{"product_id":"dell-poweredge-r650-server","title":"Dell PowerEdge R650 Server","description":"\u003cdiv class=\"head-content-set-outer\"\u003e\n\u003ch2 class=\"Dell_PowerEdge_R630_Specifications\"\u003eCloud Ninjas' Dell PowerEdge R650 Specifications\u003c\/h2\u003e\n\u003c!-- Chassis Section Order 1 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eChassis\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003cp\u003eThe Dell PowerEdge R650 is a powerful 1U server in Dell’s 15th generation of servers. The PowerEdge R650 builds upon the 14th generation’s R640. The main differences between each R650 chassis are in the bay counts, chassis rear, and PCIe slots.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eBay Counts\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe PowerEdge R650 has four total options when it comes to bay counts and form factors. These options are 4 Bay LFF, 8 Bay SFF SAS\/SATA, 8 Bay SFF NVMe, and 10 Bay SFF SAS\/SATA or NVMe. The 4 Bay LFF, accepts four 3.5” drives in the front. The 8 Bay SFF SAS\/SATA chassis accepts eight 2.5” SAS and\/or SATA drives. The backplane for this chassis does not support NVMe drives. The 8 Bay SFF NVMe chassis accepts a total of eight 2.5” NVMe drives in the front. Lastly, the 10 Bay SFF SAS\/SATA or NVMe chassis accepts a total of ten SAS, SATA, and\/or NVMe drives in the front.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eChassis Rear\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eFor the rear of the R650, all of the ports are the same for all options. The differences have to do with whether the system has rear drive bays, the length and number of PCIe brackets, and whether it has a hot-swap BOSS card. The first possible configuration has three low profile PCIe and a hot-plug BOSS card. The second configuration has two 2.5” rear drive bays, one low profile PCIe, and a hot-plug BOSS card. The last possible rear configuration for the R650 has no rear drive bays, no hot-plug BOSS card, and two full-height PCIe.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003ePCIe Slots\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe PowerEdge R650’s PCIe slot configuration depends on the system’s rear configuration. For the first rear configuration, there is a total of three low-profile Gen 4 PCIe slots. For the second rear configuration, there is one PCIe Gen 4 slot. For the last rear configuration, there is two full-height PCIe Gen 4 slots.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Processing Power Section Order 2 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eProcessing Power\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003cp\u003eThe Dell PowerEdge R650 Server has two CPU sockets which accepts 3rd Generation Intel Xeon Scalable Processors. A maximum of 40 cores per processor can be achieved, meaning that the R650 supports 80 total cores! This makes this server an excellent choice for virtualization applications.\u003c\/p\u003e\n\u003cdiv class=\"outercontainerOfThreeTable\"\u003e\n\u003cdiv class=\"outercontainerOfOneTable\"\u003e\n\u003ch4 class=\"sub-title\"\u003eIntel Xeon Silver\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCPU\u003c\/th\u003e\n\u003cth\u003eCores\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eCache\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e4309Y\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e2.80 GHz\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4310\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e2.10 GHz\u003c\/td\u003e\n\u003ctd\u003e18 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4310T\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e2.30 GHz\u003c\/td\u003e\n\u003ctd\u003e15 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4314\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e2.40 GHz\u003c\/td\u003e\n\u003ctd\u003e24 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4316\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e2.30 GHz\u003c\/td\u003e\n\u003ctd\u003e30MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"outercontainerOfOneTable\"\u003e\n\u003ch4 class=\"sub-title\"\u003eIntel Xeon Gold\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCPU\u003c\/th\u003e\n\u003cth\u003eCores\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eCache\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e5315Y\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e3.20GHz\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5317\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e3.00GHz\u003c\/td\u003e\n\u003ctd\u003e18 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5318N\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e2.10GHz\u003c\/td\u003e\n\u003ctd\u003e36 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5318S\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e2.10 GHz\u003c\/td\u003e\n\u003ctd\u003e36 