{"product_id":"cisco-iem-3300-8t-expansion-module-2oj9h","title":"Cisco IEM-3300-8T Expansion Module","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\u003cli\u003eExpansion module\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eGigabit Ethernet x 8\u003c\/li\u003e\n\u003cli\u003efor Catalyst IE3300 Rugged Series\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"502\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eProperties\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eCisco IEM-3300-8T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eDescription\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eCatalyst IE3300 with 8 GE Copper ports, Expansion Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eIndustrial Ethernet 3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEthernet Switch Expansion Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\" width=\"502\"\u003eSwitches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eTotal ports on expansion module\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eCopper (RJ45)\u003cbr data-mce-fragment=\"1\"\u003e10\/100\/1000Mbps\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eSFP\u003cbr data-mce-fragment=\"1\"\u003e100\/1000Mbps\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eCopper (RJ45)\u003cbr data-mce-fragment=\"1\"\u003e1GE\/2.5G (with up to 802.3bt type 4 PoE)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eTotal system ports (including expansion module)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003ePoE \/ PoE (+) budget\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eDimensions (HxWxD) Inches\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003e6 in. X 2.6 in. X 5.3 in.\u003cbr data-mce-fragment=\"1\"\u003e15.2 cm. x 6.6 cm. x 13.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003e2.0 lbs (0.91 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties][specifications]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"753\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eSpecifications\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eIEM-3300-8T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e6W (Power consumption for non PoE supported model is measured at 12V and for the PoE supported model is measured at 54V.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e-40°C to +70°C (40 LFM vented enclosure)\u003cbr data-mce-fragment=\"1\"\u003e-40°C to +60°C (sealed enclosure)\u003cbr data-mce-fragment=\"1\"\u003e-34°C to +75°C (Min. 200 LFM fan or blower-equipped enclosure)\u003cbr data-mce-fragment=\"1\"\u003e+85°C (type tested for 16 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eUp to 15,000 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eStorage Altitude\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e15,000 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eMean Time Between Failures (MTBF)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e3,041,040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eIndustrial Automation Control\u003cbr data-mce-fragment=\"1\"\u003eSystem\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eIEC 62443-4-1\u003cbr data-mce-fragment=\"1\"\u003eIEC 62443-4-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eElectromagnetic emissions\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eFCC 47 CFR Part 15 subpart B Class A\u003cbr data-mce-fragment=\"1\"\u003eEN 55032\/CISPR 32 Class A\u003cbr data-mce-fragment=\"1\"\u003eVCCI Class A\u003cbr data-mce-fragment=\"1\"\u003eAS\/NZS CISPR 32 Class A\u003cbr data-mce-fragment=\"1\"\u003eCISPR 11 Class A\u003cbr data-mce-fragment=\"1\"\u003eICES 003 Class A\u003cbr data-mce-fragment=\"1\"\u003eCNS 13438 Class A\u003cbr data-mce-fragment=\"1\"\u003eKN 32 Class A\u003cbr data-mce-fragment=\"1\"\u003eEN 300 386\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eElectromagnetic immunity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eCISPR 24\u003cbr data-mce-fragment=\"1\"\u003eEN 55024\u003cbr data-mce-fragment=\"1\"\u003eKN 35\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-4-2 Electro Static Discharge (air 15kV, contact 8kV)\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-4-3 Radiated RF (10V\/m UTP, 20V\/m STP)\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-4-4 Electromagnetic Fast Transients (4kV)\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-4-5 Surge (2KV\/1KV Power, 4KV STP)\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-4-6 Conducted RF (10Vrms UTP)\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-4-10 Damped Oscillatory Magnetic Field (100 A\/m)\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-4-16 Conducted CM Disturbances (30V, Cont\/300V, 1 sec)\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-4-17 Ripple Immunity DC Power (10%)\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-4-18 Damped Oscillatory Wave (2.5kV, 1MHz)\u003cbr data-mce-fragment=\"1\"\u003eEN-61000-4-29 DC Voltage Dips and interruptions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eIndustry standards\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eEN 61000-6-2 Industrial Immunity\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-6-4 Industrial Emissions\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-6-1 Light Industrial Immunity\u003cbr data-mce-fragment=\"1\"\u003eEN 61326-1 Measurement, Control and Laboratory Equipment\u003cbr data-mce-fragment=\"1\"\u003eIEEE 1613 Electric Power Stations Communications Networking\u003cbr data-mce-fragment=\"1\"\u003eEN\/IEC 61850-3 Electric Substations Communications Networking\u003cbr data-mce-fragment=\"1\"\u003eEN50121-4 Railway Signaling and Telecommunications Apparatus\u003cbr data-mce-fragment=\"1\"\u003eEN50155- Railway applications - Rolling stock\u003cbr data-mce-fragment=\"1\"\u003eODVA Industrial EtherNet\/IP\u003cbr data-mce-fragment=\"1\"\u003eNEMA TS 2-2016\u003cbr data-mce-fragment=\"1\"\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMarine I\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eDNC Certification according to class guideline DNV-CG-0339\u003cbr data-mce-fragment=\"1\"\u003eAdditional Standards:\u003cbr data-mce-fragment=\"1\"\u003eIEC 60945, IACS UR E10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eSafety standards and\u003cbr data-mce-fragment=\"1\"\u003ecertifications\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eInformation