{"product_id":"endress-hauser-6aab-proline-t-mass-a150-thermal-mass-flowmeter","title":"Endress+Hauser 6AAB Proline t-mass A150 thermal mass flowmeter","description":"\u003ch1\u003eOverview\u003c\/h1\u003e\u003cp\u003eEndress+Hauser Proline t-mass A150 thermal mass flowmeter is a flowmeter for cost-effective measurement and easy monitoring of utility gases.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecs at a glance\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e* Max. measurement error\u003cbr\u003e3 % o.r.\u003cbr\u003e4 % o.r.\u003cbr\u003e5 % o.f.s.\u003cbr\u003e(depending on chosen option of ordering feature \"Calibration flow\")\u003cbr\u003e* Measuring range\u003cbr\u003e0.5 to 910 kg\/h (1.1 to 2002 lb\/h)\u003cbr\u003e0.5 to 1365 kg\/h (1.1 to 3003 lb\/h)\u003cbr\u003e(for air, depending on chosen option of ordering feature \"Calibration flow\")\u003cbr\u003e* Medium temperature range\u003cbr\u003e–40 to +100 °C (–40 to +212 °F)\u003cbr\u003e* Max. process pressure\u003cbr\u003ePN 40, Class 300\u003cbr\u003e* Wetted materials\u003cbr\u003eTransducer: 1.4404 (316L)\u003cbr\u003eInsertion tube: 1.4404 (316L)\u003cbr\u003eMeasuring tube: 1.4404 (316L); 1.4435 (316L)\u003cbr\u003eConnection: 1.4404 (F316\/F316L); 1.4404 (316L); 1.4435 (316L) \u003cbr\u003e \u003c\/p\u003e\u003ch1\u003eField of application\u003c\/h1\u003e\u003cp\u003eThe t-mass A 150 inline device is specially designed for the cost-effective measurement of utility gases, in particular compressed air. It is a trending device aimed at subetering applications. its 4-wire technology is contained within a rugged compact aluminum housing. It is orderable either with display or as a blind version. Customer-specific settings are saved on the display and can be transferred from one device to another by means of the display.\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e* Measuring principle is characterized by a high operable flow range and direct mass flow measurement\u003cbr\u003e* Suitable for air, nitrogen, carbon dioxide and argon in small line sizes.\u003cbr\u003eDevice properties\u003cbr\u003e* Inline version: nominal diameter DN 15 to 50 (1\/2 to 2\")\u003cbr\u003e* Process pressure up to PN 40, Class 300\u003cbr\u003e* A variety of process connections available\u003cbr\u003e* Device in compact version with DC 24 V power supply\u003cbr\u003e* 4-20 mA HART, pulse\/frequency\/switch output\u003cbr\u003e* Compact and robust transmitter\u003c\/p\u003e\u003ch1\u003eBenefits\u003c\/h1\u003e\u003cp\u003e* Suitable for air, nitrogen, carbon dioxide and argon in small line sizes\u003cbr\u003e* Optimal process monitoring – easy measurement even at low pressures and flow velocities\u003cbr\u003e* Cost-effective measurement – easy installation, negligible pressure loss and maintenance-free\u003cbr\u003e* Reliable flow trending – multivariable measurement\u003cbr\u003e* Fast and efficient commissioning – guided operating menus\u003cbr\u003e* High plant availability – self-diagnostics and error monitoring\u003cbr\u003e* Automatic recovery of data for servicing\u003c\/p\u003e\u003ch1\u003eSpecification\u003c\/h1\u003e\u003cfigure class=\"table\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasuring Principle\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProduct Headline\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eThe flowmeter for cost-effective measurement and easy monitoring of utility gases. \u003cbr\u003eSuitable for air, nitrogen, carbon dioxide and argon in small line sizes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor Features\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOptimal process monitoring – easy measurement even at low pressures and flow velocities. Cost-effective measurement – easy \u003cbr\u003einstallation, negligible pressure loss and maintenance-free. Reliable flow trending – multivariable measurement. \u003cbr\u003eInline version: DN 15 to 50 (½ to 2\"). Process pressure up to PN 40, Class 300. A variety of process connections available.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eTransmitter Features\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFast and efficient commissioning – guided operating menus. High plant availability – self‐diagnostics and error monitoring. \u003cbr\u003eAutomatic recovery of data for servicing. \u003cbr\u003eDevice in compact version with DC 24 V power supply. 4-20 mA HART, pulse\/frequency\/switch output. Compact and robust transmitter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eNominal Diameter Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDN 15 to 50 (½ to 2\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWetted Materials\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eTransducer: 1.4404 (316L) \u003cbr\u003eInsertion tube: 1.4404 (316L) \u003cbr\u003eMeasuring tube: 1.4404 (316L); 1.4435 (316L) \u003cbr\u003eConnection: 1.4404 (F316\/F316L); 1.4404 (316L); 1.4435 (316L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasured Variables\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMass flow, temperature, corrected volume flow, FAD volume flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMax. Measurement Error\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e3 % o.r. \u003cbr\u003e4 % o.r. \u003cbr\u003e5 % o.f.s. \u003cbr\u003e(depending on chosen option of ordering feature \"Calibration flow\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e0.5 to 910 kg\/h (1.1 to 2002 lb\/h) \u003cbr\u003e0.5 to 1365 kg\/h (1.1 to 3003 lb\/h) \u003cbr\u003e(for air, depending on chosen option of ordering feature \"Calibration flow\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMax. Process Pressure\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePN 40, Class 300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMedium Temperature Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e–40 to +100 °C (–40 to +212 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e–40 to +60 °C (–40 to +140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eTransmitter Housing Material\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAlSi10Mg, coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDegree Of Protection\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eIP66\/67, type 4X enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDisplay\/Operation\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4‐line display with push Buttons \u003cbr\u003eConfiguration via local display and operating tools possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOutputs\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4‐20 mA HART (active) \u003cbr\u003ePulse\/frequency\/switch output (passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eInputs\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eStatus input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDigital Communication\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eHART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDC 18 to 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eHazardous Area Approvals\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eATEX, IECEx, cCSAus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMetrological Approvals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCalibration performed on accredited calibration facilities (acc. to ISO\/IEC 17025), NAMUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePressure Approvals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePED, CRN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/figure\u003e\u003cp\u003e \u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":48020369998041,"sku":null,"price":2562.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/Endress_Hauser_6AAB_Proline_t-mass_A_150_thermal_mass_flowmeter.png?v=1771970636","url":"https:\/\/www.aloinfo.com.co\/products\/endress-hauser-6aab-proline-t-mass-a150-thermal-mass-flowmeter","provider":"aloinfousa.com","version":"1.0","type":"link"}