{"product_id":"cisco-ucs-c240-m6-sff-rack-server-cto","title":"Cisco UCS C240 M6 SFF Rack Server CTO","description":"\u003cdiv class=\"product-section container is-gap-10 is-flex-row\"\u003e\n    \u003cdiv class=\"twelve columns medium-down--one-whole-NG product-section-extras quick-specs row-col\"\u003e\n        \u003cdiv class=\"one-whole medium-down--one-whole-NG quick-specs-data\"\u003e\n            \u003cdiv class=\"hfour\"\u003eWhat's New\u003c\/div\u003e\n            \u003cdiv class=\"other-version-medium-down-scroll\"\u003e\n\u003cul class=\"margin-empty margin-bottom\"\u003e\n\u003cli\u003e(2) Intel Xeon 3rd Gen Scalable Processors\u003c\/li\u003e\n\u003cli\u003e(32) 3200MT\/s DDR4 DIMMs\u003c\/li\u003e\n\u003cli\u003eSupport for Intel® Optane™ Persistent Memory (PMem)\u003c\/li\u003e\n\u003cli\u003e(24) SFF SAS\/SATA\/NVMe only\u003c\/li\u003e\n\u003cli\u003e(2) Rear Drives SAS\/SATA\/NVMe\u003c\/li\u003e\n\u003cli\u003e(8) PCIe 4.0 Slots\u003c\/li\u003e\n\u003cli\u003e(5) GPU Support\u003c\/li\u003e\n\u003cli\u003eDedicated mLOM Slot\u003c\/li\u003e\n\u003cli\u003eDedicated Cisco 12G SAS Modular RAID controller Slot\u003c\/li\u003e\n\u003cli\u003eEmbedded 2 x 10GBASE-T LAN-on-motherboard (LOM)\u003c\/li\u003e\n\u003cli\u003e(6) Hot Swap Fans\u003c\/li\u003e\n\u003cli\u003ePCIe NVMe drives are controlled directly from the CPUs\u003c\/li\u003e\n\u003cli\u003eThere is no RAID support for NVMe drives.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003chr class=\"is-hidden-mobile-only\"\u003e     \n        \u003cdiv class=\"other-versions medium-down--one-third-NG\"\u003e\n            \u003cb\u003eOther Versions\u003c\/b\u003e\n\u003cul class=\"margin-empty margin-bottom\"\u003e\n\u003cli\u003e\n\u003ca alt=\"Cisco C220 M4 Configure To Order Rack Server\" title=\"Cisco C220 M4 Configure To Order Rack Server\" href=\"\/pt-br\/collections\/cisco-c-series-cto\/cisco-series-c220-m4+cisco-m4\"\u003eCisco C220 M4\u003c\/a\u003e | \u003ca alt=\"Cisco C220 M5 Configure To Order Rack Server\" title=\"Cisco C220 M5 Configure To Order Rack Server\" href=\"\/pt-br\/collections\/cisco-c-series-cto\/cisco-series-c220-m4+cisco-m5\"\u003eM5\u003c\/a\u003e | \u003ca alt=\"Cisco C220 M6 Configure To Order Rack Server\" title=\"Cisco C220 M6 Configure To Order Rack Server\" href=\"\/pt-br\/collections\/cisco-c-series-cto\/products\/cisco-c220-m6-rack-server\"\u003eM6\u003c\/a\u003e | \u003ca alt=\"Cisco C220 M7 Configure To Order Rack Server\" title=\"Cisco C220 M7 Configure To Order Rack Server\" href=\"\/pt-br\/collections\/cisco-c-series-cto\/products\/cisco-ucs-c220-m7-10x-2-5-cto\"\u003eM7\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca alt=\"Cisco C240 M4 Configure To Order Rack Server\" title=\"Cisco C240 M4 Configure To Order Rack Server\" href=\"\/pt-br\/collections\/cisco-c-series-cto\/cisco-series-c240-m4+cisco-m4\"\u003eCisco C240 M4\u003c\/a\u003e | \u003ca alt=\"Cisco C240 M5 Configure To Order Rack Server\" title=\"Cisco C240 M5 Configure To Order Rack Server\" href=\"\/pt-br\/collections\/cisco-c-series-cto\/cisco-series-c240-m4+cisco-m5\"\u003eM5\u003c\/a\u003e | \u003ca alt=\"Cisco C240 M6 Configure To Order Rack Server\" title=\"Cisco C240 M6 Configure To Order Rack Server\" href=\"\/pt-br\/collections\/cisco-c-series-cto\/cisco-series-c240-m4+cisco-m6\"\u003eM6\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e(Click to View)\u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"four-NG-plus medium-down--one-whole-NG product-section-extras ideal-for\"\u003e\n        \u003cdiv class=\"hfour\"\u003eIdeal for:\u003c\/div\u003e\n\u003cul class=\"margin-empty margin-bottom\"\u003e\n\u003cli title=\"Click to view Artificial intelligence (AI) Servers\" data-page=\"workload-ai\" class=\"click-cell\"\u003eArtificial Intelligence (AI)\u003c\/li\u003e\n\u003cli title=\"Click to view Big Data Servers\" data-page=\"workload-big-data\" class=\"click-cell\"\u003eBig Data Analytics\u003c\/li\u003e\n\u003cli title=\"Click to view Cloud Servers\" data-page=\"workload-cloud\" class=\"click-cell\"\u003eCloud Servers\u003c\/li\u003e\n\u003cli title=\"Click to view Data Analytic Servers\" data-page=\"workload-data-analytics\" class=\"click-cell\"\u003eData Analytics\u003c\/li\u003e\n\u003cli title=\"Click to view Database Servers\" data-page=\"workload-database\" class=\"click-cell\"\u003eDatabase\u003c\/li\u003e\n\u003cli title=\"Click to view Deep Learning\" data-page=\"workload-dl\" class=\"click-cell\"\u003eDeep Learning (DL)\u003c\/li\u003e\n\u003cli title=\"Click to view High-Performance Computing (HPC) Servers\" data-page=\"workload-hpc\" class=\"click-cell\"\u003eHigh-Performance Computing (HPC)\u003c\/li\u003e\n\u003cli title=\"Click to view Machine Learning (ML) Servers\" data-page=\"workload-ml\" class=\"click-cell\"\u003eMachine Learning (ML)\u003c\/li\u003e\n\u003cli title=\"Click to view Virtualization Servers\" data-page=\"workload-virtualization\" class=\"click-cell\"\u003eVirtualization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cp\u003eThe Cisco UCS C240 M6 Rack Server is a 2-socket, 2-Rack-Unit (2RU) rack server offering industry-leading performance and expandability. It supports a wide range of storage and I\/O-intensive infrastructure workloads, from big data and analytics to collaboration. Cisco UCS C-Series M6 Rack Servers can be deployed as standalone servers or as part of a Cisco Unified Computing System (Cisco UCS) managed environment, and now with Cisco Intersight is able to take advantage of Cisco’s standards-based unified computing innovations that help reduce customers’ Total Cost of Ownership (TCO) and increase their business agility.\u003c\/p\u003e\n\u003cp\u003eThe server accommodates up to 12 front facing SAS-only LFF drives, up to 4 mid-plane SAS-only LFF drives, and up to 4 rear-facing SFF drives (SAS or SATA or NVMe).\u003c\/p\u003e\n\u003cp\u003eIf a Midplane is installed GPUs are not supported.\u003c\/p\u003e\n\n\u003cdiv class=\"description-title-divider shadow margin-bottom\"\u003eChassis Options\u003c\/div\u003e\n\u003cdiv class=\"product-section container jc-between-center is-flex-row product-section-extras \"\u003e\n\u003cdiv class=\"eight medium-down--one-whole-NG image-center image_by_text\"\u003e\u003cimg title=\"UCS C240 C-Series M6 12x 3.5 LFF UCSC-C240-M6L\" alt=\"UCS C240 C-Series M6 12x 3.5 LFF UCSC-C240-M6L\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-c240-12-lff-description.png\" srcset=\"\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-c240-12-lff-description_400x.png 400w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-c240-12-lff-description_600x.png 600w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-c240-12-lff-description_800x.png 800w,\n    \" sizes=\"(min-width: 900px) 394px, (min-width: 408px) 100vw\" loading=\"lazy\" width=\"394\" height=\"219\" style=\"width: 100%; height: auto; display: block;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"eight medium-down--one-whole-NG padding-full specs specs-fit\"\u003e\n\u003cb\u003eUCS C240 C-Series M6 12 LFF\u003cbr\u003eUCSC-C240-M6L\u003c\/b\u003e\n\u003cp\u003e(12) LFF SAS\/SATA Drives\u003c\/p\u003e\n\u003cp\u003e(4) Midplane LFF SAS Drives\u003c\/p\u003e\n\u003cp\u003eUp to (4) Rear SFF SAS\/SATA\/NVMe Drives\u003c\/p\u003e\n\u003cp\u003eMid Drives \u0026amp; GPUs cant be installed together\u003c\/p\u003e\n\u003cp\u003eRisers Option\u003c\/p\u003e\n\u003cp class=\"last\"\u003e1B, 2A, 3B\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp title=\"View C240 M5 LFF CTO\" alt=\"View C240 M5 LFF CTO\" data-page=\"collections\/cisco-c-series-cto\/products\/cisco-c240-m6-cto-rack-server\" class=\"text-center last click-cell\"\u003eView C240 M6 LFF CTO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv class=\"product-section container jc-between-center is-flex-row\"\u003e\n\u003cdiv class=\"eight medium-down--one-whole-NG margin-bottom\"\u003e\n\u003cb\u003eDrive Rules and Limitations\u003c\/b\u003e\n\u003cul class=\"margin-empty\"\u003e\n\u003cli\u003eYou can mix HDDs and SSDs as long as you keep all HDDs in their own RAID volume and all SSDs in their own RAID volume.\u003c\/li\u003e\n\u003cli\u003eYou can mix SAS HDDs and SAS\/SATA SSDs when using the Cisco 12G SAS RAID controller or Cisco 12G SAS HBA.\u003c\/li\u003e\n\u003cli\u003eIf you order any SFF NVMe rear drives, you must also order two CPUs.\u003c\/li\u003e\n\u003cli\u003eSED drives can be mixed with non-SED drives in Table 11 on page 27\u003c\/li\u003e\n\u003cli\u003e2.5-inch SFF NVMe drives are connected directly to the CPU, and are not managed by the RAID controller or SAS HBA.\u003c\/li\u003e\n\u003cli\u003eYou cannot mix SAS\/SATA with NVMe rear drives. They must be all SAS\/SATA or all NVMe\u003c\/li\u003e\n\u003cli\u003eA midplane kit (PID UCSC-MPSTOM6L-KIT) is required\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIf a Midplane is installed GPUs are not supported.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eight medium-down--one-whole-NG margin-bottom\"\u003e\n\u003cb\u003eVROC Requirments\u003c\/b\u003e\n\u003cul class=\"margin-empty\"\u003e\n\u003cli\u003eIntel® VROC is only supported with Intel drives\u003c\/li\u003e\n\u003cli\u003eIntel® VROC enablement key factory pre-provisioned to BIOS - no additional licensing required.\u003c\/li\u003e\n\u003cli\u003eSmall Form Factor (SFF) drive support (only)\u003c\/li\u003e\n\u003cli\u003eNo battery backup (BBU) or external SuperCap needed\u003c\/li\u003e\n\u003cli\u003eSoftware-based solution utilizing Intel SFF NVMe direct connected to Intel CPU\u003c\/li\u003e\n\u003cli\u003eRAID 0\/1\/5\/10 support\u003c\/li\u003e\n\u003cli\u003eWindows, Linux, VMware OS support.\u003c\/li\u003e\n\u003cli\u003eHost Tools- Windows GUI\/CLI, Linux CLI.\u003c\/li\u003e\n\u003cli\u003eUEFI Support- HII Utility, OBSE.\u003c\/li\u003e\n\u003cli\u003eIntel VROC NVMe operates in UEFI mode only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n  \n  \n\u003chr\u003e\n\u003cdiv class=\"product-section container jc-between-center is-flex-row\"\u003e\n\u003cdiv class=\"one-fourth medium-down--one-whole-NG product-section-extras specs\"\u003e\n\u003cdiv class=\"click-cell view-server\" title=\"Cisco C240 M6 SFF 12 Drive | UCSC-C240-M6S\" alt=\"Cisco C240 M6 SFF 12 Drive | UCSC-C240-M6S\" data-page=\"cisco-c240-m6-sff-12-drive-ucsc-c240-m6s\"\u003e\n    \u003cimg alt=\"Cisco C240 M6 SFF 12 Drive | UCSC-C240-M6S\" title=\"Cisco C240 M6 SFF 12 Drive | UCSC-C240-M6S\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-c240-UCSC-C240-M6S-description_300x.png\" srcset=\"\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-c240-UCSC-C240-M6S-description_300x.png 300w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-c240-UCSC-C240-M6S-description_600x.png 600w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-c240-UCSC-C240-M6S-description_800x.png 800w,\n    \" sizes=\"(min-width: 900px) 206px, (min-width: 408px) 100vw\" loading=\"lazy\" width=\"206\" height=\"115\" style=\"width: 100%; height: auto; display: block;\"\u003e UCS C240 M6 12 SFF \u003cbr\u003eUCSC-C240-M6S\u003c\/div\u003e\n\u003cdiv class=\"padding-full\"\u003e\n\u003cp\u003e(12) SAS\/SATA