{"product_id":"juniper-qfx10008-base-h-chassis-ri4zu","title":"Juniper QFX10008-BASE-H Chassis","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\n\u003cli\u003eQFX10008\u003c\/li\u003e\n\u003cli\u003e8-slot chassis\u003c\/li\u003e\n\u003cli\u003e3 x HVDC-capable power supplies\u003c\/li\u003e\n\u003cli\u003e2 x fan tray\u003c\/li\u003e\n\u003cli\u003e2 x fan tray controller\u003c\/li\u003e\n\u003cli\u003e5 x switch fabric cards\u003c\/li\u003e\n\u003cli\u003e1 x routing engine\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n[properties]\n\u003ctable data-mce-fragment=\"1\" width=\"588\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eProperties\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"382\"\u003eJuniper QFX10008-BASE-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eDescription\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"382\"\u003eQFX10008 Base 8-slot chassis with 1 CB, 3 HVDC capablepower supplies, 2 fan trays, 2 fan tray controllers, and 5 switch fabric cards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eQFX10008 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eBase Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003eMaximum Port Densities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMaximum 10GbE port density\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1,152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMaximum 40GbE port density\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e288\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMaximum 100GbE port density\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOperating System\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"382\"\u003eJunos OS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eArchitecture\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"382\"\u003eMidplane-less orthogonal interconnect architecture\u003cbr data-mce-fragment=\"1\"\u003e Separate dedicated data, control, and management planes\u003cbr data-mce-fragment=\"1\"\u003e Secure, modular architecture that isolates faults\u003cbr data-mce-fragment=\"1\"\u003e Transparent failover and network recovery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eControl Board\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"382\"\u003ePrimary and backup CBs (1+1 redundancy)\u003cbr data-mce-fragment=\"1\"\u003e Intel Quad Core 2.5GHz CPU\u003cbr data-mce-fragment=\"1\"\u003e 32 gigabytes SDRAM\u003cbr data-mce-fragment=\"1\"\u003e 50 gigabytes onboard SSD\u003cbr data-mce-fragment=\"1\"\u003e Pluggable solid-state drive (SSD)\u003cbr data-mce-fragment=\"1\"\u003e USB 2.0 storage interface\u003cbr data-mce-fragment=\"1\"\u003e Four SFP\/SFP+ MACsec-capable ports\u003cbr data-mce-fragment=\"1\"\u003e Fiber (SFP) or 10\/100\/1000BASE-T (RJ-45) Ethernet management port\u003cbr data-mce-fragment=\"1\"\u003e One console port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eTotal number of I\/O slots\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePower\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"382\"\u003eWith 3 HVDC-capable power supplies\u003cbr data-mce-fragment=\"1\"\u003e Holds up to six power supplies:\u003cbr data-mce-fragment=\"1\"\u003e -40 to -72 VDC\u003cbr data-mce-fragment=\"1\"\u003e 200 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eTypical Power\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1,517 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eReserved Power\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"382\"\u003e2,500 W \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMaximum Thermal Output\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"382\"\u003e48,156 BTU\/hour (14,113 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eCooling\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"382\"\u003eFront-to-back airflow\u003cbr data-mce-fragment=\"1\"\u003e Dual hot-swappable fan trays with redundant fans\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"382\"\u003e17.4 x 22.55 x 32 in\u003cbr data-mce-fragment=\"1\"\u003e (44.2 x 57.3 x 81.3 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e280 lbs (127 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eFully loaded chassis weight\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"382\"\u003e493 lbs (224 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRack units\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e13 U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/properties]\u003cbr\u003e\u003cbr\u003e[specifications]\n\u003ctable