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5318Y\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e2.10 GHz\u003c\/td\u003e\n\u003ctd\u003e36 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5320\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e2.20 GHz\u003c\/td\u003e\n\u003ctd\u003e39 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5320T\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e2.30 GHz\u003c\/td\u003e\n\u003ctd\u003e30 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6312U\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e2.40 GHz\u003c\/td\u003e\n\u003ctd\u003e36 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6314U\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e2.30GHz\u003c\/td\u003e\n\u003ctd\u003e48 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6326\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e2.90 GHz\u003c\/td\u003e\n\u003ctd\u003e24 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6330\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e2.00 GHz\u003c\/td\u003e\n\u003ctd\u003e42 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6330N\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e2.20 GHz\u003c\/td\u003e\n\u003ctd\u003e42 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6334\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e3.60 GHz\u003c\/td\u003e\n\u003ctd\u003e18 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6336Y\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e2.40 GHz\u003c\/td\u003e\n\u003ctd\u003e36 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6338\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e2.00 GHz\u003c\/td\u003e\n\u003ctd\u003e48 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6338N\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e2.20 GHz\u003c\/td\u003e\n\u003ctd\u003e48 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6338T\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e2.10 GHz\u003c\/td\u003e\n\u003ctd\u003e36 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6342\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e2.80 GHz\u003c\/td\u003e\n\u003ctd\u003e36 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6346\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e3.10 GHz\u003c\/td\u003e\n\u003ctd\u003e36 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6348\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e2.60 GHz\u003c\/td\u003e\n\u003ctd\u003e42 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6354\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e3.00 GHz\u003c\/td\u003e\n\u003ctd\u003e39 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6330H\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e2.00 GHz\u003c\/td\u003e\n\u003ctd\u003e33 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5318H\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e2.50 GHz\u003c\/td\u003e\n\u003ctd\u003e24.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5320H\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e2.40 GHz\u003c\/td\u003e\n\u003ctd\u003e27.5 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6328H\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e2.80 GHz\u003c\/td\u003e\n\u003ctd\u003e22 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6328HL\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e2.80 GHz\u003c\/td\u003e\n\u003ctd\u003e22 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6348H\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e2.30 GHz\u003c\/td\u003e\n\u003ctd\u003e33 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"outercontainerOfOneTable\"\u003e\n\u003ch4 class=\"sub-title\"\u003eIntel Xeon Platinum\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCPU\u003c\/th\u003e\n\u003cth\u003eCores\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eCache\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e8351N\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e2.40GHz\u003c\/td\u003e\n\u003ctd\u003e54 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8352M\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e2.30GHz\u003c\/td\u003e\n\u003ctd\u003e48 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8352S\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e2.20GHz\u003c\/td\u003e\n\u003ctd\u003e48 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8352V\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e2.10 GHz\u003c\/td\u003e\n\u003ctd\u003e54 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8352Y\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e2.20 GHz\u003c\/td\u003e\n\u003ctd\u003e48 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8358\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e2.60 GHz\u003c\/td\u003e\n\u003ctd\u003e48 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8358P\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e2.60 