragment=\"1\"\u003e RFC 2154 OSPF w\/Digital Signatures (Password, MD-5)\u003cbr data-mce-fragment=\"1\"\u003e RFC 2236 IGMP v2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2267 Network ingress filtering\u003cbr data-mce-fragment=\"1\"\u003e RFC 2328 OSPF v2 (edge mode)\u003cbr data-mce-fragment=\"1\"\u003e RFC 2338 VRRP\u003cbr data-mce-fragment=\"1\"\u003e RFC 2362 PIM-SM (edge mode)\u003cbr data-mce-fragment=\"1\"\u003e RFC 2370 OSPF Opaque link-state advertisement (LSA) Option\u003cbr data-mce-fragment=\"1\"\u003e RFC 2385 Protection of BGP Sessions via the TCP Message Digest 5 (MD5) Signature Option\u003cbr data-mce-fragment=\"1\"\u003e RFC 2439 BGP Route Flap Damping\u003cbr data-mce-fragment=\"1\"\u003e RFC 2453 RIP v2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2474 Definition of the Differentiated Services Field in the IPv4 and IPv6 Headers\u003cbr data-mce-fragment=\"1\"\u003e RFC 2597 Assured Forwarding PHB (per-hop behavior) Group\u003cbr data-mce-fragment=\"1\"\u003e RFC 2598 An Expedited Forwarding PHB\u003cbr data-mce-fragment=\"1\"\u003e RFC 2697 A Single Rate Three Color Marker\u003cbr data-mce-fragment=\"1\"\u003e RFC 2698 A Two Rate Three Color Marker\u003cbr data-mce-fragment=\"1\"\u003e RFC 2796 BGP Route Reflection—An Alternative to Full Mesh IBGP\u003cbr data-mce-fragment=\"1\"\u003e RFC 2918 Route Refresh Capability for BGP-4\u003cbr data-mce-fragment=\"1\"\u003e RFC 3065 Autonomous System Confederations for BGP\u003cbr data-mce-fragment=\"1\"\u003e RFC 3376 IGMP v3 (source-specific multicast include mode only)\u003cbr data-mce-fragment=\"1\"\u003e RFC 3392 Capabilities Advertisement with BGP-4\u003cbr data-mce-fragment=\"1\"\u003e RFC 3446 Anycast RP\u003cbr data-mce-fragment=\"1\"\u003e RFC 3569 SSM\u003cbr data-mce-fragment=\"1\"\u003e RFC 3618 MSDP\u003cbr data-mce-fragment=\"1\"\u003e RFC 3623 Graceful OSPF Restart\u003cbr data-mce-fragment=\"1\"\u003e RFC 4271 Border Gateway Protocol 4 (BGP-4)\u003cbr data-mce-fragment=\"1\"\u003e RFC 4360 BGP Extended Communities Attribute\u003cbr data-mce-fragment=\"1\"\u003e RFC 4456 BGP Route Reflection: An Alternative to Full Mesh Internal BGP (IBGP)\u003cbr data-mce-fragment=\"1\"\u003e RFC 4486 Subcodes for BGP Cease Notification Message\u003cbr data-mce-fragment=\"1\"\u003e RFC 4724 Graceful Restart Mechanism for BGP\u003cbr data-mce-fragment=\"1\"\u003e RFC 4812 OSPF Restart Signaling\u003cbr data-mce-fragment=\"1\"\u003e RFC 4893 BGP Support for Four-octet AS Number Space\u003cbr data-mce-fragment=\"1\"\u003e RFC 5176 Dynamic Authorization Extensions to RADIUS\u003cbr data-mce-fragment=\"1\"\u003e RFC 5396 Textual Representation of Autonomous System (AS) Numbers\u003cbr data-mce-fragment=\"1\"\u003e RFC 5668 4-Octet AS Specific BGP Extended Community\u003cbr data-mce-fragment=\"1\"\u003e RFC 5880 Bidirectional Forwarding Detection (BFD)\u003cbr data-mce-fragment=\"1\"\u003e Dynamic Host Configuration Protocol (DHCP) server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eSupported MIBs\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eRFC 1155 SMI\u003cbr data-mce-fragment=\"1\"\u003e RFC 1157 SNMPv1\u003cbr data-mce-fragment=\"1\"\u003e RFC 1212, RFC 1213, RFC 1215 MIB-II, Ethernet-Like MIB, and TRAPs\u003cbr data-mce-fragment=\"1\"\u003e RFC 1850 OSPFv2 MIB\u003cbr data-mce-fragment=\"1\"\u003e RFC 1901 Introduction to Community-based SNMPv2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2011 SNMPv2 for Internet protocol using SMIv2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2012 SNMPv2 for transmission control protocol using SMIv2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2013 SNMPv2 for user datagram protocol using SMIv2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2233, The Interfaces Group MIB using SMIv2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2287 System Application Packages MIB\u003cbr data-mce-fragment=\"1\"\u003e RFC 2570 Introduction to Version 3 of the Internet-standard Network Management Framework\u003cbr data-mce-fragment=\"1\"\u003e RFC 2571 An Architecture for describing SNMP Management Frameworks (read-only access)\u003cbr data-mce-fragment=\"1\"\u003e RFC 2572 Message Processing and Dispatching for the SNMP (read-only access)\u003cbr data-mce-fragment=\"1\"\u003e RFC 2576 Coexistence between SNMP Version 1, Version 2, and Version 3\u003cbr data-mce-fragment=\"1\"\u003e RFC 2578 SNMP Structure of Management Information MIB\u003cbr data-mce-fragment=\"1\"\u003e RFC 2579 SNMP Textual Conventions for SMIv2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2580 Conformance Statements for SMIv2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2665 Ethernet-like interface MIB\u003cbr data-mce-fragment=\"1\"\u003e RFC 2787 VRRP MIB\u003cbr data-mce-fragment=\"1\"\u003e RFC 2790 Host Resources MIB\u003cbr data-mce-fragment=\"1\"\u003e RFC 2819 RMON MIB\u003cbr data-mce-fragment=\"1\"\u003e RFC 2863 Interface Group MIB\u003cbr data-mce-fragment=\"1\"\u003e RFC 2932 IPv4 Multicast MIB\u003cbr data-mce-fragment=\"1\"\u003e RFC 3410 Introduction and Applicability Statements for Internet Standard Management Framework\u003cbr data-mce-fragment=\"1\"\u003e RFC 3411 An architecture for describing SNMP Management Frameworks\u003cbr data-mce-fragment=\"1\"\u003e