data-mce-fragment=\"1\" width=\"789\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eSpecifications\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003eQFX10008-BASE-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eSystem throughput\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003eUp to 48 Tbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eForwarding capacity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003eUp to 16 Bpps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMaximum bandwidth\/slot\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e7.2 Tbps\/slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eFabric\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003eUp to 86.4 Tbps raw fabric capacity\u003cbr data-mce-fragment=\"1\"\u003e Up to 7.2 Tbps (full duplex) per slot usable fabric capacity\u003cbr data-mce-fragment=\"1\"\u003e 5+1 fabric redundancy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eLatency\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003eAs low as 2.5 microseconds within a PFE\u003cbr data-mce-fragment=\"1\"\u003e As low as 5.5 microseconds across PFEs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eMedia access control (MAC) addresses\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eUp to 1 million\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eARP entries\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eUp to 510,000, or 64,000 per PFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eJumbo frames\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e9,216 Bytes maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eVLANs\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e4,093\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eForwarding information base (FIB) (IPv4\/IPv6)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eUp to 2 million\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eHost routes\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eUp to 2 million\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eECMP\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e64-way\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eIPv4 Multicast routes\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eUp to 128,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eIPv6 Multicast routes\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eUp to 128,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMulticast groups\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eUp to 128,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eFilters\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eUp to 8,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eFilter terms\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eUp to 64,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePolicers\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eUp to 8,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOutput queues per port\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eVirtual Output Queues\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e384,000 per PFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eLink aggregation groups (LAG)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eDistributed BFD sessions\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e200\/line card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMembers \/ LAG\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eBGP neighbors (Premium Feature License)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003e1,024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eGRE tunnels\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e2,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eVXLAN tunnels\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMPLS Layer 3 VPNs (Advanced Feature License)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003e4,096\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eLSPs (ingress\/egress\/transit) (Advanced Feature License)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003e4,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eVRFs\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003e4,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003eSoftware Features\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eLayer 2 Features\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003e802.1D  Spanning Tree Protocol (STP)\u003cbr data-mce-fragment=\"1\"\u003e 802.1w  Rapid Spanning