{"product_id":"juniper-acx-mic-4coc3-1coc12ce-interface-card-iergg","title":"Juniper ACX-MIC-4COC3-1COC12CE Interface Card","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\n\u003cli\u003eMultirate Circuit Emulation MIC\u003c\/li\u003e\n\u003cli\u003e4 Port Channelized OC3\/STM1 (down to DS0) or 1 Port Channelized OC12\/STM4 (down to DS0)‚ CE MIC\u003c\/li\u003e\n\u003cli\u003efor ACX4000\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n\u003cp class=\"p1\"\u003e[properties]\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003ctable border=\"1\" dir=\"ltr\" cellpadding=\"0\" cellspacing=\"0\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"222\"\u003e\n\u003ccol width=\"364\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Properties\"}'\u003eProperties\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Juniper ACX-MIC-4COC3-1COC12CE\"}'\u003eJuniper ACX-MIC-4COC3-1COC12CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Description\"}'\u003eDescription\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Multirate Circuit Emulation MIC, 4 Port Channelized OC3\/STM1 (down to DS0) or 1 Port Channelized OC12\/STM4 (down to DS0)š CE MIC, for ACX4000\"}'\u003eMultirate Circuit Emulation MIC, 4 Port Channelized OC3\/STM1 (down to DS0) or 1 Port Channelized OC12\/STM4 (down to DS0)š CE MIC, for ACX4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Product Family\"}'\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"ACX4000 Series\"}'\u003eACX4000 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Product Type\"}'\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Modular Interface Card\"}'\u003eModular Interface Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Ports\"}'\u003ePorts\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Four OC3\/STM1 ports\\n\\nRate-selectable using one of the following rates:\\n\\n4-port OC3\/STM1\\n\\n1-port OC12\/STM4\\n\\nOne channelized OC12\/STM4 port (down to DS0)\"}'\u003eFour OC3\/STM1 ports\u003cbr\u003e\u003cbr\u003eRate-selectable using one of the following rates:\u003cbr\u003e\u003cbr\u003e4-port OC3\/STM1\u003cbr\u003e\u003cbr\u003e1-port OC12\/STM4\u003cbr\u003e\u003cbr\u003eOne channelized OC12\/STM4 port (down to DS0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Weight (lb\/kg)\"}'\u003eWeight (lb\/kg)\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"1.67 lb (0.76 kg)\"}'\u003e1.67 lb (0.76 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Power requirement without PoE\"}'\u003ePower requirement without PoE\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"2.21 A @ 12 V (26.56 W)\"}'\u003e2.21 A @ 12 V (26.56 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"p1\"\u003e[\/properties][specifications]\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003ctable border=\"1\" dir=\"ltr\" cellpadding=\"0\" cellspacing=\"0\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"383\"\u003e\n\u003ccol width=\"393\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Specifications\"}'\u003eSpecifications\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"ACX-MIC-4COC3-1COC12CE\"}'\u003eACX-MIC-4COC3-1COC12CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Configurations\"}'\u003eConfigurations\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"SONET or SDH is configurable on a MIC level\\nSONET channelization:\\n\\n  -  4 OC3 channel\\n\\n  -  336 DS1 channels\\n\\n  -  2016 DS0 channels (combination of nxDS0)\\n\\nSDH channelization:\\n\\n  -  4 STM1 channel\\n\\n  -  252 E1 channels\\n\\n  -  2016 DS0 channels (combination of nxDS0)\"}'\u003eSONET or SDH is configurable on a MIC level\u003cbr\u003eSONET channelization:\u003cbr\u003e\u003cbr\u003e - 4 OC3 