GHz\u003c\/td\u003e\n\u003ctd\u003e48 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8360Y\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e2.40 GHz\u003c\/td\u003e\n\u003ctd\u003e54 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8362\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e2.80GHz\u003c\/td\u003e\n\u003ctd\u003e48 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8368\u003c\/td\u003e\n\u003ctd\u003e38\u003c\/td\u003e\n\u003ctd\u003e2.40 GHz\u003c\/td\u003e\n\u003ctd\u003e57 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8368Q\u003c\/td\u003e\n\u003ctd\u003e38\u003c\/td\u003e\n\u003ctd\u003e2.60 GHz\u003c\/td\u003e\n\u003ctd\u003e57 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8380\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e2.30 GHz\u003c\/td\u003e\n\u003ctd\u003e60 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8356H\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e3.90 GHz\u003c\/td\u003e\n\u003ctd\u003e35.75 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8360H\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e3.00 GHz\u003c\/td\u003e\n\u003ctd\u003e33 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8360HL\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e3.00 GHz\u003c\/td\u003e\n\u003ctd\u003e33 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8353H\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e2.50 GHz\u003c\/td\u003e\n\u003ctd\u003e24.75 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8354H\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e3.10 GHz\u003c\/td\u003e\n\u003ctd\u003e24.75 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8376H\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e2.60 GHz\u003c\/td\u003e\n\u003ctd\u003e38.5 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8376HL\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e2.60 GHz\u003c\/td\u003e\n\u003ctd\u003e38.5 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8380H\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e2.90 GHz\u003c\/td\u003e\n\u003ctd\u003e38.5 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8380HL\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e2.90 GHz\u003c\/td\u003e\n\u003ctd\u003e38.5 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Memory Section Order 3 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eMemory\u003c\/h3\u003e\n\u003cp class=\"head-content-set-content\"\u003eThe Dell PowerEdge R650 server has a total of 32 DDR4 DIMM slots. The R650 accepts three types of memory, which are: ECC Registered (RDIMM), Load Reduced (LRDIMM), or Intel Optane Persistent Memory (PMem) 200 Series. Module capacities of 8GB, 16GB, 32GB, 64GB, and 128GB, and 256GB, 512GB can be used within this system. 128GB and 256GB modules can only be used with Load Reduced Memory. 512GB on the other hand, can only be used with Intel Optane memory. With LRDIMMs and Intel PMem, you can reach an overall greater capacity than if you were to use RDIMMs. With RDIMMs, the maximum possible RAM you can reach is 2048GB with a 32x64GB configuration. With LRDIMMs, you can reach a max capacity of 8192GB with a configuration of 32x256GB. Lastly, for Intel PMem, the maximum total capacity you can achieve is 8192GB. The PowerEdge R650 accepts memory speeds of 2666MT\/s, 2933MT\/s, and 3200MT\/s. It is important to know, that the processor that you install will determine the maximum memory speed that the R650 will support. The highest possible speed you can achieve is 3200MT\/s. If you’re using a processor that has a lower maximum speed, and you install a module with a higher speed than the max, the speed of the module will clock down to the max speed. For example, if your processor supports a maximum memory speed of 2933MT\/s, and you install a 3200MT\/s module, that modules will run at 2933MT\/s.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Storage Section Order 4 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eStorage\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003cp\u003eThe Dell PowerEdge R650 server has a great range of different potential storage options. The chassis and form factor of your server will determine whether you can use 2.5” or 3.5” drives. There are chassis options for four 3.5” drives, eight 2.5” drives, and ten 2.5” drives. There are also chassis that allow you to add in two 2.5” drives into the rear of the system. The R650 can accept HDDs, SSDs, M.2, and uSDs drives. The supported drive interfaces are: SATA, SAS, and NVMe.