Tree Protocol (RSTP)\u003cbr data-mce-fragment=\"1\"\u003e 802.1s  Multiple Spanning Tree Protocol (MSTP)\u003cbr data-mce-fragment=\"1\"\u003e VLAN Spanning Tree Protocol (VSTP)\u003cbr data-mce-fragment=\"1\"\u003e 802.1AB Link Layer Discovery Protocol (LLDP)\u003cbr data-mce-fragment=\"1\"\u003e VLAN Registration Protocol\u003cbr data-mce-fragment=\"1\"\u003e QinQ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eLink Aggregation\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003e802.3ad  Link Aggregation Control Protocol (LACP)\u003cbr data-mce-fragment=\"1\"\u003e Multi-chassis Link Aggregation (MC-LAG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eLayer 3 Features\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003eBGP (Premium Feature license or Advanced Feature license)\u003cbr data-mce-fragment=\"1\"\u003e Ethernet VPN (EVPN) Type 5\u003cbr data-mce-fragment=\"1\"\u003e Filter-based forwarding\u003cbr data-mce-fragment=\"1\"\u003e OSPF v1\/v2\u003cbr data-mce-fragment=\"1\"\u003e OSPF v3\u003cbr data-mce-fragment=\"1\"\u003e Virtual Router Redundancy Protocol (VRRP)\u003cbr data-mce-fragment=\"1\"\u003e IPv6\u003cbr data-mce-fragment=\"1\"\u003e Bidirectional Forwarding Detection (BFD)\u003cbr data-mce-fragment=\"1\"\u003e Virtual routers\u003cbr data-mce-fragment=\"1\"\u003e Unicast reverse path forwarding (uRPF)\u003cbr data-mce-fragment=\"1\"\u003e Loop-free alternate (LFA)\u003cbr data-mce-fragment=\"1\"\u003e IS-IS (Premium Feature license or Advanced Feature license)\u003cbr data-mce-fragment=\"1\"\u003e DHCP v4\/v6 relay\u003cbr data-mce-fragment=\"1\"\u003e VR-aware DHCP\u003cbr data-mce-fragment=\"1\"\u003e IPv4 \/ IPv6 over GRE tunnels (interface-based)\u003cbr data-mce-fragment=\"1\"\u003e Static routing\u003cbr data-mce-fragment=\"1\"\u003e RIP v1\/v2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMulticast\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003eEVPN Type 6\/7\/8\u003cbr data-mce-fragment=\"1\"\u003e Internet Group Management Protocol (IGMP) v1\/v2\/v3\u003cbr data-mce-fragment=\"1\"\u003e Multicast Listener Discovery (MLD) v1\/v2\u003cbr data-mce-fragment=\"1\"\u003e IGMP Proxy, Querier\u003cbr data-mce-fragment=\"1\"\u003e IGMP snooping\u003cbr data-mce-fragment=\"1\"\u003e MLD snooping\u003cbr data-mce-fragment=\"1\"\u003e Protocol Independent Multicast PIM-SM, PIM-SSM, PIM-DM\u003cbr data-mce-fragment=\"1\"\u003e Multicast Source Discovery Protocol (MSDP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eFirewall Filters\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003eIngress and egress L2-L4 access control lists (ACLs):\u003cbr data-mce-fragment=\"1\"\u003e - Port ACLs\u003cbr data-mce-fragment=\"1\"\u003e - VLAN ACLs\u003cbr data-mce-fragment=\"1\"\u003e - Router ACLs\u003cbr data-mce-fragment=\"1\"\u003e Control plane denial-of-service (DoS) protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eQuality of Service (QoS)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003eSingle rate three color policer\u003cbr data-mce-fragment=\"1\"\u003e Two rate three-color policer\u003cbr data-mce-fragment=\"1\"\u003e Congestion prevention:\u003cbr data-mce-fragment=\"1\"\u003e - Weighted random early detection (WRED)\u003cbr data-mce-fragment=\"1\"\u003e - Tail drop\u003cbr data-mce-fragment=\"1\"\u003e - Explicit congestion notification (ECN) marking\u003cbr data-mce-fragment=\"1\"\u003e Priority-based scheduling:\u003cbr data-mce-fragment=\"1\"\u003e - Low-latency queuing with strict high priority\u003cbr data-mce-fragment=\"1\"\u003e - Weighted round-robin (WRR) queuing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eMPLS (Advanced Feature License\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003eLDP\u003cbr data-mce-fragment=\"1\"\u003e RSVP\u003cbr data-mce-fragment=\"1\"\u003e LDP tunneling (LDP over RSVP)\u003cbr data-mce-fragment=\"1\"\u003e Fast reroute (FRR)\u003cbr data-mce-fragment=\"1\"\u003e IPv6 tunneling (6PE)\u003cbr data-mce-fragment=\"1\"\u003e Ingress, transit, and egress label-switched paths (LSPs)\u003cbr data-mce-fragment=\"1\"\u003e IPv4 Layer 3 VPNs\u003cbr data-mce-fragment=\"1\"\u003e IPv6 Layer 3 VPNs (6VPE)\u003cbr data-mce-fragment=\"1\"\u003e Layer 2 circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eOverlays (Premium Feature License or Advanced Feature License)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003eEVPN-VXLAN\u003cbr data-mce-fragment=\"1\"\u003e VXLAN L2 and L3 gateway\u003cbr data-mce-fragment=\"1\"\u003e Integration with VMware NSX