technology equipment:\u003cbr data-mce-fragment=\"1\"\u003eUL\/CSA 60950-1, IEC 60950-1 CB with all country deviations\u003cbr data-mce-fragment=\"1\"\u003eUL\/CSA 62368-1, IEC 62368-1 CB with all country deviations\u003cbr data-mce-fragment=\"1\"\u003eIndustrial floor (control equipment):\u003cbr data-mce-fragment=\"1\"\u003eUL\/CSA 61010-2-201\u003cbr data-mce-fragment=\"1\"\u003eCB report and certificate to IEC\/EN 61010-2-201\u003cbr data-mce-fragment=\"1\"\u003eHazardous locations:\u003cbr data-mce-fragment=\"1\"\u003eUL121201 (Class l, Div 2, groups A-D)\u003cbr data-mce-fragment=\"1\"\u003eCSA 213 (Class l, Div 2, groups A-D)\u003cbr data-mce-fragment=\"1\"\u003eUL\/CSA 60079-0, -15 (Class l, Zone 2, Gc\/IIC)\u003cbr data-mce-fragment=\"1\"\u003eIEC 60079-0, -15 IECEx test report (Class l, Zone 2, Gc\/IIC)\u003cbr data-mce-fragment=\"1\"\u003eEN 60079-0, -15 ATEX certificate (Class l, Zone 2, Gc\/IIC) Cabinet enclosure required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eHumidity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eRelative humidity of 5% to 95% non-condensing\u003cbr data-mce-fragment=\"1\"\u003eIEC 60068-2-78\u003cbr data-mce-fragment=\"1\"\u003eIEC 60068-2-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eShock and vibration\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eIEC 60068-2-27 (operational shock, 50G, 3ms, half sine)\u003cbr data-mce-fragment=\"1\"\u003eIEC 60068-2-27 (non-operational shock, 65-80G, 9ms, trapezoidal)\u003cbr data-mce-fragment=\"1\"\u003eMIL-STD-810, Method 514.4\u003cbr data-mce-fragment=\"1\"\u003eIEC 60068-2-6 (vibration-sinusiodal, 5Hz-150Hz)\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eCorrosion\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eIEC 60068-2-52 (salt fog)\u003cbr data-mce-fragment=\"1\"\u003eIEC 60068-2-60 (flowing mixed gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications][accesories]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"449\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\" width=\"449\"\u003eAccessories and License Upgrade PIDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"177\"\u003eSTK-RACK-DINRAIL\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e19 in. DIN Rail mount kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\" width=\"449\"\u003eIE-3300 Series Power Supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"177\"\u003ePWR-IE50W-AC\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e50W AC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"177\"\u003ePWR-IE50W-AC-IEC=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e50W AC-IEC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"177\"\u003ePWR-IE50W-AC-L\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e50W AC-L Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"177\"\u003ePWR-IE65W-PC-AC\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e65W PC-AC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"177\"\u003ePWR-IE65W-PC-DC\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e65W PC-DC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"177\"\u003ePWR-IE170W-PC- AC\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e170W PC-AC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"177\"\u003ePWR-IE170W-PC- DC\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e170W PC-DC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"177\"\u003ePWR-IE240W-PCAC-L\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e240W PCAC-L Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"177\"\u003ePWR-IE480W-PCAC-L\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e480W PCAC-L Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\" width=\"449\"\u003e*Expansion modules require an additional power supply separate from the main module's power supply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2\u003eCisco IEM-3300-8T Expansion Module\u003c\/h2\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThe expansion modules of the Cisco Catalyst IE3300 Rugged Series are specifically designed to be used alongside IE3300 and IE3400 base switches. These modules operate on the Cisco IOS XE operating system, the next-gen system incorporating built-in security features. The modules can be managed through various tools, such as Cisco DNA Center and a user-friendly WebUI. The Cisco IEM-3300-8T comes with eight copper ports that can expand the port number to 26 depending on the switch model.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eKey Features:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-preserver-spaces=\"true\"\u003e8 GE Copper ports\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-preserver-spaces=\"true\"\u003eZero-configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-preserver-spaces=\"true\"\u003eIPv6 Ready Logo Certified\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThe tabs contain the Cisco IEM-3300-8T datasheet with all the specifics you need.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"position: absolute; visibility: hidden; left: 51.9792px; top: 3270.09px; width: 507.4px; height: 89.1898px;\" id=\"gtx-anchor\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"visibility: visible; left: 32px; top: 3098px; opacity: 1;\" aria-describedby=\"bubble-5\" role=\"alertdialog\" class=\"jfk-bubble gtx-bubble\"\u003e\n\u003cdiv id=\"bubble-5\" class=\"jfk-bubble-content-id\"\u003e\n\u003cdiv style=\"min-width: 200px; max-width: 400px;\" id=\"gtx-host\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"button\" aria-label=\"Close\" class=\"jfk-bubble-closebtn-id jfk-bubble-closebtn\" tabindex=\"0\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"left: 293.488px;\" class=\"jfk-bubble-arrow-id jfk-bubble-arrow jfk-bubble-arrowdown\"\u003e\n\u003cdiv class=\"jfk-bubble-arrowimplbefore\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"jfk-bubble-arrowimplafter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cisco","offers":[{"title":"Default Title","offer_id":48013268943065,"sku":"IEM-3300-8T-NEW","price":1068.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/iem-3300-8t_1_06300288-9632-402d-9be7-38c5927078a2.webp?v=1771853018","url":"https:\/\/www.aloinfo.com.co\/products\/cisco-iem-3300-8t-expansion-module-2oj9h","provider":"aloinfousa.com","version":"1.0","type":"link"}