\u003c\/p\u003e\n\u003ch4 class=\"sub-title\"\u003e\u003cstrong\u003eSupported Drives\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eForm Factor\u003c\/th\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eSpeed\u003c\/th\u003e\n\u003cth\u003eRotational Speed\u003c\/th\u003e\n\u003cth\u003eMax Capacity Per Drive\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3.5\"\u003c\/td\u003e\n\u003ctd\u003eSATA\u003c\/td\u003e\n\u003ctd\u003e6 Gb\u003c\/td\u003e\n\u003ctd\u003e7.2 K\u003c\/td\u003e\n\u003ctd\u003e18 TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3.5\"\u003c\/td\u003e\n\u003ctd\u003eSAS\u003c\/td\u003e\n\u003ctd\u003e12 Gb\u003c\/td\u003e\n\u003ctd\u003e7.2 K\u003c\/td\u003e\n\u003ctd\u003e18 TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2.5\"\u003c\/td\u003e\n\u003ctd\u003eSATA\u003c\/td\u003e\n\u003ctd\u003e6 Gb\u003c\/td\u003e\n\u003ctd\u003eSSD\u003c\/td\u003e\n\u003ctd\u003e3.84 TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2.5\"\u003c\/td\u003e\n\u003ctd\u003eSAS\u003c\/td\u003e\n\u003ctd\u003e12 Gb\u003c\/td\u003e\n\u003ctd\u003e10 K\u003c\/td\u003e\n\u003ctd\u003e2.4 TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2.5\"\u003c\/td\u003e\n\u003ctd\u003eSAS\u003c\/td\u003e\n\u003ctd\u003e12 Gb\u003c\/td\u003e\n\u003ctd\u003e15 K\u003c\/td\u003e\n\u003ctd\u003e900 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2.5\"\u003c\/td\u003e\n\u003ctd\u003eSAS\u003c\/td\u003e\n\u003ctd\u003e12 Gb\u003c\/td\u003e\n\u003ctd\u003eSSD\u003c\/td\u003e\n\u003ctd\u003e15.36 TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM.2\u003c\/td\u003e\n\u003ctd\u003eSATA\u003c\/td\u003e\n\u003ctd\u003e6 Gb\u003c\/td\u003e\n\u003ctd\u003eSSD\u003c\/td\u003e\n\u003ctd\u003e480GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003euSD\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003euSD\u003c\/td\u003e\n\u003ctd\u003e64GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2.5\" (U.2)\u003c\/td\u003e\n\u003ctd\u003eNVMe\u003c\/td\u003e\n\u003ctd\u003eGen4\u003c\/td\u003e\n\u003ctd\u003eSSD\u003c\/td\u003e\n\u003ctd\u003e7.68TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2.5\" (U.2)\u003c\/td\u003e\n\u003ctd\u003eNVMe\u003c\/td\u003e\n\u003ctd\u003eGen3\u003c\/td\u003e\n\u003ctd\u003eSSD\u003c\/td\u003e\n\u003ctd\u003e7.68TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Storage Section Order 4 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eNVMe Options \u0026amp; Upgrades\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003cp\u003eNVMe is in extreme demand in enterprise environments, and it’s for good reason. NVMe drives outperform most mechanical hard drives and non-NVMe drives. NVMe drives are super-fast which makes them optimal in certain environments. In the past, we have tested systems on three types of NVMe solutions, which are: U.2, PCIe, and M.2.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eU.2 NVMe and Backplane NVMe\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eWith some of the older systems we’ve tested, we have been able to install a U.2 NVMe enablement kit, which allowed a portion of the system’s backplane to accept NVMe drives. If you have an 8 bay chassis with an NVMe capable backplane, or a 10 bay chassis, then you’re in luck. With these chassis, you don’t even need an NVMe enablement kit, as the backplane has NVMe support out of the box. If these systems have rear drive bays, then you can install NVMe drives as well. For the 10 bay chassis, CPU 2 will control the first four drive bays and CPU 1 will control the last six drive bays as well as any drive bays in the rear. One thing to note is that installing ten NVMe drives into all ten drive bays will limit your I\/O availability since one I\/O slot will be in use so it can enable the last two NVMe drives. The 4 Bay LFF chassis does not have an NVMe capable backplane, but if you have a rear drive kit, then you can install two 2.5” NVMe drives into the back of your server.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eM.2 NVMe\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eA maximum of two M.2 NVMe drives can be installed into the Dell PowerEdge R650 with a Dell BOSS-S2 controller card. The R650 has the ability to use the Dell BOSS-S1 adapter as well. One advantage that the BOSS-S2 card has over the BOSS-S1 is that the BOSS-S2 allows you to hot swap M.2 drives. This is super convenient in the event that there is a drive failure. Both the BOSS-S1 and BOSS-S2 support hardware RAID.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Systems Management Solutions Section Order 7 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003ePower Supplies\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003ch4\u003e\u003cstrong\u003eHow Many Power Supplies does the R650 Take?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Dell PowerEdge R650 server can hold up to two hot-swap power supplies. The units being hot swap means that you can remove or add a power supply while the server is powered on. To this, one power supply must remain within the system. The location of the PSU slots differ from the R640 as there is one on each side of the server. The power supply bays are spread apart instead of being adjacent to eachother. Dell designed the server like this, to enhance the cooling capabilities of the server and improve the airflow.