SDN controller\u003cbr data-mce-fragment=\"1\"\u003e Open vSwitch Database (OVSDB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eHigh Availability\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003eGraceful Routing Engine switchover (GRES)\u003cbr data-mce-fragment=\"1\"\u003e Nonstop active routing (NSR)\u003cbr data-mce-fragment=\"1\"\u003e Nonstop bridging (NSB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eTiming\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003ePrecision Timing Protocol (PTP)\u003cbr data-mce-fragment=\"1\"\u003e - Transparent clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eVisibility\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003eSwitched Port Analyzer (SPAN)\u003cbr data-mce-fragment=\"1\"\u003e RSPAN\u003cbr data-mce-fragment=\"1\"\u003e ERSPAN\u003cbr data-mce-fragment=\"1\"\u003e Firewall filter-based port mirroring\u003cbr data-mce-fragment=\"1\"\u003e sFlow v5\u003cbr data-mce-fragment=\"1\"\u003e BGP Monitoring Protocol (BMP)\u003cbr data-mce-fragment=\"1\"\u003e IPFIX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eData Center Bridging\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003ePriority-based flow control (PFC)IEEE 802.1Qbb\u003cbr data-mce-fragment=\"1\"\u003e Data Center Bridging Exchange Protocol (DCBX), DCBx FCoE,\u003cbr data-mce-fragment=\"1\"\u003e and iSCSI type, length, and value (TLVs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eManagement and Operations\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003eJuniper Space®\u003cbr data-mce-fragment=\"1\"\u003e  Network Director for Campus\u003cbr data-mce-fragment=\"1\"\u003e Junos OS CLI via console, telnet, SSH\u003cbr data-mce-fragment=\"1\"\u003e Out-of-band management: Serial; 10\/100\/1000BASE-T\u003cbr data-mce-fragment=\"1\"\u003e Ethernet\u003cbr data-mce-fragment=\"1\"\u003e Role-based CLI management and access\u003cbr data-mce-fragment=\"1\"\u003e Junos XML management protocol\u003cbr data-mce-fragment=\"1\"\u003e ASCII configuration file\u003cbr data-mce-fragment=\"1\"\u003e SNMP v1\/v2\/v3\u003cbr data-mce-fragment=\"1\"\u003e RADIUS\u003cbr data-mce-fragment=\"1\"\u003e TACACS+\u003cbr data-mce-fragment=\"1\"\u003e Extensive MIB support\u003cbr data-mce-fragment=\"1\"\u003e Junos OS configuration rescue and rollback\u003cbr data-mce-fragment=\"1\"\u003e Image rollback\u003cbr data-mce-fragment=\"1\"\u003e OpenStack Neutron Plug-in\u003cbr data-mce-fragment=\"1\"\u003e Puppet\u003cbr data-mce-fragment=\"1\"\u003e Chef\u003cbr data-mce-fragment=\"1\"\u003e Python\u003cbr data-mce-fragment=\"1\"\u003e Junos OS event, commit and OP scripts\u003cbr data-mce-fragment=\"1\"\u003e RMON (RFC 2819): Groups 1, 2, 3, 9\u003cbr data-mce-fragment=\"1\"\u003e Network Time Protocol (NTP)\u003cbr data-mce-fragment=\"1\"\u003e SSHv2\u003cbr data-mce-fragment=\"1\"\u003e Secure copy\u003cbr data-mce-fragment=\"1\"\u003e DNS resolver\u003cbr data-mce-fragment=\"1\"\u003e System logging\u003cbr data-mce-fragment=\"1\"\u003e Environment monitoring\u003cbr data-mce-fragment=\"1\"\u003e Temperature sensor\u003cbr data-mce-fragment=\"1\"\u003e Configuration backup via FTP\/secure copy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eTroubleshooting\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003eDebugging: CLI via console, telnet, or SSH\u003cbr data-mce-fragment=\"1\"\u003e Diagnostics: Show, debug, and statistics commands\u003cbr data-mce-fragment=\"1\"\u003e Port mirroring\u003cbr data-mce-fragment=\"1\"\u003e IP tools: Extended ping and trace\u003cbr data-mce-fragment=\"1\"\u003e Juniper Networks commit and rollback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e32° to 104° F (0° to 40° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e-40° to 158° F (-40° to 70° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e Up to 10,000 ft (3,048 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRelative humidity operating\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e 5 to 90% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRelative humidity nonoperating\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e 5 to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSeismic\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003e: Designed to meet GR-63, Zone 4 earthquake requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eSafety\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003eCAN\/CSA-C22.2 No. 60950-1 Information Technology\u003cbr data-mce-fragment=\"1\"\u003e EquipmentSafety\u003cbr