channel\u003cbr\u003e\u003cbr\u003e - 336 DS1 channels\u003cbr\u003e\u003cbr\u003e - 2016 DS0 channels (combination of nxDS0)\u003cbr\u003e\u003cbr\u003eSDH channelization:\u003cbr\u003e\u003cbr\u003e - 4 STM1 channel\u003cbr\u003e\u003cbr\u003e - 252 E1 channels\u003cbr\u003e\u003cbr\u003e - 2016 DS0 channels (combination of nxDS0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Software Features\"}'\u003eSoftware Features\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Per-MIC SONET\/SDH framing\\n\\nInternal and loop clocking\\n\\nEncapsulations:\\n\\n  -  Pseudo Wire Emulation Edge-to-Edge (PWE3) Architecture (RFC 3985)\\n\\n  -  Requirements for Pseudo-Wire Emulation Edge-to-Edge (PWE3) (RFC 3916)\\n\\n  -  Structure-Agnostic Time Division Multiplexing (TDM) over Packet (SAToP) (RFC 4553)\\n\\n  -  Structure-Aware Time Division Multiplexed (TDM) Circuit Emulation Service over Packet Switched Network (CESoPSN) (RFC 5086)\\n\\n  -  Pseudowire Emulation Edge-to-Edge (PWE3) Control Word for Use over an MPLS PSN (RFC 4385)\"}'\u003ePer-MIC SONET\/SDH framing\u003cbr\u003e\u003cbr\u003eInternal and loop clocking\u003cbr\u003e\u003cbr\u003eEncapsulations:\u003cbr\u003e\u003cbr\u003e - Pseudo Wire Emulation Edge-to-Edge (PWE3) Architecture (RFC 3985)\u003cbr\u003e\u003cbr\u003e - Requirements for Pseudo-Wire Emulation Edge-to-Edge (PWE3) (RFC 3916)\u003cbr\u003e\u003cbr\u003e - Structure-Agnostic Time Division Multiplexing (TDM) over Packet (SAToP) (RFC 4553)\u003cbr\u003e\u003cbr\u003e - Structure-Aware Time Division Multiplexed (TDM) Circuit Emulation Service over Packet Switched Network (CESoPSN) (RFC 5086)\u003cbr\u003e\u003cbr\u003e - Pseudowire Emulation Edge-to-Edge (PWE3) Control Word for Use over an MPLS PSN (RFC 4385)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Operating temperature\"}'\u003eOperating temperature\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"-40° to 149° F (-40° to 65° C)\"}'\u003e-40° to 149° F (-40° to 65° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Humidity\"}'\u003eHumidity\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"95% RH noncondensing\"}'\u003e95% RH noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Safety Approvals\"}'\u003eSafety Approvals\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"CAN\/CSA-C22.2 No. 60950-1\\nUL 60950-1\\nEN 60950-1\\nIEC 60950-1CB Scheme\\nEN 60825-1\"}'\u003eCAN\/CSA-C22.2 No. 60950-1\u003cbr\u003eUL 60950-1\u003cbr\u003eEN 60950-1\u003cbr\u003eIEC 60950-1CB Scheme\u003cbr\u003eEN 60825-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"EMC\"}'\u003eEMC\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"AS\/NZS CISPR22 Class A\\nEN55022 Class A\\nVCCI Class A\\nFCC Part 15 Class A\\nIECS-003 Issue 4\\nBSMI CNS 13438 and NCC C6357 Taiwan Radiated Emissions\\nKN 22, Class A\\nCISPR 32\/EN55032: 2012 European Radiated Emissions Class A\\nEN-61000-4-6 Low Frequency Common Immunity\\nEN-61000-4-11 Voltage Dips and Sags\\nCISPR 24\/EN55024 Information Technology Equipment Immunity Characteristics\"}'\u003eAS\/NZS CISPR22 Class A\u003cbr\u003eEN55022 Class A\u003cbr\u003eVCCI Class A\u003cbr\u003eFCC Part 15 Class A\u003cbr\u003eIECS-003 Issue 4\u003cbr\u003eBSMI CNS 13438 and NCC C6357 Taiwan Radiated Emissions\u003cbr\u003eKN 22, Class A\u003cbr\u003eCISPR 32\/EN55032: 2012 European Radiated Emissions Class A\u003cbr\u003eEN-61000-4-6 Low Frequency Common Immunity\u003cbr\u003eEN-61000-4-11 Voltage Dips and Sags\u003cbr\u003eCISPR 24\/EN55024 Information Technology Equipment Immunity Characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"ETSI (European Telecommunications Standardization Institute)\"}'\u003eETSI (European Telecommunications Standardization