{"product_id":"cisco-pwr-rgd-ac-dc-power-supply-hqfpj","title":"Cisco PWR-RGD-AC-DC Power Supply","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\u003cli\u003ePower supply\u003c\/li\u003e\n\u003cli\u003ehot-plug \/ redundant (plug-in module)\u003c\/li\u003e\n\u003cli\u003eAC 100-240\/ DC 100-250 V\u003c\/li\u003e\n\u003cli\u003e150 Watt\u003c\/li\u003e\n\u003cli\u003efor Cisco 2010\u003c\/li\u003e\n\u003cli\u003e2520; Industrial Ethernet 3010\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable width=\"502\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eProperties\u003c\/td\u003e\n\u003ctd width=\"302\" data-mce-fragment=\"1\"\u003eCisco PWR-RGD-AC-DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eDescription\u003c\/td\u003e\n\u003ctd width=\"302\" data-mce-fragment=\"1\"\u003ePower supply, hot-plug \/ redundant (plug-in module), AC 100-240\/ DC 100-250 V, 150 Watt, for Cisco 2010, CGS 2520; Industrial Ethernet 3010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eIndustrial Ethernet 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePower Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eDimensions (HxWxD) Inches\u003c\/td\u003e\n\u003ctd width=\"302\" data-mce-fragment=\"1\"\u003e1.58 x 7 x 5 in. (4 x 17.8 x 12.7 cm) (without mounting flanges)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e2.55 lb (1.15 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eMaximum output power\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e150 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eInput current\u003c\/td\u003e\n\u003ctd width=\"302\" data-mce-fragment=\"1\"\u003eAC: 2.2 to 0.7 A, 85 to 265 VAC\u003cbr data-mce-fragment=\"1\"\u003eDC: 2.5 to 0.6 A, 88 to 300 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eTotal input BTU\u003c\/td\u003e\n\u003ctd width=\"302\" data-mce-fragment=\"1\"\u003eAC: 638 BTUs per hour\u003cbr data-mce-fragment=\"1\"\u003eDC: 750 BTUs per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eNominal input voltage\u003c\/td\u003e\n\u003ctd width=\"302\" data-mce-fragment=\"1\"\u003e100 to 240 VAC, 50 to 60 Hz\u003cbr data-mce-fragment=\"1\"\u003e100 to 250 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eAbsolute maximum (short term) input voltage\u003c\/td\u003e\n\u003ctd width=\"302\" data-mce-fragment=\"1\"\u003e85 to 265 VAC, 47 to 63 Hz\u003cbr data-mce-fragment=\"1\"\u003e88 to 300 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003cbr\u003e\u003cbr\u003e[specifications]\u003c\/p\u003e\n\u003ctable width=\"753\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eSpecifications\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003ePWR-RGD-AC-DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e40 to 140°F (40 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eUp to 10,000 ft (3049 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eRelative humidity\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003e5 to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eStandard safety certifications\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eUL 60950-1\u003cbr data-mce-fragment=\"1\"\u003eCSA C22.2 No. 60950-1\u003cbr data-mce-fragment=\"1\"\u003eTUV\/GS to EN 60950-1\u003cbr data-mce-fragment=\"1\"\u003eCB to IEC 60950-1 with all country deviations\u003cbr data-mce-fragment=\"1\"\u003eNOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eElectromagnetic emissions\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eFCC Part 15 Class A\u003cbr data-mce-fragment=\"1\"\u003eEN 55022\u003cbr data-mce-fragment=\"1\"\u003eCISPR 22\u003cbr data-mce-fragment=\"1\"\u003eCISPR11\u003cbr data-mce-fragment=\"1\"\u003eVCCI Class A\u003cbr data-mce-fragment=\"1\"\u003eAS\/NZS 3548 Class A\u003cbr data-mce-fragment=\"1\"\u003eCNS 13438 Class A\u003cbr data-mce-fragment=\"1\"\u003eKN 22 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eElectromagnetic immunity\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eEN 55024\u003cbr data-mce-fragment=\"1\"\u003eAS\/NZS CISPR 24\u003cbr data-mce-fragment=\"1\"\u003eKN 24\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-2 (Electro Static Discharge)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-3 (Radiated Immunity)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-4 (Fast Transients)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-5 (Surge)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-6 (Conducted Immunity)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-8 (Power Frequency Magnetic Field Immunity)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-9 (Pulse Magnetic Field Immunity)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-10 (Oscillatory Magnetic Field