data-mce-fragment=\"1\"\u003e UL 60950-1 Information Technology EquipmentSafety\u003cbr data-mce-fragment=\"1\"\u003e EN 60950-1 Information Technology EquipmentSafety\u003cbr data-mce-fragment=\"1\"\u003e IEC 60950-1 Information Technology EquipmentSafety (All\u003cbr data-mce-fragment=\"1\"\u003e country deviations)\u003cbr data-mce-fragment=\"1\"\u003e EN 60825-1 Safety of Laser ProductsPart 1: Equipment\u003cbr data-mce-fragment=\"1\"\u003e Classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eElectromagnetic Compatibility\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003e47CFR Part 15, (FCC) Class A\u003cbr data-mce-fragment=\"1\"\u003e ICES-003 Class A\u003cbr data-mce-fragment=\"1\"\u003e EN 55022 Class A\u003cbr data-mce-fragment=\"1\"\u003e CISPR 22 Class A\u003cbr data-mce-fragment=\"1\"\u003e EN 55024\u003cbr data-mce-fragment=\"1\"\u003e CISPR 24\u003cbr data-mce-fragment=\"1\"\u003e EN 300 386\u003cbr data-mce-fragment=\"1\"\u003e VCCI Class A\u003cbr data-mce-fragment=\"1\"\u003e AS\/NZA CISPR22 Class A\u003cbr data-mce-fragment=\"1\"\u003e KN22 Class A\u003cbr data-mce-fragment=\"1\"\u003e CNS 13438 Class A\u003cbr data-mce-fragment=\"1\"\u003e EN 61000-3-2\u003cbr data-mce-fragment=\"1\"\u003e EN 61000-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eETSI\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"394\"\u003eETSI EN 300 019: Environmental Conditions \u0026amp; Environmental\u003cbr data-mce-fragment=\"1\"\u003e Tests for Telecommunications Equipment\u003cbr data-mce-fragment=\"1\"\u003e ETSI EN 300 019-2-1 (2000)Storage\u003cbr data-mce-fragment=\"1\"\u003e ETSI EN 300 019-2-2 (1999)Transportation\u003cbr data-mce-fragment=\"1\"\u003e ETSI EN 300 019-2-3 (2003)Stationary Use at Weatherprotected Locations\u003cbr data-mce-fragment=\"1\"\u003e ETSI EN 300 019-2-4 (2003)Stationary Use at NonWeather-protected Locations\u003cbr data-mce-fragment=\"1\"\u003e ETS 300753 (1997)Acoustic noise emitted by\u003cbr data-mce-fragment=\"1\"\u003e telecommunications equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/specifications]\u003cbr\u003e\u003cbr\u003e[accesories]\n\u003ctable data-mce-fragment=\"1\" width=\"434\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"434\" colspan=\"2\"\u003e Line Cards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eQFX10000-36Q\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eQFX10000 36-port 40GbE QSFP+ \/ 12-port 100GbE QSFP28 line card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eQFX10000-30C\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eQFX10000 30-port 100GbE QSFP28\/40GbE QSFP+ line card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eQFX10000-30C-M\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eQFX10000 30-port 100GbE QSFP28\/40GbE QSFP+ MACsec line card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eQFX10000-60S-6Q\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eQFX10000 60-port 1\/10GbE SFP\/SFP+ line card with 6 40GbE QSFP+ \/ 2 100GbE QSFP28 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eQFX10K12C-DWDM\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eQFX10000 1.2 Tbps 6-port 200GbE line rate Coherent DWDM MACsec line card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eJNP-QSFP-100G-SR4\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eQSFP28 100GBASE-SR4 Optics for up to 100 m transmission over parallel multi-mode fiber (MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eJNP-QSFP-100G-LR4\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eQSFP28 100GBASE-LR4 Optics for up to 10 km transmission over serial single-mode fiber (SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eJNP-QSFP-100G-PSM4\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eQSFP28 100GBASE-PSM4 Optics for up to 2 km transmission over parallel SMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eJNP-QSFP-100G-CWDM\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eQSFP28 100GBASE-CWDM4 Optics for up to 2 km transmission over serial SMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eJNP-QSFP-40GE-IR4\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eQSFP+ 40GBASE-IR4 40 Gigabit optics, 1,310 nm for up to 2 km transmission on SMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eJNP-QSFP-40G-LR4\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eQSFP+ 40GBASE-LR4 40 Gigabit optics, 1,310 nm for up to 10 km transmission on SMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eJNP-QSFP-40G-LX4\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eQSFP+ 