RFC 3412 Message Processing and Dispatching for the SNMP\u003cbr data-mce-fragment=\"1\"\u003e RFC 3413 Simple Network Management Protocol (SNMP) (all MIBs are supported except the Proxy MIB)\u003cbr data-mce-fragment=\"1\"\u003e RFC 3414 User-based Security Model (USM) for version 3 of SNMPv3\u003cbr data-mce-fragment=\"1\"\u003e RFC 3415 View-based Access Control Model (VACM) for the SNMP\u003cbr data-mce-fragment=\"1\"\u003e RFC 3416 Version 2 of the Protocol Operations for the SNMP\u003cbr data-mce-fragment=\"1\"\u003e RFC 3417 Transport Mappings for the SNMP\u003cbr data-mce-fragment=\"1\"\u003e RFC 3418 Management Information Base (MIB) for the SNMP\u003cbr data-mce-fragment=\"1\"\u003e RFC 3584 Coexistence between Version 1, Version 2, and Version 3 of the Internet-standard Network Management Framework\u003cbr data-mce-fragment=\"1\"\u003e RFC 3826 The Advanced Encryption Standard (AES) Cipher Algorithm in the SNMP User-based Security Model\u003cbr data-mce-fragment=\"1\"\u003e RFC 4188 Definitions of Managed Objects for Bridges\u003cbr data-mce-fragment=\"1\"\u003e RFC 4318 Definitions of Managed Objects for Bridges with Rapid Spanning Tree Protocol\u003cbr data-mce-fragment=\"1\"\u003e RFC 4363b Q-Bridge VLAN MIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eSafety\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eCAN\/CSA-C22.2 No. 60950-1 (2007) Information Technology Equipment—Safety\u003cbr data-mce-fragment=\"1\"\u003e UL 60950-1 (2nd Ed.) Information Technology Equipment—Safety\u003cbr data-mce-fragment=\"1\"\u003e EN 60950-1 (2005) Information Technology Equipment—Safety\u003cbr data-mce-fragment=\"1\"\u003e IEC 60950-1 (2005) Information Technology Equipment—Safety (All country deviations): CB Scheme report.\u003cbr data-mce-fragment=\"1\"\u003e EN 60825-1 +A1+A2 (1994) Safety of Laser Products—Part 1: Equipment Classification\u003cbr data-mce-fragment=\"1\"\u003e GR-63-Core (2006) Network Equipment, Building Systems (NEBS) Physical Protection\u003cbr data-mce-fragment=\"1\"\u003e GR-1089-Core (2006) EMC and Electrical Safety for Network Telecommunications Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eEMC\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eFCC 47CFR, Part 15 Class A (2009) USA Radiated Emissions\u003cbr data-mce-fragment=\"1\"\u003e EN 55022 Class A (2006)+ A1 2007 European Radiated Emissions\u003cbr data-mce-fragment=\"1\"\u003e VCCI Class A (2007) Japanese Radiated Emissions\u003cbr data-mce-fragment=\"1\"\u003e BSMI CNS 13438 and NCC C6357 Taiwan Radiated Emissions\u003cbr data-mce-fragment=\"1\"\u003e AS\/NZS CISPR22:2009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/specifications]\u003cbr\u003e\u003cbr\u003e[accesories]\n\u003ctable width=\"422\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" width=\"422\" data-mce-fragment=\"1\"\u003eModules and Spares\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-EM-4Q\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003e4-port QSFP+ expansion module for EX4600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eEX4600-EM-8F\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003e 8-port SPF+\/SFP expansion module for EX4600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX5100-FAN-AFI\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003e Back-to-front airflow fan module for EX4600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX5100-EM-BLNK\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eBlank module for EX4600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003eSpare Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eEX4600-40F-S\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSpare chassis, 24 SFP+\/SFP ports, 4 QSFP+ ports, 2 expansion slots, redundant fans, front-to-back airflow (optics, power supplies and fans not included and sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" width=\"422\" data-mce-fragment=\"1\"\u003eOptics and Transceivers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eEX-SFP-1GE-T\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP 10\/100\/1000BASE-T Copper Transceiver Module for up to 100 m transmission on Cat5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eEX-SFP-1GE-SX\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP 1000BASE-SX Gigabit Ethernet Optics, 850 nm for up to 550 m transmission on MMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eEX-SFP-10GE-SR\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10GBASE-SR 10-Gigabit Ethernet Optics, 850 nm for up to 300 m transmission on multimode fiberoptic (MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eEX-SFP-10GE-LR\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10GBASE-LR 10-Gigabit Ethernet Optics, 1310 nm for 10 km transmission on single-mode fiber-optic (SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-10GE-USR\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10 Gigabit Ethernet Ultra Short Reach Optics, 850 nm for 10 m on OM1, 20 m on OM2, 100 m on OM3 multimode fiber (MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-10GE-LR\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10GBASE-LR 10 Gigabit Ethernet Optics, 1,310 nm for 10 km transmission on single mode fiber-optic (SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-10GE-ER\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10GBASE-ER 10 Gigabit Ethernet Optics, 1,550 nm for 40 km transmission on single-mode fiber (SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eEX-SFP-10GE-ZR\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10GBASE-ZR 10 Gigabit Ethernet Optics, 1,550 nm for 80 km transmission on single-mode fiber (SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-DAC-1M\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10 Gigabit Ethernet Direct Attach Copper (direct-attached copper cable) 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-DAC-3M\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10 Gigabit Ethernet Direct Attach Copper (direct-attached copper cable) 3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-DAC-5M\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10 Gigabit Ethernet Direct Attach Copper (direct-attached copper cable) 5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-DAC-1MA\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10 Gigabit Ethernet Direct Attach Copper (active direct-attached copper cable) 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-DAC-3MA\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10 Gigabit Ethernet Direct Attach Copper (active direct-attached copper cable) 3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-DAC-5MA\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10 Gigabit Ethernet Direct Attach Copper (active direct-attached copper cable) 5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-DAC-7MA\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10 Gigabit Ethernet Direct Attach Copper (active direct-attached copper cable) 7 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-DAC-10MA\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10 Gigabit Ethernet Direct Attach Copper (active direct-attached copper cable) 10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-QSFP-DAC-1M\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eQSFP+ to QSFP+ Ethernet Direct Attach Copper (direct-attached copper cable) 1 m passive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-QSFP-DAC-3M\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eQSFP+ to QSFP+ Ethernet Direct Attach Copper (direct-attached copper cable) 3 m passive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eJNP-QSFP-DAC-5M\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eQSFP+ to QSFP+ Ethernet Direct Attach Copper (direct-attached copper cable) 5 m passive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-QSFP-DACBO-1M\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eQSFP+ to SFP+ 10 Gigabit Ethernet Direct Attach Breakout Copper (direct-attached copper cable) 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-QSFP-DACBO-3M\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eQSFP+ to SFP+ 10 Gigabit Ethernet Direct Attach Breakout Copper (direct-attached copper cable) 3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-QSFP-40G-SR4\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eQSFP+ 40GBASE-SR4 40 Gigabit Optics, 850 nm for up to 150 m transmission on MMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-QSFP-40G-ESR4\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eQSFP+ 40GBASE-ESR4 40 Gigabit Optics, 300 m (400 m) with OM3 (OM4) MMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eJNP-QSFP-40G-LR4\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eQSFP+ 40GBASE-LR4 40 Gigabit Optics, 1,310 nm for up to 10 km transmission on SMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-1GE-T\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP 1000BASE-T Copper Transceiver Module for up to 100 m transmission on Cat5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-1GE-SX\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP 1000BASE-SX Gigabit Ethernet Optics, 850 nm for up to 550 m transmission on MMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-1GE-LX\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP 1000BASE-LX Gigabit Ethernet Optics, 1,310 nm for 10 km transmission on SMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eEX4600-AFL\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eEX4600 Advanced feature license for IS-IS, BGP, and MPLS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eEX-QFX-MACSEC-AGG\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eMACsec Software License for EX4600 as a campus aggregation switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/accesories] \u003cspan\u003eThe EX4600 line of Ethernet switches delivers data center class scale, high availability, and high performance to campus distribution deployments. The EX4600 gives the flexibility to also be implemented in data center top-of-rack and service provider aggregation deployments.\u003c\/span\u003e","brand":"Juniper","offers":[{"title":"Default Title","offer_id":48013261537497,"sku":"EX4600-40F-AFI-NEW","price":10423.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/ex4600-40_dd946ed6-20af-4800-b922-89908a995f59.jpg?v=1771852873","url":"https:\/\/www.aloinfo.com.co\/pt-br\/products\/juniper-ex4600-40f-afi-switch-t5dpt","provider":"aloinfousa.com","version":"1.0","type":"link"}