Drives\u003c\/p\u003e\n\u003cp\u003e(1-4) SAS\/SATA\/NVMe\u003c\/p\u003e\n\u003cp\u003e(5-12) SAS\/SATA\u003c\/p\u003e\n\u003cp\u003e(2) Rear SFF SAS\/SATA\/NVMe\u003c\/p\u003e\n\u003cp\u003eSATA Interposer installed, supports up to 8 SATA-only\u003c\/p\u003e\n\u003cp\u003eOptional media drive\u003c\/p\u003e\n\u003cp class=\"last bold\"\u003eI\/O Centric Risers\u003c\/p\u003e\n\u003cp\u003e1A, 2A, 3A, 3C\u003c\/p\u003e\n\u003cp class=\"last bold\"\u003eStorage Centric Risers\u003c\/p\u003e\n\u003cp\u003e1A, 2A, 3B, 3C\u003c\/p\u003e\n\u003cp title=\"Cisco C240 M6 SFF CTO\" alt=\"Cisco C240 M6 SFF CTO\" data-page=\"\/collections\/cisco-c-series-cto\/products\/cisco-c240-m6-sff-cto-rack-server\" class=\"text-center last click-cell\"\u003eView C240 M6 SFF CTO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"one-fourth medium-down--one-whole-NG product-section-extras specs\"\u003e\n\u003cdiv class=\"click-cell view-server\" title=\"Cisco C240 M6 SFF 24 Drive | UCSC-C240-M6SX\" alt=\"Cisco C240 M6 SFF 24 Drive | UCSC-C240-M6SX\" data-page=\"cisco-c240-m6-sff-24-drive-ucsc-c240-m6sx\"\u003e\n    \u003cimg alt=\"Cisco C240 M6 SFF 24 Drive | UCSC-C240-M6SX\" title=\"Cisco C240 M6 SFF 24 Drive | UCSC-C240-M6SX\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-c240-24drives-description_300x.png\" srcset=\"\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-c240-24drives-description_300x.png 300w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-c240-24drives-description_600x.png 600w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-c240-24drives-description_800x.png 800w,\n    \" sizes=\"(min-width: 900px) 206px, (min-width: 408px) 100vw\" loading=\"lazy\" width=\"206\" height=\"115\" style=\"width: 100%; height: auto; display: block;\"\u003e UCS C240 M6 24 SFF \u003cbr\u003eUCSC-C240-M6SX\u003c\/div\u003e\n\u003cdiv class=\"padding-full\"\u003e\n\u003cp\u003e(24) SAS\/SATA\/NVMe Drives\u003c\/p\u003e\n\u003cp\u003eDrives (1-4) support SAS\/SATA\/NVMe\u003c\/p\u003e\n\u003cp\u003eDrives (5-24) support SAS\/SATA\u003c\/p\u003e\n\u003cp\u003eUp to (2 or 4) Rear SFF SAS\/SATA\/NVMe Drives\u003c\/p\u003e\n\u003cp class=\"last bold\"\u003eI\/O Centric Risers\u003c\/p\u003e\n\u003cp\u003e1A, 2A, 3A, 3C\u003c\/p\u003e\n\u003cp class=\"last bold\"\u003eStorage Centric Risers\u003c\/p\u003e\n\u003cp\u003e1B, 3B, 3C\u003c\/p\u003e\n\u003cp title=\"Cisco C240 M6 SFF CTO\" alt=\"Cisco C240 M6 SFF CTO\" data-page=\"\/collections\/cisco-c-series-cto\/products\/cisco-c240-m6-sff-cto-rack-server\" class=\"text-center last click-cell\"\u003eView C240 M6 SFF CTO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"one-fourth medium-down--one-whole-NG product-section-extras specs\"\u003e\n\u003cdiv class=\"click-cell view-server\" title=\"Cisco C240 M6 SFF 12 NVMe Drive | UCSC-C240-M6N\" alt=\"Cisco C240 M6 SFF 12 NVMe Drive | UCSC-C240-M6N\" data-page=\"cisco-c240-m6-sff-12-nvme-drive-ucsc-c240-m6n\"\u003e\n    \u003cimg alt=\"Cisco C240 M6 SFF 12 NVMe Drive | UCSC-C240-M6N\" title=\"Cisco C240 M6 SFF 12 NVMe Drive | UCSC-C240-M6N\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-c240-12-nvme-description_300x.png\" srcset=\"\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-c240-12-nvme-description_300x.png 300w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-c240-12-nvme-description_600x.png 600w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-c240-12-nvme-description_800x.png 800w,\n    \" sizes=\"(min-width: 900px) 206px, (min-width: 408px) 100vw\" loading=\"lazy\" width=\"206\" height=\"115\" style=\"width: 100%; height: auto; display: block;\"\u003e UCS C240 M6 12 NVMe Drive \u003cbr\u003eUCSC-C240-M6N\u003c\/div\u003e\n\u003cdiv class=\"padding-full\"\u003e\n\u003cp\u003e(12) NVMe Drives\u003c\/p\u003e\n\u003cp\u003eUp to (2) Rear NVMe Only\u003c\/p\u003e\n\u003cp\u003eOptional media drive\u003c\/p\u003e\n\u003cp class=\"last bold\"\u003eI\/O Centric Risers\u003c\/p\u003e\n\u003cp\u003e1A, 2A\u003c\/p\u003e\n\u003cp class=\"last bold\"\u003eStorage Centric Risers\u003c\/p\u003e\n\u003cp\u003e1B\u003c\/p\u003e\n\u003cp title=\"Cisco C240 M6 SFF CTO\" alt=\"Cisco C240 M6 SFF CTO\" data-page=\"\/collections\/cisco-c-series-cto\/products\/cisco-c240-m6-sff-cto-rack-server\" class=\"text-center last click-cell\"\u003eView C240 M6 SFF CTO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"one-fourth medium-down--one-whole-NG product-section-extras specs\"\u003e\n\u003cdiv class=\"click-cell view-server\" title=\"Cisco C240 M6 SFF 24 NVMe Drive | UCSC-C240-M6SN\" alt=\"Cisco C240 M6 SFF 24 NVMe Drive | UCSC-C240-M6SN\" data-page=\"cisco-c240-m6-sff-24-nvme-drive-ucsc-c240-m6sn\"\u003e\n    \u003cimg alt=\"Cisco C240 M6 SFF 24 NVMe Drive | UCSC-C240-M6SN\" title=\"Cisco C240 M6 SFF 24 NVMe Drive | UCSC-C240-M6SN\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-c240-24drives-description_300x.png\" srcset=\"\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-c240-24drives-description_300x.png 300w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-c240-24drives-description_600x.png 600w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-c240-24drives-description_800x.png 800w,\n    \" sizes=\"(min-width: 900px) 206px, (min-width: 408px) 100vw\" loading=\"lazy\" width=\"206\" height=\"115\" style=\"width: 100%; height: auto; display: block;\"\u003e UCS C240 M6 24 NVMe \u003cbr\u003eUCSC-C240-M6SN\u003c\/div\u003e\n\u003cdiv class=\"padding-full\"\u003e\n\u003cp\u003e(24) NVMe Drives\u003c\/p\u003e\n\u003cp\u003eUp to (2) Rear NVMe Only\u003c\/p\u003e\n\u003cp class=\"last bold\"\u003eI\/O Centric Risers\u003c\/p\u003e\n\u003cp\u003e1A, 2A\u003c\/p\u003e\n\u003cp class=\"last bold\"\u003eStorage Centric Risers\u003c\/p\u003e\n\u003cp\u003e1B\u003c\/p\u003e\n\u003cp title=\"Cisco C240 M6 SFF CTO\" alt=\"Cisco C240 M6 SFF CTO\" data-page=\"\/collections\/cisco-c-series-cto\/products\/cisco-c240-m6-sff-cto-rack-server\" class=\"text-center last click-cell\"\u003eView C240 M6 SFF CTO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Title --\u003e\n\u003cdiv class=\"description-title-divider shadow margin-bottom\"\u003eMemory Options\u003c\/div\u003e\n\u003cdiv class=\"product-section container jc-between-center is-flex-row\"\u003e\n\u003cdiv class=\"one-thirds medium-down--one-whole-NG\"\u003e\n\u003cp\u003e32 DDR4 DIMM slots: 16, 32, 64, 128 and 256 GB up to 3200 MHz Support for the Intel Optane DC persistent memory (128G, 256G, 512G). DIMM mixing is not allowed when PMem are installed; in these cases, all DIMMs must be the same type and size.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"one-thirds medium-down--one-whole-NG\"\u003e\n\u003cb\u003eSupported Memory\u003c\/b\u003e\n\u003cul class=\"margin-empty\"\u003e\n\u003cli\u003eClock speed: 3200 MHz\u003c\/li\u003e\n\u003cli\u003eRanks per DIMM: 1, 2, 4, or 8\u003c\/li\u003e\n\u003cli\u003eOperational voltage: 1.2 V\u003c\/li\u003e\n\u003cli\u003eRegistered ECC DDR4 DIMMS (RDIMMs), Load-reduced DIMMs (LRDIMMs), or Intel® Optane™ Persistent Memory Modules (PMem).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"one-thirds medium-down--one-whole-NG\"\u003e\n\u003cb\u003eMax Memory:\u003c\/b\u003e\n\u003cul class=\"margin-empty\"\u003e\n\u003cli\u003e4 TB: 32 x 128 GB DDR4 DIMMs\u003c\/li\u003e\n\u003cli\u003e10 TB: 16 x 128 GB DDR4 DIMMs and 16 x 512 GB Intel® Optane™ Persistent Memory Modules (PMem).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n  \n\u003c!