40GBASE-LX4 40 Gigabit optics, 100 m (150 m) with OM3 (OM4) duplex MMF fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eJNP-QSFP-4X10GE-IR\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eQSFP+ 40GBASE Optics, up to 1.4 km transmission on parallel single mode (4X10GbE long reach up to 1.4 km)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eJNP-QSFP-4X10GE-LR\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eQSFP+ 40GBASE optics, up to 10 km transmission on parallel single mode (4X10GbE long reach up to 10 km)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eQFX-QSFP-40G-ESR4\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eQSFP+ 40GBASE-ESR4 40 Gigabit optics, 300 m (400 m) with OM3 (OM4) MMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eQFX-QSFP-40G-SR4\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eQSFP+ 40GBASE-SR4 40 Gigabit optics, 850 nm for up to 150 m transmission on MMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eQFX-SFP-10GE-LR\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP+ 10GBASE-LR 10-Gigabit Ethernet optics, 1,310 nm for 10 km transmission on SMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eQFX-SFP-10GE-SR\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP+ 10GBASE-SR 10-Gigabit Ethernet optics, 850 nm for up to 300 m transmission on MMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"434\" colspan=\"2\"\u003eSoftware Feature Licenses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eQFX10008-PFL\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eQFX10008 Premium Feature License\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eQFX10008-AFL\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eQFX10008 Advanced Feature License\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eQFX10000-30C-LFIB\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003e1 million FIB license for QFX10000-30C and QFX10000-30C-M line cards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eQFX10000-36Q-LFIB\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003e1 million FIB license for QFX10000-36Q and QFX10K-12CDWDM line cards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eQFX10000-60S-LFIB\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003e1 million FIB license for QFX10000-60S-6Q line card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"434\" colspan=\"2\"\u003e Power Cords\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eCBL-EX-PWR-C19-C20\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eAC Patch Cable - C20 PDU (16A\/250V, 2.5m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eQFX-SFP-10GE-SR\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP+ 10GBASE-SR 10-Gigabit Ethernet optics, 850 nm for up to 300 m transmission on MMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eQFX-SFP-10GE-USR\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP+ 10-Gigabit Ethernet ultra short reach optics, 850 nm for 10 m on OM1, 2 0 m on OM2, 100 m on OM3 multi-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eQFX-SFP-1GE-LX\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP 1000BASE-LX Gigabit-Ethernet optics, 1,310 nm for 10 km transmission on SMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eQFX-SFP-1GE-SX\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP 1000BASE-SX Gigabit-Ethernet optics, 850 nm for up to 550 m transmission on MMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eQFX-SFP-1GE-T\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eSFP 1000BASE-T Copper transceiver module for up to 100 m transmission on Cat5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/accesories] \u003cspan\u003eThe QFX10000 line of modular data center spine and core Ethernet switches delivers industry-leading scale, flexibility and openness, with a design that enables the seamless transition from 10GbE and 40GbE interface speeds to 100GbE. These high- performance, forward-looking switches are designed to help cloud and data center operators extract maximum value and intelligence from their network infrastructure well into the future.\u003c\/span\u003e","brand":"Juniper","offers":[{"title":"Default Title","offer_id":48013249609945,"sku":"QFX10008-BASE-H-NEW","price":85599.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/QFX10008_2eefd533-5ae1-4b4b-8d7c-e1a844fdb2de.jpg?v=1771852661","url":"https:\/\/www.aloinfo.com.co\/products\/juniper-qfx10008-base-h-chassis-ri4zu","provider":"aloinfousa.com","version":"1.0","type":"link"}