{"product_id":"cisco-iem-3000-4pc-expansion-module-7hjdf","title":"CISCO IEM-3000-4PC Expansion Module","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\u003cli\u003eExpansion module\u003c\/li\u003e\n\u003cli\u003e10\/100 Ethernet x 4\u003c\/li\u003e\n\u003cli\u003efor Industrial Ethernet 3000 Series\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable width=\"509\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"200\"\u003eProperties\u003c\/td\u003e\n\u003ctd width=\"309\"\u003eCisco IEM-3000-4PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"200\"\u003eDescription\u003c\/td\u003e\n\u003ctd width=\"309\"\u003eExpansion PoE module for IE-3000-4TC, IE-3000-8TC, IE-3000-4TC-E, and IE-3000-8TC-E switches, support 4 ports 10\/100 PoE\/PoE+. External power source is required (44-57 VDC for PoE\/50-57 VDC for PoE+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"200\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eIndustrial Ethernet 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"200\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExpansion Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"200\"\u003eConfigurations\u003c\/td\u003e\n\u003ctd width=\"309\"\u003eExpansion PoE\/PoE+ module for Cisco IE-3000-4TC and IE-3000-8TC switches\u003cbr\u003e4 10\/100 PoE\/PoE+ ports\u003cbr\u003eExternal PoE power source (44-57 VDC for PoE\/50-57 VDC for PoE+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"200\"\u003eSupported Products\u003c\/td\u003e\n\u003ctd width=\"309\"\u003eIE-3000-4TC and IE-3000-8TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"200\"\u003eDimensions (HxWxD) Inches\u003c\/td\u003e\n\u003ctd width=\"309\"\u003e3.5W x 5.8H x 4.4D (89mm W x 147mm H x 112mm D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"200\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.4 (1.08 Kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"200\"\u003eInput voltage and currents supported\u003c\/td\u003e\n\u003ctd width=\"309\"\u003e44-57V input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"200\"\u003eMaximum power consumption\u003c\/td\u003e\n\u003ctd width=\"309\"\u003e7.3W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"200\"\u003eMean Time Between Failures (MTBF)\u003c\/td\u003e\n\u003ctd width=\"309\"\u003e1,494,990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties][specifications]\u003c\/p\u003e\n\u003ctable width=\"753\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"384\"\u003eSpecifications\u003c\/td\u003e\n\u003ctd width=\"369\"\u003eIEM-3000-4PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"384\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd width=\"369\"\u003e-40C to +75C\u003cbr\u003e-40C to +70C (Vented Enclosure 40 LFM Air Flow)\u003cbr\u003e-40C to +60C (Sealed Enclosure 0 LFM Air Flow)\u003cbr\u003e-24C to +75C (Fan or Blower equipped Enclosure 200 LFM Air Flow)\u003cbr\u003e-40C to +85C (IEC 60068-2-2 Environmental Type Testing 16 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"384\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"384\"\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd width=\"369\"\u003eUp to 13,000 ft (3963m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"384\"\u003eStorage Altitude\u003c\/td\u003e\n\u003ctd width=\"369\"\u003eUp to 15,000 ft (4573m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"384\"\u003eStandard safety certifications\u003c\/td\u003e\n\u003ctd width=\"369\"\u003eUL 60950-1\u003cbr\u003eCSA C22.2 No. 60950-1\u003cbr\u003eTUV\/GS to EN 60950-1\u003cbr\u003eCB to IEC 60950-1 with all country deviations\u003cbr\u003eNOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"384\"\u003eElectromagnetic emissions\u003c\/td\u003e\n\u003ctd width=\"369\"\u003eFCC Part 15 Class A\u003cbr\u003eEN 55022\u003cbr\u003eCISPR 22\u003cbr\u003eCISPR11\u003cbr\u003eVCCI Class A\u003cbr\u003eAS\/NZS 3548 Class A\u003cbr\u003eCNS 13438 Class A\u003cbr\u003eKN 22 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic immunity\u003c\/td\u003e\n\u003ctd width=\"369\"\u003eEN 55024\u003cbr\u003eAS\/NZS CISPR 24\u003cbr\u003eKN 