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eWattage Options\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThere is a total of three wattage options for the PowerEdge R650 server. These options are 800W, 1100W, and 1400W. Each of these are awesome options, but for more power intensive applications, stick with either 1100W and 1400W options. And for servers that can’t afford to have down time, utilize two units, so if one fails, the other can keep the system up and running, until the failed unit is replaced.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eFor voltages, power supply voltage options, 800W, 1100W, and 1400W all have mixed mode options. This allows the power supply to support an overall greater voltage range. Mixed mode power supplies allow for a voltage range of 100W-240W. With a mixed mode power supply, you can use both 110V and 220V connections. Once thing to note, that when using either a 1100W or 1400W mixed mode power supply, operating on a voltage of 100V-120V, the wattage will decrease to 1050W. There is also a 1100W DC -48V-60V power supply option.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Storage Section Order 5 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eRAID Options\u003c\/h3\u003e\n\u003cp class=\"head-content-set-content\"\u003eThe Dell PowerEdge R650 supports a wide range of storage controllers. There are both RAID (PERC) and non-RAID options. Both of these options are good options, but depending on what you need, one may be a better choice than the other. There is also an option to use software RAID. Non-RAID adapters do not have the ability to set up RAID, but they can be used as a boot controller as well as a data controller. PERC RAID controllers on the other hand allows you to set your drives up in a RAID array. A software RAID does the same thing, but it is more limited than a hardware RAID.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eRAID Options\u003c\/th\u003e\n\u003cth\u003eRAID Levels\u003c\/th\u003e\n\u003cth\u003eCache\u003c\/th\u003e\n\u003cth\u003eDrive Speeds\u003c\/th\u003e\n\u003cth\u003ePCIe Generation\u003c\/th\u003e\n\u003cth\u003eRAID Hardware\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eS150 onboard software\u003c\/td\u003e\n\u003ctd\u003e0,1,5,10\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e6 Gb\/s SATA\/NVMe\u003c\/td\u003e\n\u003ctd\u003ePCIe\u003c\/td\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHBA355E\u003c\/td\u003e\n\u003ctd\u003ePassthrough\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e3 Gb\/s SAS\/SATA\u003cbr\u003e6 Gb\/s SAS\/SATA\u003cbr\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 4.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHBA355i\u003c\/td\u003e\n\u003ctd\u003ePassthrough\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e3 Gb\/s SAS\/SATA\u003cbr\u003e6 Gb\/s SAS\/SATA\u003cbr\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 4.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH345\u003c\/td\u003e\n\u003ctd\u003e0,1,10\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e3 Gb\/s SAS\/SATA\u003cbr\u003e6 Gb\/s SATA\u003cbr\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 3.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH355\u003c\/td\u003e\n\u003ctd\u003e0,1,10\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e6 Gb\/s SATA \u003cbr\u003e 12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 4.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH745\u003c\/td\u003e\n\u003ctd\u003e0,1,5,6,10,50,60\u003c\/td\u003e\n\u003ctd\u003e4GB NV\u003c\/td\u003e\n\u003ctd\u003e3 Gb\/s SAS\/SATA\u003cbr\u003e6 Gb\/s SATA\u003cbr\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 3.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH755\u003c\/td\u003e\n\u003ctd\u003e0,1,5,6,10,50,60\u003c\/td\u003e\n\u003ctd\u003e8GB NV\u003c\/td\u003e\n\u003ctd\u003eGen4 (16 GT\/s) NVMe\u003cbr\u003eGen3 (8 GT\/s) NVMe\u003cbr\u003e3 Gb\/s SAS\/SATA\u003cbr\u003e6 Gb\/s SAS\/SATA\u003cbr\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 4.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH755N\u003c\/td\u003e\n\u003ctd\u003e0,1,5,6,10,50,60\u003c\/td\u003e\n\u003ctd\u003e8GB NV\u003c\/td\u003e\n\u003ctd\u003eGen4 (16 GT\/s) NVMe\u003cbr\u003eGen3 (8 GT\/s) NVMe\u003c\/td\u003e\n\u003ctd\u003ePCIe 4.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH840\u003c\/td\u003e\n\u003ctd\u003e0,1,5,6,10,50,60\u003c\/td\u003e\n\u003ctd\u003e8GB NV\u003c\/td\u003e\n\u003ctd\u003e6 Gb\/s SATA\u003cbr\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 3.1\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c!