{"product_id":"fluke-373-true-rms-ac-clamp-meter-fnqd3","title":"Fluke 373 True-RMS AC Clamp Meter","description":"\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"586\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"169\"\u003eProperties\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"417\"\u003eFluke 373 True-RMS AC Clamp Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"169\"\u003eDescription\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"417\"\u003eThe Fluke 373 True-RMS AC Clamp Meter offers precise AC current measurements up to 600 A and AC voltage readings up to 600V, along with DC voltage measurements up to 600 V and resistance measurements up to 6000 Ω. With a large backlit display and automatic range selection, it ensures ease of use and accurate results for various applications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"169\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"417\"\u003eFluke Clamp Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"169\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"417\"\u003eClamp Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"169\"\u003eUseful capabilities\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"417\"\u003eProvides True-RMS voltage and current measurements to accurately measure non-linear signals\u003cbr data-mce-fragment=\"1\"\u003eAutomatically selects a measurement range based on voltage present so you don’t need to change the switch positions while taking a measurement\u003cbr data-mce-fragment=\"1\"\u003ePresents readings on a large, easy-to-read backlit display\u003cbr data-mce-fragment=\"1\"\u003eFeatures CAT IV 300 V, CAT III 600 V safety ratings\u003cbr data-mce-fragment=\"1\"\u003eComes with a soft carrying case \u003cbr data-mce-fragment=\"1\"\u003eRuns on two AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"169\"\u003eWhat's in the box\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"417\"\u003e• 373 True-RMS AC Clamp Meter\u003cbr data-mce-fragment=\"1\"\u003e• (1 pair TL75 test leads\u003cbr data-mce-fragment=\"1\"\u003e• Soft carrying case\u003cbr data-mce-fragment=\"1\"\u003e• Five AA Alkaline Batteries (Installed\u003cbr data-mce-fragment=\"1\"\u003e• Quick Reference Guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties] [specifications]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"475\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center;\" width=\"475\" colspan=\"2\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center;\" colspan=\"2\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center;\" colspan=\"2\"\u003eAC Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRange\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e600.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eResolution\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e2 % ± 5 digits (48 – 62 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eCrest Factor (50\/60 Hz\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e2.5 @ 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center;\" colspan=\"2\"\u003eAC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRange\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"320\"\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eResolution\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1.0 % ± 5 digits (48 – 62 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center;\" colspan=\"2\"\u003eDC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRange\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"320\"\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eResolution\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1 % ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center;\" colspan=\"2\"\u003eResistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRange\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e600.0 Ω\/6000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eResolution\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0.1 Ω\/1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1 % ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eContinuity Beeper\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e30 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center;\" colspan=\"2\"\u003eCapacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRange\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e10.0 – 100.0 μF \/ 1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eResolution\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0.1 μF\/1 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1.9 % ± 2 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center;\" colspan=\"2\"\u003eMechanical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSize (L x W x H\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e232 mm x 85 mm x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e370 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center;\" colspan=\"2\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e-10 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStorage Temp\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e-40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" rowspan=\"5\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"320\" rowspan=\"5\"\u003eNon condensing (\u0026lt; 10 °C\u003cbr data-mce-fragment=\"1\"\u003e≤ 90 % RH (at 10 °C to 30 °C\u003cbr data-mce-fragment=\"1\"\u003e≤ 75 % RH (at 30 °C to 40 °C\u003cbr data-mce-fragment=\"1\"\u003e≤ 45 % RH (at 40 °C to 50 °C\u003cbr data-mce-fragment=\"1\"\u003e(Without Condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e3000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStorage Altitude\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e12,000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEMI, EMC\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMeets all applicable requirements in EN61326-1:2006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eTemperature Coefficients\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAdd 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" rowspan=\"6\"\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"320\" rowspan=\"6\"\u003eANSI\/ISA S82.02.01:2004\u003cbr data-mce-fragment=\"1\"\u003eCAN\/CSA-C22.2 No. 61010-1-04\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61010-1:2001, 600V CAT III, 300V CAT IV\u003cbr data-mce-fragment=\"1\"\u003ePollution Degree 2\u003cbr data-mce-fragment=\"1\"\u003eEN\/IEC 61010-2-32:2002\u003cbr data-mce-fragment=\"1\"\u003eEN\/IEC 61010-031:2002\/A1:2008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eBatteries\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e2 AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications] [accesories]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"771\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center;\" width=\"771\" colspan=\"2\"\u003eOptional Accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eCases and holsters\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e•Fluke C550 Tool Bag\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eTest leads, probes and clips \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"499\"\u003e• Fluke AC220 SureGrip™ Alligator Clips\u003cbr data-mce-fragment=\"1\"\u003e• Fluke AC87 Heavy Duty Bus Bar Clip Set\u003cbr data-mce-fragment=\"1\"\u003e• Fluke AC89 Heavy Duty Insulation Piercing Test Clip\u003cbr data-mce-fragment=\"1\"\u003e• Fluke TL220 SureGrip™ Industrial Test Lead Set\u003cbr data-mce-fragment=\"1\"\u003e• Fluke TL75 Hard Point™ Test Lead Set\u003cbr data-mce-fragment=\"1\"\u003e• Fluke TL175 TwistGuard™ Test Leads\u003cbr data-mce-fragment=\"1\"\u003e• Fluke TP1 Slim Reach Test Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eLight\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"499\"\u003e• Fluke LVD1A Non-Contact Voltage Tester with LED Flashlight\u003cbr data-mce-fragment=\"1\"\u003e• Fluke L206 Deluxe LED Hat Light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eFluke 373 True-RMS AC Clamp Meter\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe Fluke 373 True-RMS AC Clamp Meter is an ideal option for situations requiring AC-only current measurement. It is equipped with True RMS AC voltage and current measurements, allowing AC current measurement up to 600 A and AC voltage up to 600V. Additionally, this product can measure DC voltage up to 600 V and resistance up to 6000 Ω. To enhance usability, the device features a large, easily readable backlit display that improves visibility in low-light conditions. Furthermore, it is designed to automatically set the appropriate measurement range based on the voltage present upon powering up, eliminating the need to adjust the switch during measurement manually.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eQuick Specs:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eMeasures AC and DC voltage to 600V\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eMeasure resistance to 6000 with continuity detection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eA top-performing True-RMS\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eFeatures CAT IV 300 V, CAT III 600 V safety ratings\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003ePlease see the related tabs for the FLUKE-373 datasheet and compatible accessories.\u003c\/span\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":48013016039641,"sku":"FLUKE-373-NEW","price":301.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/FLUKE-373_1_ff364151-ef5b-461b-8181-b3704caaa620.webp?v=1771848523","url":"https:\/\/www.aloinfo.com.co\/pa\/products\/fluke-373-true-rms-ac-clamp-meter-fnqd3","provider":"aloinfousa.com","version":"1.0","type":"link"}