{"product_id":"fluke-772-milliamp-process-clamp-meter-fluke-772","title":"Fluke 772 Milliamp Process Clamp Meter (FLUKE-772","description":"\u003cp\u003e[shortdesc]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 772 Milliamp Process Clamp Meter measures 4-20 mA current without breaking the loop. Features include signal sourcing, simulation, and loop power, ideal for process control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"1390\" style=\"border-collapse: collapse; width: 1043pt;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"701\" style=\"width: 526pt;\"\u003e \u003ccol width=\"689\" style=\"mso-width-source: userset; mso-width-alt: 24064; width: 517pt;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"25\" style=\"height: 18.5pt;\"\u003e\n\u003ctd height=\"25\" class=\"xl65\" width=\"701\" style=\"height: 18.5pt; width: 526pt;\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"689\" style=\"width: 517pt;\"\u003eFluke 772 Milliamp Process Clamp Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"26\" style=\"mso-height-source: userset; height: 19.5pt;\"\u003e\n\u003ctd height=\"26\" class=\"xl65\" style=\"height: 19.5pt;\"\u003eProduct Description\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003eMeasures 4-20 mA current without breaking the loop. Features include signal sourcing, simulation, and loop power, ideal for process control.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"25\" style=\"height: 18.5pt;\"\u003e\n\u003ctd height=\"25\" class=\"xl65\" style=\"height: 18.5pt;\"\u003eType\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003eProcess Clamp Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"25\" style=\"height: 18.5pt;\"\u003e\n\u003ctd height=\"25\" class=\"xl65\" style=\"height: 18.5pt;\"\u003eCompatibility\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003e4 to 20 mA Control Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"25\" style=\"height: 18.5pt;\"\u003e\n\u003ctd height=\"25\" class=\"xl65\" style=\"height: 18.5pt;\"\u003eMedia Type\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003eProcess Control Applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"25\" style=\"height: 18.5pt;\"\u003e\n\u003ctd height=\"25\" class=\"xl65\" style=\"height: 18.5pt;\"\u003ePower\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003e4 x 1.5 V Alkaline (IEC LR6 batteries, 12 hours in mA source into 500 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"25\" style=\"height: 18.5pt;\"\u003e\n\u003ctd height=\"25\" class=\"xl65\" style=\"height: 18.5pt;\"\u003eSize\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003e44 x 70 x 246 mm (2 7\/8 x 5 ¾ x 11 5\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"25\" style=\"height: 18.5pt;\"\u003e\n\u003ctd height=\"25\" class=\"xl65\" style=\"height: 18.5pt;\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003e410 g (14.4 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"25\" style=\"height: 18.5pt;\"\u003e\n\u003ctd height=\"25\" class=\"xl65\" style=\"height: 18.5pt;\"\u003eDurability\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003eRugged construction with IP40 rating and 1-meter drop test certification (except the jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"25\" style=\"height: 18.5pt;\"\u003e\n\u003ctd height=\"25\" class=\"xl65\" style=\"height: 18.5pt;\"\u003eOperating Conditions\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003e-10°C to 50°C; \u0026lt; 90% humidity below 30°C, \u0026lt; 75% humidity at 30–55°C; 0 to 2000 m altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"25\" style=\"height: 18.5pt;\"\u003e\n\u003ctd height=\"25\" class=\"xl65\" style=\"height: 18.5pt;\"\u003eStorage Conditions\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003e-25°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"25\" style=\"height: 18.5pt;\"\u003e\n\u003ctd height=\"25\" class=\"xl65\" style=\"height: 18.5pt;\"\u003eIP Rating\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003eIP 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"25\" style=\"height: 18.5pt;\"\u003e\n\u003ctd height=\"25\" class=\"xl65\" style=\"height: 18.5pt;\"\u003eVibration\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003eRandom 2 g, 5 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"25\" style=\"height: 18.5pt;\"\u003e\n\u003ctd height=\"25\" class=\"xl65\" style=\"height: 18.5pt;\"\u003eShock\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003e1 meter drop test (except the jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e [\/properties] \u003c\/p\u003e\n\u003cp\u003e[specifications]\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 1040pt;\" width=\"1387\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 446pt;\" width=\"595\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 27648; width: 594pt;\" width=\"792\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt; width: 446pt;\" width=\"595\" class=\"xl67\" height=\"25\"\u003eDiameter of measurable conductor\u003c\/td\u003e\n\u003ctd style=\"width: 594pt;\" width=\"792\" class=\"xl68\"\u003e0.177” (4.5 mm max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt;\" class=\"xl67\" height=\"25\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd class=\"xl68\"\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt;\" class=\"xl67\" height=\"25\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd class=\"xl68\"\u003e-25°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt;\" class=\"xl67\" height=\"25\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd class=\"xl68\"\u003e\u0026lt; 90% @ \u0026lt;30°C; \u0026lt; 75% @ 30 to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt;\" class=\"xl67\" height=\"25\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd class=\"xl68\"\u003e0 to 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt;\" class=\"xl67\" height=\"25\"\u003eIP rating\u003c\/td\u003e\n\u003ctd class=\"xl68\"\u003eIP 