-- Network Interface Card Options Section Order 6 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eNetwork Interface Card Options\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003cp\u003eThe Dell PowerEdge R650 has many different choices to choose from in terms of network cards. Unlike the R640, the R650 does not support Dell daughter cards anymore. Dell has moved to a new standard called “OCP”.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eNetwork Card Options\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDell Broadcom 57416 Dual Port 10GbE RJ45 OCP 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDell Broadcom 57412 Dual Port 10GbE SFP+ OCP 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDell Broadcom 57414 Dual Port 25GbE SFP28 OCP 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDell Broadcom 5720 Quad Port 1GbE RJ45 OCP 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDell Intel X710 Dual Port 10GbE SFP+ OCP 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDell Intel X710-T2L Dual Port 10GbE RJ45 OCP 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDell Intel X710-T4 Quad Port 10GbE RJ45 OCP 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDell Intel X710 Quad Port 10GbE SFP+ OCP 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDell Intel X710-T2L Dual Port 10GbE RJ45 OCP 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDell Intel E810-XXV Dual Port 25GbE SFP28 OCP 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDell Mellanox ConnectX-5 Dual Port 25GbE SFP28 OCP 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDell Marvell FastLinQ 41132 Dual Port 10GbE SFP+ OCP 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDell Qlogic 41232 Dual Port 25GbE SFP28 OCP 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Systems Management Solutions Section Order 7 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eSystems Management Solutions\u003c\/h3\u003e\n\u003cp class=\"head-content-set-content\"\u003eThe Dell PowerEdge has a ton of system management and support options. These options include but are not limited to: LC 4.x, OpenManage, QuickSync2.0, Digital License Key, iDRAC Direct, and Easy Restore.\u003c\/p\u003e\n\u003cul class=\"custom_dots\"\u003e\n\u003cli\u003e⦿ Integrated Dell Remote Access Controller (iDRAC 9)\u003c\/li\u003e\n\u003cli\u003e⦿ iDRAC Service Module (iSM)\u003c\/li\u003e\n\u003cli\u003e⦿ OpenManage Ansible Modules\u003c\/li\u003e\n\u003cli\u003e⦿ OpenManage Essentials (OME)\u003c\/li\u003e\n\u003cli\u003e⦿ OpenManage Mobile (OMM)\u003c\/li\u003e\n\u003cli\u003e⦿ OpenManage Integration for VMware vCenter (OMIVV)\u003c\/li\u003e\n\u003cli\u003e⦿ OpenManage Integration for Microsoft System Center (OMIMSSC)\u003c\/li\u003e\n\u003cli\u003e⦿ Dell EMC Repository Manager (DRM)\u003c\/li\u003e\n\u003cli\u003e⦿ Dell EMC System Update (DSU)\u003c\/li\u003e\n\u003cli\u003e⦿ Dell EMC Platform Specific Bootable ISO (PSBI)\u003c\/li\u003e\n\u003cli\u003e⦿ Dell EMC Chassis Management Controller (CMC)\u003c\/li\u003e\n\u003cli\u003e⦿ OpenManage Connections for Partner Consoles\u003c\/li\u003e\n\u003cli\u003e⦿ OpenManage Enterprise Power Manager\u003c\/li\u003e\n\u003cli\u003e⦿ OpenManage Integration with ServiceNow (OMISNOW)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- Systems Management Solutions Section Order 8 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eSupported Operating Systems:\u003c\/h3\u003e\n\u003cp class=\"head-content-set-content\"\u003eThe Dell PowerEdge R650 supports a vast amount of operating systems. These operating systems include multiple Linux distributions and different versions of VMware ESXi and Windows Server. These operating systems include, but are not limited to:\u003c\/p\u003e\n\u003cul class=\"custom_dots\"\u003e\n\u003cul class=\"custom_dots\"\u003e\n\u003cli\u003e⦿ Red Hat Enterprise Linux 7\u003c\/li\u003e\n\u003cli\u003e⦿ Red Hat Enterprise Linux 8\u003c\/li\u003e\n\u003cli\u003e⦿ Red Hat Enterprise Linux 9\u003c\/li\u003e\n\u003cli\u003e⦿ SuSE Linux ES 15\u003c\/li\u003e\n\u003cli\u003e⦿ Ubuntu Server 20.04 LTS\u003c\/li\u003e\n\u003cli\u003e⦿ VMware ESXi 6.7\u003c\/li\u003e\n\u003cli\u003e⦿ VMware ESXi 7.0\u003c\/li\u003e\n\u003cli\u003e⦿ VMware ESXi 8.0\u003c\/li\u003e\n\u003cli\u003e⦿ Window Server 2016\u003c\/li\u003e\n\u003cli\u003e⦿ Window Server 2019 LTSC\u003c\/li\u003e\n\u003cli\u003e⦿ Window Server 2022 LTSC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cp\u003eOther operating systems are supported, but these are the ones that are specifically tested by Dell.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cloud Ninjas","offers":[{"title":"Default Title","offer_id":48026221707481,"sku":"Dell-R650-10B-SFF","price":6238.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/R650WebsitePhoto.png?v=1772024100","url":"https:\/\/www.aloinfo.com.co\/products\/dell-poweredge-r650-server","provider":"aloinfousa.com","version":"1.0","type":"link"}