-- Title --\u003e\n\u003cdiv class=\"description-title-divider shadow margin-bottom\"\u003ePCIe Expansion Options\u003c\/div\u003e\n  \u003cdiv class=\"product-section container jc-between-center is-flex-row\"\u003e\n\u003cdiv class=\"eight medium-down--one-whole-NG\"\u003e\n\u003cp\u003e8 PCIe 4.0 slots, 1 dedicated 12-Gbps RAID controller slot and 1 dedicated mLOM slot. With 8PCIe slots the system is able to support up to 5 A10 Single Wide GPUs. Slots 4, 5, and 6 on riser card 2A accommodate single-wide GPUs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eight medium-down--one-whole-NG\"\u003e\n\u003cp\u003eRiser 2 and 3 connect to CPU 2 and if they are not installed then you will need to add the Riser Filler Blanks for optimal air flow.\u003c\/p\u003e\n\u003cul class=\"margin-empty margin-bottom\"\u003e\n\u003cli\u003eRiser 2 Blank UCSC-FBRS2-C240M6\u003c\/li\u003e\n\u003cli\u003eRiser 3 Blank UCSC-FBRS3-C240M6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \n\u003chr\u003e\n\u003cp class=\"text-center\"\u003eNot all risers are available in every server configuration option\u003c\/p\u003e\n\u003chr\u003e\n\u003cdiv class=\"product-section container jc-between-center is-flex-row\"\u003e\n\u003cdiv class=\"one-third medium-down--one-whole-NG product-section-extras specs\"\u003e\n\u003cdiv class=\"click-cell view-server\" title=\"Cisco UCS C240 C-Series M6 Riser 1A\" alt=\"Cisco UCS C240 C-Series M6 Riser 1A\" data-page=\"cisco-c240-m6-pcie-riser-1a-ucsc-ris1a-240m6\"\u003e\n    \u003cimg alt=\"Cisco UCS C240 C-Series M6 Riser 1A\" title=\"Cisco UCS C240 C-Series M6 Riser 1A\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser1A-description_300x.png\" srcset=\"\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser1A-description_300x.png 300w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser1A-description_600x.png 600w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser1A-description_800x.png 800w,\n    \" sizes=\"(min-width: 900px) 282px, (min-width: 408px) 100vw\" loading=\"lazy\" width=\"282\" height=\"158\" style=\"width: 100%; height: auto; display: block;\"\u003e Riser 1A\u003c\/div\u003e\n\u003cdiv class=\"padding-full\"\u003e\n\u003cp\u003eSlot 1 is full-height, 3\/4 length, x8, NCSI\u003c\/p\u003e\n\u003cp\u003eSlot 2 is full-height, full-length, x16, NCSI\u003c\/p\u003e\n\u003cp\u003eSlot 3 is full-height, full-length, x8, no NCSI\u003c\/p\u003e\n\u003cp class=\"last\"\u003eI\/O-centric\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"one-third medium-down--one-whole-NG product-section-extras specs\"\u003e\n\u003cdiv class=\"click-cell view-server\" title=\"Cisco UCS C240 C-Series M6 Riser 1B\" alt=\"Cisco UCS C240 C-Series M6 Riser 1B\" data-page=\"cisco-c240-m6-pcie-riser-1b-ucsc-ris1b-240m6\"\u003e\n    \u003cimg alt=\"Cisco UCS C240 C-Series M6 Riser 1B\" title=\"Cisco UCS C240 C-Series M6 Riser 1B\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser1B-description_300x.png\" srcset=\"\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser1B-description_300x.png 300w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser1B-description_600x.png 600w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser1B-description_800x.png 800w,\n    \" sizes=\"(min-width: 900px) 282px, (min-width: 408px) 100vw\" loading=\"lazy\" width=\"282\" height=\"158\" style=\"width: 100%; height: auto; display: block;\"\u003e Riser 1B\u003c\/div\u003e\n\u003cdiv class=\"padding-full\"\u003e\n\u003cp\u003eSlot 1 is reserved\u003c\/p\u003e\n\u003cp\u003eSlot 2 (drive bay 102), x4\u003c\/p\u003e\n\u003cp\u003eSlot 3 (drive bay 101), x4\u003c\/p\u003e\n\u003cp\u003eSupports SAS\/SATA\/NVMe\u003c\/p\u003e\n\u003cp class=\"last\"\u003eStorage-centric\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"one-third medium-down--one-whole-NG