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt;\" class=\"xl65\" height=\"25\"\u003eSize\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003e44 x 70 x 246 mm (2 7\/8 x 5 ¾ x 11 5\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt;\" class=\"xl65\" height=\"25\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003e410 g (14.4 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt;\" class=\"xl65\" height=\"25\"\u003eVibration\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003eRandom 2 g, 5 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt;\" class=\"xl65\" height=\"25\"\u003eShock\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003e1 meter drop test (except the jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt;\" class=\"xl65\" height=\"25\"\u003eEMI\/RFI\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003eMeets EN61326-1; for current measurement with jaw, add 1 mA to specification for EMC field strengths of 1 V\/m up to 3 V\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt;\" class=\"xl65\" height=\"25\"\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003e0.01%\/°C (\u0026lt; 18°C or \u0026gt; 28°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt;\" class=\"xl65\" height=\"25\"\u003ePower\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003e(4 AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt;\" class=\"xl65\" height=\"25\"\u003emA measurement (measured by clamp\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003eResolution\/Range: 0 to 20.99 mA; Accuracy: 0.2% + 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt;\" class=\"xl65\" height=\"25\"\u003emA measurement (21.0 mA to 100.0 mA\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003eResolution\/Range: 21.0 mA to 100.0 mA; Accuracy: 1% + 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt;\" class=\"xl65\" height=\"25\"\u003emA measurement (measured in series\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003eResolution\/Range: 0 to 24.00 mA; Accuracy: 0.2% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt;\" class=\"xl65\" height=\"25\"\u003emA source\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003eResolution\/Range: 0 to 24.00 mA; Accuracy: 0.2% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt;\" class=\"xl65\" height=\"25\"\u003emA simulate\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003eResolution\/Range: 0 to 24.00 mA; Accuracy: 0.2% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt;\" class=\"xl65\" height=\"25\"\u003eLoop power\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003e24 V for powering field devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt;\" class=\"xl65\" height=\"25\"\u003eSignal Sourcing\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003eSources 4 to 20 mA signals to test control system inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt;\" class=\"xl65\" height=\"25\"\u003eSimulation Capabilities\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003eSimulates 4 to 20 mA signals for system diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt;\" class=\"xl65\" height=\"25\"\u003eMin\/Max Recording\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003eCaptures fluctuations in current for precise troubleshooting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt;\" class=\"xl65\" height=\"25\"\u003eDisplay\u003c\/td\u003e\n\u003ctd class=\"xl66\"\u003eBacklit digital LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\u003ch1\u003eFluke 772 Milliamp Process Clamp Loop Meter\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 772 Milliamp Process Clamp Loop Meter is a versatile tool designed for professionals working with 4 to 20 mA control systems. It provides a non-intrusive way to measure current without breaking the loop and includes advanced features like signal sourcing, simulation, and loop power testing, making it an essential instrument for troubleshooting and verifying process control systems.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Intrusive Measurement:\u003c\/strong\u003e Measures 4 to 20 mA signals without breaking the loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Sourcing:\u003c\/strong\u003e Sources 4 to 20 mA signals to test control system inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimulation Capabilities:\u003c\/strong\u003e Simulates 4 to 20 mA signals for system diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Power:\u003c\/strong\u003e Provides 24 V loop power to test transmitters in real-time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMin\/Max Recording:\u003c\/strong\u003e Captures fluctuations in current for precise troubleshooting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eErgonomic Design:\u003c\/strong\u003e Compact and easy to use with a backlit display for low-light conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurability:\u003c\/strong\u003e Rugged construction with IP40 rating and 1-meter drop test certification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003emA Measurement:\u003c\/strong\u003e 0 to 24 mA, accuracy ±0.2% + 2 counts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003emA Source\/Simulate:\u003c\/strong\u003e 0 to 24 mA with accuracy ±0.2% + 2 counts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Power:\u003c\/strong\u003e 24 V for powering field devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Backlit digital LCD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e 4 x 1.5 V Alkaline (IEC LR6 batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -10°C to 50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 248 x 76 x 41 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1 lb\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":48007435976921,"sku":"FLUKE-772-NEW","price":1438.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/127_1.jpg?v=1771682230","url":"https:\/\/www.aloinfo.com.co\/bn\/products\/fluke-772-milliamp-process-clamp-meter-fluke-772","provider":"aloinfousa.com","version":"1.0","type":"link"}