{"product_id":"juniper-acx-mic-6ge-cu-sfp-interface-card-zowg9","title":"Juniper ACX-MIC-6GE-CU-SFP Interface Card","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\n\u003cli\u003eInterface Card\u003c\/li\u003e\n\u003cli\u003e6 x GE Combo MIC\u003c\/li\u003e\n\u003cli\u003efor ACX4000\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n\u003cp class=\"p1\"\u003e[properties]\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003ctable border=\"1\" dir=\"ltr\" cellpadding=\"0\" cellspacing=\"0\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"222\"\u003e\n\u003ccol width=\"364\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Properties\"}'\u003eProperties\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Juniper ACX-MIC-6GE-CU-SFP\"}'\u003eJuniper ACX-MIC-6GE-CU-SFP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Description\"}'\u003eDescription\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Interface Card, 6 x GE Combo MIC, for ACX4000\"}'\u003eInterface Card, 6 x GE Combo MIC, for ACX4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Product Family\"}'\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"ACX4000 Series\"}'\u003eACX4000 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Product Type\"}'\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Modular Interface Card\"}'\u003eModular Interface Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Ports\"}'\u003ePorts\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"6 tri-speed (10\/100\/1000 Mbps) ports, either RJ-45 or SFP\"}'\u003e6 tri-speed (10\/100\/1000 Mbps) ports, either RJ-45 or SFP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Weight (lb\/kg)\"}'\u003eWeight (lb\/kg)\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"1.2 lb (0.54 kg)\"}'\u003e1.2 lb (0.54 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Power requirement without PoE\"}'\u003ePower requirement without PoE\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"1.5 A @ 12 V (18 W)\"}'\u003e1.5 A @ 12 V (18 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"p1\"\u003e[\/properties][specifications]\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003ctable border=\"1\" dir=\"ltr\" cellpadding=\"0\" cellspacing=\"0\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"383\"\u003e\n\u003ccol width=\"393\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Specifications\"}'\u003eSpecifications\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"ACX-MIC-6GE-CU-SFP\"}'\u003eACX-MIC-6GE-CU-SFP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"System Throughput\"}'\u003eSystem Throughput\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"up to 1 Gbps\"}'\u003eup to 1 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Operating temperature\"}'\u003eOperating temperature\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"-40° to 149° F (-40° to 65° C)\"}'\u003e-40° to 149° F (-40° to 65° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Humidity\"}'\u003eHumidity\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"95% RH noncondensing\"}'\u003e95% RH noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Safety Approvals\"}'\u003eSafety Approvals\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"CAN\/CSA-C22.2 No. 60950-1\\nUL 60950-1\\nEN 60950-1\\nIEC 60950-1CB Scheme\\nEN 60825-1\"}'\u003eCAN\/CSA-C22.2 No. 60950-1\u003cbr\u003eUL 60950-1\u003cbr\u003eEN 60950-1\u003cbr\u003eIEC 60950-1CB Scheme\u003cbr\u003eEN 60825-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"EMC\"}'\u003eEMC\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"AS\/NZS CISPR22 Class A\\nEN55022 Class A\\nVCCI Class A\\nFCC Part 15 Class A\\nIECS-003 Issue 4\\nBSMI CNS 13438 and NCC C6357 Taiwan Radiated Emissions\\nKN 22, Class A\\nCISPR 32\/EN55032: 2012 European Radiated Emissions Class A\\nEN-61000-4-6 Low Frequency Common Immunity\\nEN-61000-4-11 Voltage Dips and Sags\\nCISPR 24\/EN55024 Information Technology Equipment Immunity Characteristics\"}'\u003eAS\/NZS CISPR22 Class A\u003cbr\u003eEN55022 Class A\u003cbr\u003eVCCI Class A\u003cbr\u003eFCC Part 15 Class A\u003cbr\u003eIECS-003 Issue 4\u003cbr\u003eBSMI CNS 13438 and NCC C6357 Taiwan