product-section-extras specs\"\u003e\n\u003cdiv class=\"click-cell view-server\" title=\"Cisco UCS C240 C-Series M6 Riser 2A\" alt=\"Cisco UCS C240 C-Series M6 Riser 2A\" data-page=\"cisco-c240-m6-pcie-riser-2a-ucsc-ris2a-240m6\"\u003e\n    \u003cimg alt=\"Cisco UCS C240 C-Series M6 Riser 2A\" title=\"Cisco UCS C240 C-Series M6 Riser 2A\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser2A-description_300x.png\" srcset=\"\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser2A-description_300x.png 300w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser2A-description_600x.png 600w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser2A-description_800x.png 800w,\n    \" sizes=\"(min-width: 900px) 282px, (min-width: 408px) 100vw\" loading=\"lazy\" width=\"282\" height=\"158\" style=\"width: 100%; height: auto; display: block;\"\u003e Riser 2A\u003c\/div\u003e\n\u003cdiv class=\"padding-full\"\u003e\n\u003cp\u003eSlot 4 is full-height, 3\/4 length, x8\u003c\/p\u003e\n\u003cp\u003eSlot 5 is full-height, full-length, x16\u003c\/p\u003e\n\u003cp\u003eSlot 6 is full-height, full-length, x8\u003c\/p\u003e\n\u003cp class=\"last\"\u003eI\/O-centric\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-section container jc-between-center is-flex-row\"\u003e\n\u003cdiv class=\"one-third medium-down--one-whole-NG product-section-extras specs\"\u003e\n\u003cdiv class=\"click-cell view-server\" title=\"Cisco UCS C240 C-Series M6 Riser 3A\" alt=\"Cisco UCS C240 C-Series M6 Riser 3A\" data-page=\"cisco-c240-m6-pcie-riser-3a-ucsc-ris3a-240m6\"\u003e\n    \u003cimg alt=\"Cisco UCS C240 C-Series M6 Riser 3A\" title=\"Cisco UCS C240 C-Series M6 Riser 3A\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser3A-description_300x.png\" srcset=\"\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser3A-description_300x.png 300w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser3A-description_600x.png 600w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser3A-description_800x.png 800w,\n    \" sizes=\"(min-width: 900px) 282px, (min-width: 408px) 100vw\" loading=\"lazy\" width=\"282\" height=\"158\" style=\"width: 100%; height: auto; display: block;\"\u003e Riser 3A\u003c\/div\u003e\n\u003cdiv class=\"padding-full\"\u003e\n\u003cp\u003eSlot 7 is full-height, full-length, x8\u003c\/p\u003e\n\u003cp\u003eSlot 8 is full-height, full-length, x8\u003c\/p\u003e\n\u003cp class=\"last\"\u003eI\/O-centric\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"one-third medium-down--one-whole-NG product-section-extras specs\"\u003e\n\u003cdiv class=\"click-cell view-server\" title=\"Cisco UCS C240 C-Series M6 Riser 3B\" alt=\"Cisco UCS C240 C-Series M6 Riser 3B\" data-page=\"cisco-c240-m6-pcie-riser-3b-ucsc-ris3b-240m6\"\u003e\n    \u003cimg alt=\"Cisco UCS C240 C-Series M6 Riser 3B\" title=\"Cisco UCS C240 C-Series M6 Riser 3B\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser3B-description_300x.png\" srcset=\"\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser3B-description_300x.png 300w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser3B-description_600x.png 600w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser3B-description_800x.png 800w,\n    \" sizes=\"(min-width: 900px) 282px, (min-width: 408px) 100vw\" loading=\"lazy\" width=\"282\" height=\"158\" style=\"width: 100%; height: auto; display: block;\"\u003e Riser 3B\u003c\/div\u003e\n\u003cdiv class=\"padding-full\"\u003e\n\u003cp\u003eSlot 7 (drive bay 104), x4\u003c\/p\u003e\n\u003cp\u003eSlot 8 (drive bay 103), x4\u003c\/p\u003e\n\u003cp\u003eSupports SAS\/SATA\/NVMe\u003c\/p\u003e\n\u003cp class=\"last\"\u003eStorage-centric\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"one-third medium-down--one-whole-NG product-section-extras