Institute)\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"EN 300 386 V1.6.1 Telecommunication Network Equipment, Electromagnetic Compatibility Requirements\\nETSI EN 300 019-2-1 (2000) Storage, Class T1.2\\nETSI EN 300 019-2-2 (1999) Transportation, Class T2.3\\nETSI EN 300 019-2-4 (2003) Stationary Use at Non-Weather Protected Locations, Class 4.1 \\nETSI 300753 (1997) Acoustic Noise Emitted by Telecommunications Equipment \"}'\u003eEN 300 386 V1.6.1 Telecommunication Network Equipment, Electromagnetic Compatibility Requirements\u003cbr\u003eETSI EN 300 019-2-1 (2000) Storage, Class T1.2\u003cbr\u003eETSI EN 300 019-2-2 (1999) Transportation, Class T2.3\u003cbr\u003eETSI EN 300 019-2-4 (2003) Stationary Use at Non-Weather Protected Locations, Class 4.1 \u003cbr\u003eETSI 300753 (1997) Acoustic Noise Emitted by Telecommunications Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"NEBS\"}'\u003eNEBS\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"SR-3580 NEBS Criteria Levels (Level 3 Compliance)\\nGR-63-CORE: NEBS, Physical Protection\\nGR-1089-CORE: EMC and Electrical Safety for Network Telecommunications Equipment (Issue 6 compliant)\\nGR-3108-CORE: Generic Requirements for Network Equipment in the Outside Plant (OSP)\"}'\u003eSR-3580 NEBS Criteria Levels (Level 3 Compliance)\u003cbr\u003eGR-63-CORE: NEBS, Physical Protection\u003cbr\u003eGR-1089-CORE: EMC and Electrical Safety for Network Telecommunications Equipment (Issue 6 compliant)\u003cbr\u003eGR-3108-CORE: Generic Requirements for Network Equipment in the Outside Plant (OSP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Telecomm Compliance\"}'\u003eTelecomm Compliance\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"T1 and XDSL Interfaces FCC Part 68 (T1 Only)\\nIndustry Canada CS-03\\nJATE Green Book\\nE1 Interface TBR 12\/13\\nACA TS016 \\nG.703 \\nRTTE Directive 1995\/5\/EC\\nDevice management: NETCONF, CLI, SNMP v1\/v2\/v3\\nEnd-to-end provisioning of E-Line, emulated LAN (ELAN), Layer 3 VPN (L3VPN), OAM, class of service (CoS)\\nDevice and service-level fault management\\nDevice and service-level performance management\"}'\u003eT1 and XDSL Interfaces FCC Part 68 (T1 Only)\u003cbr\u003eIndustry Canada CS-03\u003cbr\u003eJATE Green Book\u003cbr\u003eE1 Interface TBR 12\/13\u003cbr\u003eACA TS016 \u003cbr\u003eG.703 \u003cbr\u003eRTTE Directive 1995\/5\/EC\u003cbr\u003eDevice management: NETCONF, CLI, SNMP v1\/v2\/v3\u003cbr\u003eEnd-to-end provisioning of E-Line, emulated LAN (ELAN), Layer 3 VPN (L3VPN), OAM, class of service (CoS)\u003cbr\u003eDevice and service-level fault management\u003cbr\u003eDevice and service-level performance management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Metro Ethernet Forum (MEF)\"}'\u003eMetro Ethernet Forum (MEF)\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"MEF CE2.0 compliant\"}'\u003eMEF CE2.0 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"p1\"\u003e[\/specifications][accesories] [\/accesories]\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eJuniper ACX4000 Universal Metro Router is a 2.5 U, actively cooled access router that is environmentally hardened for field deployment. This versatile, high-performance mobile access platform runs on the Junos operating system.\u003c\/span\u003e\u003c\/p\u003e","brand":"Juniper","offers":[{"title":"Default Title","offer_id":48013239550169,"sku":"ACX-MIC-4COC3-1COC12CE-NEW","price":21658.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/ACX-MIC-4COC3-1COC12CE_f5b234b2-2be1-4d34-9f17-d54f2e422846.jpg?v=1771852488","url":"https:\/\/www.aloinfo.com.co\/products\/juniper-acx-mic-4coc3-1coc12ce-interface-card-iergg","provider":"aloinfousa.com","version":"1.0","type":"link"}