{"product_id":"endress-hauser-absolute-and-gauge-pressure-cerabar-pmp71","title":"Endress+Hauser Absolute And Gauge Pressure Cerabar PMP71","description":"\u003ch1\u003eOverview\u003c\/h1\u003e\u003cp\u003eSpecs at a glance\u003c\/p\u003e\u003cp\u003e * Accuracy ：Standard: 0.05%  Platinum: up to 0.025%\u003cbr\u003e * Process temperature ：-40°C...125°C(-40°F...257°F)\u003cbr\u003e * Pressure measuring range ：400 mbar...700 bar (5.8 psi...10.500 psi)\u003cbr\u003e * Main wetted parts ：Alloy C276；316L；Rhodium\u003cbr\u003e * Material process membrane : 316L, AlloyC;Rhodium\u0026gt; Gold\u003cbr\u003e * Measuring cell : 400 mbar...700 bar(5.8 psi...10.500 psi)\u003cbr\u003e\u003cbr\u003e \u003c\/p\u003e\u003ch1\u003eApplication\u003c\/h1\u003e\u003cp\u003eThe Cerabar PMP71 digital pressure transmitter with metallic membrane is typically used in process applications for pressure,level, volume or mass measurement in liquids or gases. PMP71 is designed for high pressure applications up to 700bar. Quick Setup with freely adjustable measuring range without pressure specification. Designed according to IEC 61508 for use in SIL2\/3 safety systems and available with MID Parts Certificate suitable for custody transfer applications.\u003cbr\u003e\u003cbr\u003eTwo chamber aluminum or stainless steel (316L) housing.\u003cbr\u003e* Process connections: Threads and flange connections\u003cbr\u003e* Process temperature: -40 to +125°C (-40 to +257°F)\u003cbr\u003e* Measuring ranges: -1\/0 up to 700bar (-15\/0 up to +10,500psi)\u003cbr\u003e* Accuracy: ±0.05%, \"Platinum\" ±0.025%\u003cbr\u003e* International explosion protection certificates, overfill prevention WHG, hygienic approvals, marine approvals, SIL\u003c\/p\u003e\u003ch1\u003eBenefits\u003c\/h1\u003e\u003cp\u003e* Best accuracy, reproducibility and long-term stability\u003cbr\u003e* Highest safety due to gas tight feedthrough with capabilities up to SIL2\/3, certified to IEC 61508\u003cbr\u003e* Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus\u003cbr\u003e* HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics\u003cbr\u003e* Overload-resistant and function-monitored from the measuring cell to the electronics\u003cbr\u003e* Available with mounted manifolds: always fit, always tested for leaks\u003cbr\u003e* Seamless and independent system integration (HART\/PA\/FF)\u003c\/p\u003e\u003ch1\u003eSpecification\u003c\/h1\u003e\u003cfigure class=\"table\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eitem\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003evalue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCustomized support\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePlace of Origin\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eBrand Name\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eEndress+Hauser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eModel Number\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCerabar PMP71\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasuring Principle\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAbsolute and gauge pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCharacteristic\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDigital transmitter with piezoresistive sensor and welded metallic membrane \u003cbr\u003eModular transmitter \u003cbr\u003eLong term stability \u003cbr\u003eEnhanced safety via self diagnostic functionsSecondary process barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4...20 mA HART \u003cbr\u003e10,5...45V DC (Non Ex): \u003cbr\u003eEx ia: 10,5...30V DC \u003cbr\u003ePROFIBUS PA: \u003cbr\u003e9...32 V DC (Non Ex) \u003cbr\u003eFOUNDATION Fieldbus: \u003cbr\u003e9...32 V DC (Non Ex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eReference Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eStandard: 0.05% \u003cbr\u003ePlatinum: up to 0.025%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eLong Term Stability\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e0.05 % of URL\/ year \u003cbr\u003e0.07 % of URL\/ 5 years \u003cbr\u003e0.1 % of URL\/ 10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProcess Temperature\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e-40°C...125°C \u003cbr\u003e(-40°F...257°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e-50°C...85°C \u003cbr\u003e(-58°F...185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasuring Cell\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e400 mbar...700 bar \u003cbr\u003e(5.8 psi...10.500 psi) \u003cbr\u003erelative\/ absolute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSmallest Calibratable Span\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e5 mbar (0.075 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVacuum Resistance\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e10 mbar (0.15 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMax. Turn Down\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e100:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMax. Overpressure Limit\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e1050 bar (15.750 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProcess Connection\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eThread: \u003cbr\u003eG1\/2...G2, R1\/2, MNPT1\/2...MNPT2, R1\/2 \u003cbr\u003eFlange: \u003cbr\u003eDN25...DN80, \u003cbr\u003eASME 1\"...4\", \u003cbr\u003eJIS 10K...20K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMaterial Process Membrane\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e316L, AlloyC, \u003cbr\u003eRhodium\u0026gt; Gold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMaterial Gasket\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eNone, measuring cell welded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFill Fluid\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSilicone oil, \u003cbr\u003eInert oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMaterial Housing\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDie-cast aluminum, \u003cbr\u003eAISI 316L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCommunication\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4...20 mA HART \u003cbr\u003e1- 5V DC Low Power \u003cbr\u003ePROFIBUS PA \u003cbr\u003eFOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCertificates \/ Approvals\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eATEX, FM, CSA, CSA C\/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC, UK Ex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSafety Approvals\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDesign Approvals\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eEN10204-3.1 \u003cbr\u003eNACE MR0175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMarine Approvals\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eGL\/ABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDrinking Water Approvals\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eNSF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSpecialities\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDiagnostic functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSuccessor\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePMP71B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/figure\u003e\u003cp\u003e \u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":48020380090585,"sku":null,"price":1037.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/Endress_Hauser_Absolute_And_Gauge_Pressure_Cerabar_PMP71.png?v=1771970810","url":"https:\/\/www.aloinfo.com.co\/en\/products\/endress-hauser-absolute-and-gauge-pressure-cerabar-pmp71","provider":"aloinfousa.com","version":"1.0","type":"link"}