specs\"\u003e\n\u003cdiv class=\"click-cell view-server\" title=\"Cisco UCS C240 C-Series M6 Riser 3C\" alt=\"Cisco UCS C240 C-Series M6 Riser 3C\" data-page=\"cisco-c240-m6-pcie-riser-3c-ucsc-ris3c-240m6\"\u003e\n    \u003cimg alt=\"Cisco UCS C240 C-Series M6 Riser 3C\" title=\"Cisco UCS C240 C-Series M6 Riser 3C\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser3C-description_300x.png\" srcset=\"\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser3C-description_300x.png 300w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser3C-description_600x.png 600w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/cisco-ucs-m6-riser3C-description_800x.png 800w,\n    \" sizes=\"(min-width: 900px) 282px, (min-width: 408px) 100vw\" loading=\"lazy\" width=\"282\" height=\"158\" style=\"width: 100%; height: auto; display: block;\"\u003e Riser 3C\u003c\/div\u003e\n\u003cdiv class=\"padding-full\"\u003e\n\u003cp\u003eSlot 7 supports one FH, FL, DW GPU, x16\u003c\/p\u003e\n\u003cp\u003eSlot 8 blocked w\/ a DW GPU is installed\u003c\/p\u003e\n\u003cp class=\"last\"\u003eGPU Support\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cb\u003eGPU\u003c\/b\u003e\n\u003cp\u003e256 GB DIMMs cannot be combined with GPU cards. When a GPU is ordered, the server comes with low-profile heatsinks PID (UCSC-HSLP-M6=) and needs to select a special air duct PID (UCSC-ADGPU-240M6=) for GPUs.\u003c\/p\u003e\n\u003c!-- Title --\u003e\n\u003cdiv class=\"description-title-divider shadow margin-bottom\"\u003ePower \u0026amp; Fan Units\u003c\/div\u003e\n\u003cdiv class=\"product-default-container\"\u003e\n\u003cp\u003eThe chassis is equipped with six fans and two power supplies. In a server with two power supplies, both power supplies must be identical. Hot-pluggable, redundant 1050W AC, 1050W DC, 1600W AC, and 2300W AC\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Title --\u003e\n\u003cdiv class=\"description-title-divider shadow margin-bottom\"\u003eDimensions \u0026amp; Weight\u003c\/div\u003e\n  \u003cdiv class=\"product-section container jc-between-center is-flex-row\"\u003e\n\u003cdiv class=\"eight medium-down--one-whole-NG\"\u003e\n\u003cb\u003eHeight\u003c\/b\u003e\n\u003cp\u003e3.42 in. (8.7 cm)\u003c\/p\u003e\n\u003cb\u003eWidth\u003c\/b\u003e\n\u003cp\u003e(Not including slam latches) 16.9 in.(42.9 cm)\u003c\/p\u003e\n\u003cb\u003eWidth\u003c\/b\u003e\n\u003cp\u003e(including slam latches) 18.9 in.(48.0 cm)\u003c\/p\u003e\n\u003cb\u003eDepth\u003c\/b\u003e\n\u003cp\u003e30 in. (76.2 cm)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eight medium-down--one-whole-NG\"\u003e\n\u003cb\u003eWeight\u003c\/b\u003e\n\u003cp\u003ewith the following options and no rail kit:\u003c\/p\u003e\n\u003cul class=\"margin-empty\"\u003e\n\u003cli\u003e0 HDD, 0 CPU, 0 DIMM, and 1 2400 W power supply 39.13 lbs (17.8 kg)\u003c\/li\u003e\n\u003cli\u003e0 HDD, 0 CPU, 0 DIMM, and 1 2400 W power supply 47.44 lbs (21.5 kg)\u003c\/li\u003e\n\u003cli\u003e1 HDD, 1 CPU, 1 DIMM, and 1 2400 W power supply 41.95 lbs (19 kg)\u003c\/li\u003e\n\u003cli\u003e1 HDD, 1 CPU, 1 DIMM, and 1 2400 W power supply 50.26 lbs (22.8 kg)\u003c\/li\u003e\n\u003cli\u003e12 HDDs, 2 CPUs, 32 DIMMs, and 2 2400 W power supplies 61.7 lbs (28 kg)\u003c\/li\u003e\n\u003cli\u003e12 HDDs, 2 CPUs, 32 DIMMs, and 2 2400 W power supplies 66.75 lbs (30.3 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cisco","offers":[{"title":"Default Title","offer_id":48888341954777,"sku":"UCSB-C240-M6-SFF-CTO","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/cisco-c240-m6-sff-main.jpg?v=1783212545","url":"https:\/\/www.aloinfo.com.co\/pt-br\/products\/cisco-ucs-c240-m6-sff-rack-server-cto","provider":"aloinfousa.com","version":"1.0","type":"link"}