Immunity)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-11 (AC power Voltage Immunity)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-16 (Low Frequency Conducted CM Disturbances)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-17 (Ripple on DC Input Power)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-18 (Damped Oscillatory Wave)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-29 (Voltage Dips Immunity, DC power)\u003cbr data-mce-fragment=\"1\"\u003eIEEE C37.90 (Surge)\u003cbr data-mce-fragment=\"1\"\u003eIEEE C37.90.1 (Fast Transients)\u003cbr data-mce-fragment=\"1\"\u003eIEEE C37.90.2 (Radiated Immunity)\u003cbr data-mce-fragment=\"1\"\u003eIEEE C37.90.3 (Electro Static Discharge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMechanical stability\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eIEC 60628-2-27 Shock 20g (operational), 30g (nonoperational)\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eIndustry specifications\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eEN 61131-2 Programmable Controllers (EMC\/EMI, environmental, mechanical)\u003cbr data-mce-fragment=\"1\"\u003eIEEE 1613 Power Station and Substation Networking Devices\u003cbr data-mce-fragment=\"1\"\u003eIEC 61850-3 Power Station and Substation Communication Networks and Systems\u003cbr data-mce-fragment=\"1\"\u003eEN 61326-1 Electrical Equipment for Measurement, Control and Laboratory Use - EMC\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-6-1 Immunity for Light Industrial Environments\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-6-2 Immunity for Industrial Environments\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-6-4 Emissions for Industrial Environments\u003cbr data-mce-fragment=\"1\"\u003eTS 61000-6-5 EMC Immunity for Power Station and Substation\u003cbr data-mce-fragment=\"1\"\u003eEN 50155 Railway, Electronic Equipment on Rolling Stock (EMI\/EMC, environmental, mechanical)\u003cbr data-mce-fragment=\"1\"\u003eEN 50121-3-2 Railway, Electromagnetic Compatibility on Rolling Stock\u003cbr data-mce-fragment=\"1\"\u003eEN 50121-4 Railway, Emission and Immunity of Signaling and Telecommunications Apparatus\u003cbr data-mce-fragment=\"1\"\u003eEN 60945 Maritime Navigation and Radio-communication Equipment and Systems\u003cbr data-mce-fragment=\"1\"\u003eIEC 60533 Shipboard Electrical and Electronic Installation EMC\u003cbr data-mce-fragment=\"1\"\u003eMarine Type Approval (BV, DNV, Korean Register, Lloyd Register)\u003cbr data-mce-fragment=\"1\"\u003eNEMA TS-2 (EMC, environmental, mechanical)\u003cbr data-mce-fragment=\"1\"\u003eABB Industrial IT certification\u003cbr data-mce-fragment=\"1\"\u003eODVA Industrial EtherNet\/IP support\u003cbr data-mce-fragment=\"1\"\u003ePROFINETv2 support\u003cbr data-mce-fragment=\"1\"\u003eDirective 2011\/65\/EU RoHS\u003cbr data-mce-fragment=\"1\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eHazardous locations\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eUL\/CSA 60079-0, -15 (Class 1, Div 2 A-D) (requires cabinet enclosure)\u003cbr data-mce-fragment=\"1\"\u003eEN 60079-0, -15 ATEX Certification (Class 1, Zone 2 A-D) (requires cabinet enclosure)\u003cbr data-mce-fragment=\"1\"\u003eIEC 60079-0, -15 (Test report only) (requires cabinet enclosure)\u003cbr data-mce-fragment=\"1\"\u003eUL 508\u003cbr data-mce-fragment=\"1\"\u003eCSA C22.2 No. 142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eHumidity\u003c\/td\u003e\n\u003ctd width=\"369\" data-mce-fragment=\"1\"\u003eRelative humidity: 5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCisco PWR-RGD-AC-DC Power Supply\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Cisco PWR-RGD-AC-DC is a rugged High Voltage AC or DC Power Source designed with the Cisco Industrial Ethernet CGS 2520 Series, which can also be used in the CGR 2010 router. It delivers reliable and stable power with a capacity of 150W. The module is a hot plug with high PoE \/PoE+ support.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\"\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh PoE+\u003c\/li\u003e\n\u003cli\u003eOutput power 150W\u003c\/li\u003e\n\u003cli\u003eCGS 2520 Series\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe tabs contain the Cisco PWR-RGD-AC-DC datasheet with all the specifics you need.\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Cisco","offers":[{"title":"Default Title","offer_id":48013270253785,"sku":"PWR-RGD-AC-DC-NEW","price":583.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/pwr-rgd-ac-dc_1_ff9d258f-3bd6-44f0-bbcb-d65d0c0d134f.webp?v=1771853049","url":"https:\/\/www.aloinfo.com.co\/pt-br\/products\/cisco-pwr-rgd-ac-dc-power-supply-hqfpj","provider":"aloinfousa.com","version":"1.0","type":"link"}