24\u003cbr\u003eIEC\/EN 61000-4-2 (Electro Static Discharge)\u003cbr\u003eIEC\/EN 61000-4-3 (Radiated Immunity)\u003cbr\u003eIEC\/EN 61000-4-4 (Fast Transients)\u003cbr\u003eIEC\/EN 61000-4-5 (Surge)\u003cbr\u003eIEC\/EN 61000-4-6 (Conducted Immunity)\u003cbr\u003eIEC\/EN 61000-4-8 (Power Frequency Magnetic Field Immunity)\u003cbr\u003eIEC\/EN 61000-4-9 (Pulse Magnetic Field Immunity)\u003cbr\u003eIEC\/EN 61000-4-10 (Oscillatory Magnetic Field Immunity)\u003cbr\u003eIEC\/EN 61000-4-11 (AC power Voltage Immunity)\u003cbr\u003eIEC\/EN 61000-4-16 (Low Frequency Conducted CM Disturbances)\u003cbr\u003eIEC\/EN 61000-4-17 (Ripple on DC Input Power)\u003cbr\u003eIEC\/EN 61000-4-18 (Damped Oscillatory Wave)\u003cbr\u003eIEC\/EN 61000-4-29 (Voltage Dips Immunity, DC power)\u003cbr\u003eIEEE C37.90 (Surge)\u003cbr\u003eIEEE C37.90.1 (Fast Transients)\u003cbr\u003eIEEE C37.90.2 (Radiated Immunity)\u003cbr\u003eIEEE C37.90.3 (Electro Static Discharge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical stability\u003c\/td\u003e\n\u003ctd width=\"369\"\u003eIEC 60628-2-27 Shock 20g (operational), 30g (nonoperational)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustry specifications\u003c\/td\u003e\n\u003ctd width=\"369\"\u003eEN 61131-2 Programmable Controllers (EMC\/EMI, environmental, mechanical)\u003cbr\u003eIEEE 1613 Power Station and Substation Networking Devices\u003cbr\u003eIEC 61850-3 Power Station and Substation Communication Networks and Systems\u003cbr\u003eEN 61326-1 Electrical Equipment for Measurement, Control and Laboratory Use - EMC\u003cbr\u003eEN 61000-6-1 Immunity for Light Industrial Environments\u003cbr\u003eEN 61000-6-2 Immunity for Industrial Environments\u003cbr\u003eEN 61000-6-4 Emissions for Industrial Environments\u003cbr\u003eTS 61000-6-5 EMC Immunity for Power Station and Substation\u003cbr\u003eEN 50155 Railway, Electronic Equipment on Rolling Stock (EMI\/EMC, environmental, mechanical)\u003cbr\u003eEN 50121-3-2 Railway, Electromagnetic Compatibility on Rolling Stock\u003cbr\u003eEN 50121-4 Railway, Emission and Immunity of Signaling and Telecommunications Apparatus\u003cbr\u003eEN 60945 Maritime Navigation and Radio-communication Equipment and Systems\u003cbr\u003eIEC 60533 Shipboard Electrical and Electronic Installation EMC\u003cbr\u003eMarine Type Approval (BV, DNV, Korean Register, Lloyd Register)\u003cbr\u003eNEMA TS-2 (EMC, environmental, mechanical)\u003cbr\u003eABB Industrial IT certification\u003cbr\u003eODVA Industrial EtherNet\/IP support\u003cbr\u003ePROFINETv2 support\u003cbr\u003eDirective 2011\/65\/EU RoHS\u003cbr\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous locations\u003c\/td\u003e\n\u003ctd width=\"369\"\u003eUL\/CSA 60079-0, -15 (Class 1, Div 2 A-D) (requires cabinet enclosure)\u003cbr\u003eEN 60079-0, -15 ATEX Certification (Class 1, Zone 2 A-D) (requires cabinet enclosure)\u003cbr\u003eIEC 60079-0, -15 (Test report only) (requires cabinet enclosure)\u003cbr\u003eUL 508\u003cbr\u003eCSA C22.2 No. 142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"384\"\u003eHumidity\u003c\/td\u003e\n\u003ctd width=\"369\"\u003eRelative humidity: 5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\u003ch2\u003eCISCO IEM-3000-4PC Expansion Module\u003c\/h2\u003e\n\u003cp\u003eThe Cisco Industrial Ethernet 3000 series (IE 3000 series) is a family of Layer 2 and Layer 3 switches that bring Cisco's leadership in switching to Industrial Ethernet applications with Innovative features, robust security, and superior ease of use. The Cisco IE 3000 Series is an ideal product for Industrial Ethernet applications, including factory automation, energy and process control, and intelligent transportation systems (ITSs).\u003c\/p\u003e","brand":"Cisco","offers":[{"title":"Default Title","offer_id":48013312917721,"sku":"IEM-3000-4PC-NEW","price":810.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/IEM-3000-4PC_690b9697-7522-460f-8467-a95daa817d49.jpg?v=1771853904","url":"https:\/\/www.aloinfo.com.co\/en\/products\/cisco-iem-3000-4pc-expansion-module-7hjdf","provider":"aloinfousa.com","version":"1.0","type":"link"}