Radiated Emissions\u003cbr\u003eKN 22, Class A\u003cbr\u003eCISPR 32\/EN55032: 2012 European Radiated Emissions Class A\u003cbr\u003eEN-61000-4-6 Low Frequency Common Immunity\u003cbr\u003eEN-61000-4-11 Voltage Dips and Sags\u003cbr\u003eCISPR 24\/EN55024 Information Technology Equipment Immunity Characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"ETSI (European Telecommunications Standardization Institute)\"}'\u003eETSI (European Telecommunications Standardization Institute)\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"EN 300 386 V1.6.1 Telecommunication Network Equipment, Electromagnetic Compatibility Requirements\\nETSI EN 300 019-2-1 (2000) Storage, Class T1.2\\nETSI EN 300 019-2-2 (1999) Transportation, Class T2.3\\nETSI EN 300 019-2-4 (2003) Stationary Use at Non-Weather Protected Locations, Class 4.1 \\nETSI 300753 (1997) Acoustic Noise Emitted by Telecommunications Equipment \"}'\u003eEN 300 386 V1.6.1 Telecommunication Network Equipment, Electromagnetic Compatibility Requirements\u003cbr\u003eETSI EN 300 019-2-1 (2000) Storage, Class T1.2\u003cbr\u003eETSI EN 300 019-2-2 (1999) Transportation, Class T2.3\u003cbr\u003eETSI EN 300 019-2-4 (2003) Stationary Use at Non-Weather Protected Locations, Class 4.1 \u003cbr\u003eETSI 300753 (1997) Acoustic Noise Emitted by Telecommunications Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"NEBS\"}'\u003eNEBS\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"SR-3580 NEBS Criteria Levels (Level 3 Compliance)\\nGR-63-CORE: NEBS, Physical Protection\\nGR-1089-CORE: EMC and Electrical Safety for Network Telecommunications Equipment (Issue 6 compliant)\\nGR-3108-CORE: Generic Requirements for Network Equipment in the Outside Plant (OSP)\"}'\u003eSR-3580 NEBS Criteria Levels (Level 3 Compliance)\u003cbr\u003eGR-63-CORE: NEBS, Physical Protection\u003cbr\u003eGR-1089-CORE: EMC and Electrical Safety for Network Telecommunications Equipment (Issue 6 compliant)\u003cbr\u003eGR-3108-CORE: Generic Requirements for Network Equipment in the Outside Plant (OSP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Telecomm Compliance\"}'\u003eTelecomm Compliance\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"T1 and XDSL Interfaces FCC Part 68 (T1 Only)\\nIndustry Canada CS-03\\nJATE Green Book\\nE1 Interface TBR 12\/13\\nACA TS016 \\nG.703 \\nRTTE Directive 1995\/5\/EC\\nDevice management: NETCONF, CLI, SNMP v1\/v2\/v3\\nEnd-to-end provisioning of E-Line, emulated LAN (ELAN), Layer 3 VPN (L3VPN), OAM, class of service (CoS)\\nDevice and service-level fault management\\nDevice and service-level performance management\"}'\u003eT1 and XDSL Interfaces FCC Part 68 (T1 Only)\u003cbr\u003eIndustry Canada CS-03\u003cbr\u003eJATE Green Book\u003cbr\u003eE1 Interface TBR 12\/13\u003cbr\u003eACA TS016 \u003cbr\u003eG.703 \u003cbr\u003eRTTE Directive 1995\/5\/EC\u003cbr\u003eDevice management: NETCONF, CLI, SNMP v1\/v2\/v3\u003cbr\u003eEnd-to-end provisioning of E-Line, emulated LAN (ELAN), Layer 3 VPN (L3VPN), OAM, class of service (CoS)\u003cbr\u003eDevice and service-level fault management\u003cbr\u003eDevice and service-level performance management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Metro Ethernet Forum (MEF)\"}'\u003eMetro Ethernet Forum (MEF)\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"MEF CE2.0 compliant\"}'\u003eMEF CE2.0 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"p1\"\u003e[\/specifications][accesories] [\/accesories]\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eJuniper ACX4000 Universal Metro Router is a 2.5 U, actively cooled access router that is environmentally hardened for field deployment. This versatile, high-performance mobile access platform runs on the Junos operating system.\u003c\/span\u003e\u003c\/p\u003e","brand":"Juniper","offers":[{"title":"Default Title","offer_id":48013239386329,"sku":"ACX-MIC-6GE-CU-SFP-NEW","price":2038.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/ACX-MIC-6GE-CU-SFP_3a4bab4b-a383-4799-b9f8-a725f326c575.jpg?v=1771852484","url":"https:\/\/www.aloinfo.com.co\/pt-br\/products\/juniper-acx-mic-6ge-cu-sfp-interface-card-zowg9","provider":"aloinfousa.com","version":"1.0","type":"link"}